Browse > Article
http://dx.doi.org/10.3344/kjp.2015.28.4.287

Ultrasound-guided Continuous Axillary Brachial Plexus Block Using a Nerve Stimulating Catheter: EpiStim Catheter  

Choi, Sang Sik (Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, Korea University College of Medicine)
Lee, Mi Kyoung (Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, Korea University College of Medicine)
Kim, Jung Eun (Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, Korea University College of Medicine)
Kim, Se Hee (Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, Korea University College of Medicine)
Yeo, Gwi Eun (Department of Anesthesiology and Pain Medicine, Korea University Guro Hospital, Korea University College of Medicine)
Publication Information
The Korean Journal of Pain / v.28, no.4, 2015 , pp. 287-289 More about this Journal
Abstract
Brachial plexus block (BPB) under ultrasound guidance has come to be widely used. However, nerve injury has been reported following ultrasound-guided BPB. We hypothesized that BPB under ultrasound guidance in conjunction with real-time electrical nerve stimulation would help us prevent nerve injury and do more successful procedure. Here, we report the successful induction and maintenance of ultrasound-guided BPB and the achievement of good peri- and postoperative pain control using a conductive catheter, the EpiStim$^{(R)}$.
Keywords
Brachial plexus blocks; Catheters; Pain management; Peripheral nerve; Radial nerve; Ultrasonography;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chan VW, Peng PW, Kaszas Z, Middleton WJ, Muni R, Anastakis DG, et al. A comparative study of general anesthesia, intravenous regional anesthesia, and axillary block for outpatient hand surgery: clinical outcome and cost analysis. Anesth Analg 2001; 93: 1181-4.   DOI
2 Imasogie N, Ganapathy S, Singh S, Armstrong K, Armstrong P. A prospective, randomized, double-blind comparison of ultrasound-guided axillary brachial plexus blocks using 2 versus 4 injections. Anesth Analg 2010; 110: 1222-6.
3 Bernucci F, Gonzalez AP, Finlayson RJ, Tran DQ. A prospective, randomized comparison between perivascular and perineural ultrasound-guided axillary brachial plexus block. Reg Anesth Pain Med 2012; 37: 473-7.   DOI
4 Tran DQ, Pham K, Dugani S, Finlayson RJ. A prospective, randomized comparison between double-, triple-, and quadruple-injection ultrasound-guided axillary brachial plexus block. Reg Anesth Pain Med 2012; 37: 248-53.   DOI
5 Chan VW, Perlas A, McCartney CJ, Brull R, Xu D, Abbas S. Ultrasound guidance improves success rate of axillary brachial plexus block. Can J Anaesth 2007; 54: 176-82.   DOI
6 Jung MJ, Byun HY, Lee CH, Moon SW, Oh MK, Shin H. Medial antebrachial cutaneous nerve injury after brachial plexus block: two case reports. Ann Rehabil Med 2013; 37: 913-8.   DOI
7 Asheghan M, Khatibi A, Holisaz MT. Paresthesia and forearm pain after phlebotomy due to medial antebrachial cutaneous nerve injury. J Brachial Plex Peripher Nerve Inj 2011; 6: 5.
8 Yildiz N, Ardic F. A rare cause of forearm pain: anterior branch of the medial antebrachial cutaneous nerve injury:a case report. J Brachial Plex Peripher Nerve Inj 2008; 3:10.
9 Reiss W, Kurapati S, Shariat A, Hadzic A. Nerve injury complicating ultrasound/electrostimulation-guided supraclavicular brachial plexus block. Reg Anesth Pain Med 2010; 35: 400-1.   DOI
10 Barrington MJ, Watts SA, Gledhill SR, Thomas RD, Said SA, Snyder GL, et al. Preliminary results of the Australasian Regional Anaesthesia Collaboration: a prospective audit of more than 7000 peripheral nerve and plexus blocks for neurologic and other complications. Reg Anesth Pain Med 2009; 34: 534-41.   DOI