• 제목/요약/키워드: Ultrasonography imaging

검색결과 540건 처리시간 0.028초

Diagnosis and Therapy of Primary Hepatic Neuroendocrine Carcinoma: Clinical Analysis of 10 Cases

  • Wang, Li-Ming;An, Song-Lin;Wu, Jian-Xiong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권6호
    • /
    • pp.2541-2546
    • /
    • 2014
  • Background: Primary hepatic neuroendocrine carcinoma (PHNEC) is rarer than extrahepatic gastrointestinal neuroendocrine carcinoma (NEC). It is difficult to make a correct diagnosis and poses a challenge for management. Materials and Methods: Ten PHNEC patients were admitted to our hospital from June 2006 to June 2011. Laboratory tests and imaging scans were performed for diagnosis and exclusion of extrahepatic NEC. All patients were AFP - and CA199-. Seven patients had solid tumors with cystic changes on ultrasonography, CT and/or MRI. For the initial treatment, four patients received combined-therapy and six monotherapy. Considering overall treatment, six patients received combined-therapy and four patients monotherapy. Staging criteria of primary hepatocellular carcinoma (PHC, AJCC 7th edition) were used to differentiate the stage of all patients: 3 patients were stage I, 2 stageII, 4 patients stageIII and 1 stageIV. All patients were followed up and clinical data were gathered. Results: The median follow-up duration was 38.5 months. The 1-year, 2-year, 3-year and 6-year disease-free survival was 80.0%, 46.2% and 46.2% and 0% respectively. The overall survival rates were 100%, 67.1%, 67.1% and 33.6% respectively. Patients in early-stages (I/II) had similar disease-free and overall survival as those in advanced-stages (III/IV). Patients with monotherapy had significant shorter disease-free and overall survival than the patients with combination-therapy. Conclusions: PHNEC has a unique specificity during its occurrence and development. The staging criteria of PHC might not be suitable for the PHENT. More convenient and effective features need to be found in imaging and laboratory detection. Surgical resection, TACE, chemotherapy and radiofrequency ablation should be performed in combination and actively for patients with PHNEC or recurrence to get the best effectiveness; they might extend the disease-free and overall survival.

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

진단 영상을 위주로한 간외 담도계 질환 3례 (Three Cases of Extrahepatic Bile Duct Disorder: Diagnostic Imaging in Perspective)

  • 임창윤;정유철;오선경;정주현;김소희;김남향;서경원;황철용;변예은;권오경;최민철;윤정희
    • 한국임상수의학회지
    • /
    • 제22권4호
    • /
    • pp.412-416
    • /
    • 2005
  • Three cases of extrahepatic bile duct disorder were presented. Two cases, a dog and a cat, were related to the obstruction of the extrhepatic bile duct, the other dog was affected with the gall bladder rupture. The clinical signs included anorexia, abdominal distension and vomiting. The laboratory test represented increased hepatic enzymes. On the radiography, hepatomegaly was seen in the obstructive cases, and ascites could be seen in the ruptured case. On the Ultrasonography, dilated gall bladder and extrahepatic bile duct were found in the obstructive cases, and there were ascites, indistinct gall bladder wall, dilation of gall bladder and extrabiliary tract, increased mesenteric echogenicity in the ruptured case. All presented were taken medication, surgical foreign material removal, or cholecystectomy showed complete recovery.

Glomus Tumor of the Hand

  • Lee, Won;Kwon, Soon Beom;Cho, Sang Hun;Eo, Su Rak;Kwon, Chan
    • Archives of Plastic Surgery
    • /
    • 제42권3호
    • /
    • pp.295-301
    • /
    • 2015
  • Background Glomus tumors were first described by Wood in 1812 as painful subcutaneous tubercles. It is an uncommon benign neoplasm involving the glomus body, an apparatus that involves in thermoregulation of cutaneous microvasculature. Glomus tumor constitutes 1%-5% of all hand tumors. It usually occurs at the subungual region and more commonly in aged women. Its classical clinical triad consists of pain, tenderness and temperature intolerance, especially cold sensitivity. This study reviews 15 cases of glomus tumor which were analyzed according to its anatomic location, surgical approach and histologic findings. Methods Fifteen patients with subungual glomus tumors of the hand operated on between January 2006 and March 2013, were retrospectively reviewed. Patients were evaluated preoperatively with standard physical examination including ice cube test and Love's test. Diagnostic imaging consisted of ultrasonography, computed tomography, and magnetic resonance imaging. All procedures were performed with tourniquet control under local anesthesia. Eleven patients underwent excision using the transungual approach, 3 patients using the volar approach and 1 patient using the lateral subperiosteal approach. Results Total of 15 cases were reviewed. 11 tumors were located in the nail bed, 3 in the volar pulp and 1 in the radial aspect of the finger tip. After complete excision, patients remained asymptomatic in the immediate postoperative period. In the long term follow up, patients exhibited excellent cosmetic results with no recurrence. Conclusions Accurate diagnosis should be made by physical, radiologic and pathologic examinations. Preoperative localization and complete extirpation is essential in preventing recurrence and subsequent nail deformity.

전문방사선사 제도의 개발에 관한 연구 (A Study on System Model of Clinical Specialist in Radiologic Technology)

  • 최종학;김유현;강희두;오문규;김병도;한승희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.63-76
    • /
    • 2000
  • License system of radiologic technologists has been started since 1965 in Korea. This study is to explore directions on radiotechnologists' license system classified by subspecialty. For this purpose, the authors surveyed on radiotechnologists' license system classified by subspecialty, with the subject related to radiotechnologic societies. Additionally, data on qualification and license system associated with medical and health care field were collected. The results are as follows. 1. The main body for subspecialty system for radiologic technologists should be the Korea Radiologic Technologists Association and the Association should maintain a close cooperation with radiotechnologic societies. 2. A radiologic technologist should be a basic role once they pass the license examination. In addition, they can get a special qualification by subspecialty in radiologic technology. 3. Radiotechnologists' license system classified by subspecialty will be keep priorities in order and done systematically. Execution order is as follows ; This study proposes that radiotechnologists responsible for ultrasonography, computed tomography(CT), magnetic resonance imaging(MRI) and security management be started for the first stage. For the second stage, radiotechnologists for mammography, angio-cardiography, digital imaging, maxillo-facial and dental radiography, nuclear medicine, radio-therapeutic field should be in force. 4. Professional education course(basic and intensive) and clinical training program have to be made for the eligibility of radiotechnologists' license system classified by subspecialty. 5. Eligibility system of radiotechnologists' license system classified by subspecialty(non-government or government) has to be made. Further more, inquiry commission to investigate eligibility for radiotechnologists' license system should be established.

  • PDF

Bile duct changes in rats reinfected with Clonorchis sinensis

  • Choi, Dong-Il;Hong, Sung-Tae;Li, Shun-Yu;Chung, Byung-Suk;Lim, Jae-Hoon;Lee, Soon-Hyung
    • Parasites, Hosts and Diseases
    • /
    • 제42권1호
    • /
    • pp.7-17
    • /
    • 2004
  • This study describes an evaluation of the sonographic, cholangiographic, pathological, and immunological findings, and the protective effect shown by rats reinfected with Clonorchis sinensis. Eight experimental rat groups were, namely, a normal control, a primary infection control, a reinfection I (reinfection 7 week after treatment following 3-week infection), a reinfection II (reinfection 2 week after treatment following 8-week infection), a reinfection III (exploration of the intrahepatic bile ducts 1 week after reinfection 4 week after treatment following 4-week infection), a superinfection, a secondary infection control, and an infection following immunization group. Sonographic and cholangiographic findings showed moderate or marked dilatation of the bile duct confluence in the primary infection control, reinfection II, and secondary infection control groups. Juvenile worms survived in the intrahepatic bile ducts 1 week after reinfection following treatment in the reinfection III group. It was concluded that reinfecting juvenile worms found during the first week following reinfection failed to survive or grow further. Anatomical, pathophysiological, or immunological changes may induce protection from reinfection in rats.

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

Ultrasound imaging for age-related differences of lower extremity muscle architecture

  • Kim, Min Kyu;Ko, Young Jun;Lee, Hwang Jae;Ha, Hyun Geun;Lee, Wan Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제4권1호
    • /
    • pp.38-43
    • /
    • 2015
  • Objective: To investigate and compare the size of the rectus femoris (RF), tibialis anterior (TA), and medial gastrocnemius (GMM) using ultrasound (US) imaging in young, elderly, and very elderly groups. Design: Cross sectional study. Methods: This study consisted of 25 young (age 20 years), 24 elderly (age 65-74 years), and 25 very elderly (age 75-90 years) people with no physical dysfunctions. The cross sectional area (CSAs) of the RF and muscle thickness of the TA and GMM were measured at rest and during contraction using an US system. Results: The CSA of the RF and thickness of the TA and GMM were significantly smaller in the elderly and very elderly groups than in the young group (p<0.05). There was a significant difference of the CSA of the RF at rest and during contraction between elderly and very elderly group (p<0.05). In the comparison of the TA and GMM thickness between elderly and very elderly groups, there were no significant differences except for the TA thickness during contraction. There was a significant difference in the percentage change in RF CSA among the three groups (p<0.05). Conclusions: Our results revealed loss of muscle mass in the RF, TA, and GMM in elderly and very elderly people (${\geq}65$ years old). In particular, the greatest age-related decline in muscle mass was observed for the RF. Furthermore, the CSA of the RF declined with aging in the very elderly groups (${\geq}75$ years old).

Comparison of Abdominal Muscle Thickness Using Ultrasound Imaging During Bridging Exercises With a Sling and Ball in Healthy Young Adults

  • Moon, Young;Choi, Jong-duk
    • 한국전문물리치료학회지
    • /
    • 제27권1호
    • /
    • pp.87-92
    • /
    • 2020
  • Background: Bridging exercises are used to enhance the functional stability of the lumbopelvic region in clinical settings. Although most of the studies on bridging exercises have compared the complete activation of the trunk muscles, some recent studies have examined the functional stability of the trunk and the lumbopelvic region and assessed the appropriate recruitment of the local and global muscles during different task levels. Objects: The purpose of this study was to investigate the changes in muscle thickness in the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles during a common bridging exercise on an unstable surface and to determine whether these changes differ based on the surface used. Methods: Twenty-five healthy young adults (8 males, 17 females) were recruited. The subjects were randomly assigned to either the exercise progression with a sling bridge group or the ball bridging exercise progression group, each with three stages of increasing difficulty. Each position was measured three times with an ultrasonic diagnostic imaging system, and the mean values were recorded for analysis. Results: No significant differences were observed between the TrA, IO, or EO muscle thickness ratios between the sling and ball exercise groups (p > 0.05). There were also no significant differences in the EO muscle thickness ratios between the tasks irrespective of whether the sling or ball was used. However, the TrA and IO thickness ratios in both groups were significantly greater during stages 2 and 3 compared to stage 1. Conclusion: The results suggest that the use of slings and balls during bridging exercises is effective in activating the deep abdominal muscles.

혼합모형을 이용한 반복 측정된 변수들 간의 상관분석 (Assessing Correlation between Two Variables in Repeated Measurements using Mixed Effect Models)

  • 한경화;정인경
    • 응용통계연구
    • /
    • 제28권2호
    • /
    • pp.201-210
    • /
    • 2015
  • 생명과학 또는 의학 연구에서는 반복 측정된 변수들 간의 상관 관계를 보고자 하는 경우가 발생한다. 반복 측정된 것을 고려하지 않으면 상관관계를 과소 추정하는 경향이 나타나므로 이를 고려해야 하며, 선형혼합모형의 분산-공분산 행렬을 이용하여 상관관계를 추정할 수 있다. 본 연구에서는 변수들의 반복 측정이 동시에 된 경우와 그렇지 않은 경우로 나누어 혼합모형을 이용한 상관계수의 추정방법을 소개한다. 고속 음향 복사력 임펄스 영상(acoustic radiation force impulse imaging; ARFI)으로 간과 비장에서 각각 세 번씩 전단파 속도를 반복 측정하고 복부 초음파 검사로 비장 길이를 측정한 자료에서 전단파 속도와 비장 길이 간의 상관 관계를 분석하기 위해 본 논문에서 소개한 방법들을 적용하였고 SAS의 PROC MIXED를 이용하는 방법을 제시하였다.