• Title/Summary/Keyword: Ultrasonographic evaluation

Search Result 98, Processing Time 0.026 seconds

Extraction of Muscle Areas from Ultrasonographic Images using Information of Fascia (근막 정보를 이용한 초음파 영상에서의 근육 영역 추출)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1296-1301
    • /
    • 2008
  • Ultrasonography constructs pictures of areas inside the body needs in diagnosis by bouncing high-enorgy sound waves(ultrasound) off internal tissues or organs. In constructing an ultrasonographic image, the weakness of bounding signals induces noises and detailed differences of brightness, so that having a difficulty in detecting and diagnosing with the naked eyes in the analysis of ultrasonogram. Especially, the difficulty is extended when diagnosing muscle areas by using ultrasonographic images in the musculoskeletal test. In this paper, we propose a novel image processing method that computationally extracts a muscle area from an ultrasonographic image to assist in diagnosis. An ultrasonographic image consists of areas corresponding to various tissues and internal organs. The proposed method, based on features of intensity distribution, morphology and size of each area, extracts areas of the fascia, the subcutaneous fat and other internal organs, and then extracts a muscle area enclosed by areas of the fascia. In the extraction of areas of the fascia, a series of image processing methods such as histogram stretching, multiple operation, binarization and area connection by labeling is applied. A muscle area is extracted by using features on relative position and morphology of areas for the fascia and muscle areas. The performance evaluation using real ultrasonographic images and specialists' analysis show that the proposed method is able to extract target areas being approximate to real muscle areas.

  • PDF

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

Ultrasonographic Evaluation of the External Ear Canal in Dogs (개에서 외이도의 초음파학적 평가)

  • 이해운;엄기동;성윤상;이정민;이종원;김정은;장광호;이근우;장동우
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.149-153
    • /
    • 2004
  • This study was to determine the procedure for ultrasonographic imaging of the canine external ear canal(ECC). By infusion of warm saline solution into the ear canal, a real-time B mode ultrasonographic examination of the ECC was performed in five healthy Beagle dogs and two dogs with severe otitis externa. The ultrasonography was very useful to detect the structures of the ECC and the tympanic membrane. An 11 NHz linear probe was permitted to assess an anechoic lumen of the ECC and a hyperechoic cartilage surrounding the ear canal. In two dogs with otitis externa, it could be assessed the ECC with ultrasonography without ear cleansing. A lumen of the ECC was irregular and a cerumen could be seen, but edematous inflammatory changes of the ECC could not be identified. The results suggest that ultrasonography of the ECC with an 11 NHz linear probe after infusing the saline solution into the ear canal may be an accurate, non-invasive, rapid, and widely available method for assessment of the ear canal diseases such as otitis externa, polyp, stenosis, hyperplasia, and foreign body in dogs.

Ultrasonographic Evaluation of Surgically Induced Cranial Cruciate Ligament Rupture in the Dog (개에서 전십자 인대 단열의 초음파적 평가)

  • 성윤상;엄기동;장광호
    • Journal of Veterinary Clinics
    • /
    • v.20 no.2
    • /
    • pp.229-232
    • /
    • 2003
  • Ultrasonographic examination of the stifle joint four clinically and radiographically normal adult dogs was performed before and after inducing the cranial cruciate ligament (CrCL) rupture of the bilateral stifle surgically. At Pre- or post-surgery, the hyperechoic patella ligament and the echogenic infrapatella fat interfered the visualization of the CrCL by the plain scanning method. However when the stifle joint was imaged by the scanning method injecting normal saline within the joint capsule, the hyperechogenic ligament was visualized by the separation of the infrapatella fat and the CrCL and the contrast effect of anechoic saline. When the stifle joint was imaged by the real time scanning method after the induction of the surgical rupture, fluttering of the ligament and anechoic area between the bone and the CrCL was identified due to the lack of tonicity and continuity of the ligament. Enlargement of the ligament because of its increased diameter as well as fluttering of the CrCL and the increased joint space's thickness was visualized. Consequently, confirming fluttering of the CrCL, increased ligament diameter and anechoic region between the CrCL and the bone, ultrasonographic examination is a valuable diagnostic tool as well as cranial drawer test and radiographic examination.

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

Correlations Between Ultrasonographic Findings of Sternocleidomastoid Muscle and Torticollis Overall Assessment of Congenital Muscular Torticollis in Infants (선천성 근성 사경 환아의 흉쇄유돌근 초음파 소견과 사경종합평가 사이의 상관관계)

  • Kim, Yong-Wook;Kim, Moon-Hwan;Kim, Kyoung-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.233-241
    • /
    • 2011
  • The purpose of this study was to investigate the correlation between ultrasonographic findings used to diagnose and assess of torticollis and a overall special assessment of congenital muscular torticollis in infants. Seventy-eight subjects with congenital muscular torticollis participated in this study. All the patients were divided into one of four clinical types according to the sternocleidomastoid muscle fibrosis noted on the ultrasonographic findings, and they were divided into one of three subgroups according to the degree of disability on the overall special assessment score of torticollis. For the ultrasonographic classifications of the 78 patients, 42(53.8%) made up the first type, 21 (26.9%) made up the second type, 7 (9.0%) made up the third type, and 8 (10.3%) made up the fourth type. Multivariate analysis of the results showed that the age at presentation was significantly different according to the ultrasonographic subtypes (p<0.01). There was significant correlation between the ultrasonographic findings and the torticollis overall assessment for patients with congenital muscular torticollis (${\phi}$=0.893, p<0.01). According to the results of this study, the use of the simple and objective torticollis overall assessment will be useful for the evaluation of torticollis in the future.

Subaortic Stenosis in Dogs. (개의 대동맥협착증)

  • 허진영;최지혜;최호정;이희천;이영원;박수원;엄기동;한정희;윤화영
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.523-528
    • /
    • 1999
  • Subaortic stenosis in a 2.9kg, 3-month-old pug dog and a 11 kg, 4-month-old Rott -weiler dog showing signs of dyspnea, tachypnea, anorexia, exercise intolerance and depression was diagnosed with electrocardiography, thoracic radiography and ultrasonographic evaluation. In electrocardiography, PR interval widening, R wave amplitude increase in lead II in case 2, ST segment depression and left axis deviation in case 1 and 2 were identified. In thoracic radiographs, enlarged left ventricle and atrium, caudal displacement of left crus of diaphragm and caudal part of cranial mediastinum widening were identified in ventrodorsal view. In lateral view, left ventricular enlargement, secondary dorsal deviation of trachea and post-stenotic dilation of aorta were seen. Also, edematous pulmonary changes were shown in peri-hilar area. In ultrasonographic examination, left ventricular dilatation, pericardial effusion and subaortic valvular ridge were seen with real time B-mode in right parasternal long axis view. Aortic valve regurgitation was identified in color-Doppler mode.

  • PDF

Clinical Investigation of Incidentally Found Thyroid Carcinoma in Mass Screening (집단 검진에서 발견된 갑상선 우연암종에 대한 임상적 고찰)

  • 김은서;장항석
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.2
    • /
    • pp.168-173
    • /
    • 2001
  • Background and Objectives: The introduction of highly sensitive imaging techniques has made it possible to detect many non-palpable nodules, or“incidentaloma”in the thyroid. Discovery of these lesions raises concerns about their malignancy, but the optimal strategy for managing these lesions has not been clearly established. This study was designed to evaluate the usefulness of ultrasonographic exam with new diagnostic criteria and presume the value of mass screening for thyroid cancer. Materials and Methods : Mass screening for thyroid cancer were carried out in conjunction with mass screening for breast cancer. The subjects were 630 women aged 30 years or over. Thyroid glands were examined with 10 MHz transducer ultrasonography by one radiologist. Needle aspiration biopsy were performed when suspicious of malignancy under the new diagnostic criteria. Results and Conclusion : The new ultrasonographic criteria to diagnose thyroid cancer provided useful information and ensured more accurate evaluation. 7 cases of thyroid cancer were discovered and successfully managed. It should be further demonstrated that there is sufficient value of mass screening for thyroid cancer to perform it independently despite early cancer detection.

  • PDF

Ultrasonographic and Biometric Evaluation of the Eyes of Horses and Cattle (말과 소에서 눈의 초음파측정과 생체측정의 평가)

  • ;小谷忠生
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.70-74
    • /
    • 1997
  • 말과 소의 정상 안구내의 구조와 크기를 알아보기 위하여 10마리의 말과 14두의 Holstein 안구를 적출하여 생리식염수내에서 초음파상으로 안구내의 구조를 확인하였으며 각막의 두께, 전방의 깊이, 수정체의 두께, 초자체의 깊이 및 안구축을 측정하였다. 초음파로 측정한 안구를 $-30{\circ}C$ 로 동결한 후 Diamond cutter로 절단하여 caliper로 측정하여 Student-t test로 처리하여 수치를 비교하였다. 초음파상에서 말은 암컷$(35.99{\pm}1.97)과 숫컷(35.94{\pm} 3.36)$, 좌측(36.26)과 우측$(35.67{\pm}2.65)$눈의 크기가 비슷하였으나, 소에서도 좌측$(29.06{\pm} 3.36)과 우측(28.53{\pm} 3.36)$눈의 크기가 비슷하여 통계학적 유의차는 없었다. 본 연구에서는 7.5MHz 초음파기의 B-Mode 방식을 이용하여 말과 소의 안구의 구조를 확인하고 측정하였는데 임상적으로 매우 유용하여 수의안과학에서 적용할수 있는 가치있는 진단법이다.

  • PDF