• Title/Summary/Keyword: Ultrasonographic

Search Result 536, Processing Time 0.035 seconds

Ultrasonographic Evaluation of the Thyroid Glands, Jugular Vein and Carotid Artery in Horse (말에서 갑상선, 경정맥 및 경동맥의 초음파상)

  • 김명철;김용준;변홍섭;신상태;이경광;한용만;김병선
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • Nowadays many kinds of foreign breed horse and Korean native Cheju horse are raised in Korea. Horse has complicated structure and function to maintain normal health, and to overcome severe condition during gallop at full speed. Sometimes the disease take a bad turn becuase of difficulty of correct diagnosis for horse disease. In recent times, horse farm for fattening and reproduction is gradually increasing. However, thoracic disease and abdominal disease are frequently occuring by defect in raising management. But the diagnosis of these kinds of disease is difficult by former diagnostic method. Ultrasonographic diagnostic method is a method to slove the problem. In abroad, nowadays ultrasonography has been reported for circulatory organs and abdomonal organs in horse, cattle, sheep, and dog, and the importance of ultrasonographic diagnosis is recognized in veterinary clinical medicine. In the country, ultrasonography of Korean native goat, cattle and dog was recently reported, but there was no report for the ultrasonography of horse. So, ultrasonogram for the thyroid glands, jugular vein and carotid artery was evaluated in Cheju horse and Thoroughbred horse. Thyroid gland, jugular vein and carotid artery were determined on both sides of neck. The length of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 54.8, 45.1, 46.1 and 42.2 mm, respectively. The width of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 18.1, 14.3, 14.6 and 14.2 mm, respectively. The height of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 27.3, 25.6, 26.2 and 25.5 mm, respectively. Similar ultrasonographic measurements were obtained for the left thyroid gland. The internal diameter of left jugular vein at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 10.6, 9.7, 10.5 and 9.2 mm, respectively. Similar ultrasonographic measurements were obtained for the right jugular vein. The internal diameter of right carotid artery at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 9.5, 8.8, 9.1 and 8.5 mm, respectively. Similar ultrasonographic measurements were obtained for the left carotid artery. It is concluded that the ultrasonographic values of this study provides references for the diagnosis of morphologic changes in the thyroid gland, jugular vein and carotid artery in Korean native Cheju horse and Thoroughbred horse.

  • PDF

Extraction of Muscle Areas from Ultrasonographic Images using Information of Fascia (근막 정보를 이용한 초음파 영상에서의 근육 영역 추출)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1296-1301
    • /
    • 2008
  • Ultrasonography constructs pictures of areas inside the body needs in diagnosis by bouncing high-enorgy sound waves(ultrasound) off internal tissues or organs. In constructing an ultrasonographic image, the weakness of bounding signals induces noises and detailed differences of brightness, so that having a difficulty in detecting and diagnosing with the naked eyes in the analysis of ultrasonogram. Especially, the difficulty is extended when diagnosing muscle areas by using ultrasonographic images in the musculoskeletal test. In this paper, we propose a novel image processing method that computationally extracts a muscle area from an ultrasonographic image to assist in diagnosis. An ultrasonographic image consists of areas corresponding to various tissues and internal organs. The proposed method, based on features of intensity distribution, morphology and size of each area, extracts areas of the fascia, the subcutaneous fat and other internal organs, and then extracts a muscle area enclosed by areas of the fascia. In the extraction of areas of the fascia, a series of image processing methods such as histogram stretching, multiple operation, binarization and area connection by labeling is applied. A muscle area is extracted by using features on relative position and morphology of areas for the fascia and muscle areas. The performance evaluation using real ultrasonographic images and specialists' analysis show that the proposed method is able to extract target areas being approximate to real muscle areas.

  • PDF

Serial Ultrasonographic Appearance of Postpartum Uterine Invoution in Shih-tzu Bitches (Shih-tzu 견에서 분만 후 자궁수복의 연속적 초음파상)

  • Oh Ki-seok;Kim Bang-sil;Jo Yang-tak;Ko Jin-sung;Hwang Sun-shin;Park Chul-ho;Kim Jong-taek;Park In-chul;Kim Young-hong;Son Chang-ho
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.233-238
    • /
    • 2005
  • This study was undertaken to determine the normal serial ultrasonographic appearance of the postpartum uterine involution. Postpartum changes in uterine shape, architecture, echogenicity and diameter were monitored by ultrasonography in 10 Shih-tzu bitches. Serial ultrasonographic examination was done daily during the first week, 3 days interval from 8 to 30 days, and weekly from 31 to 100 days postpartum. All 10 postpartum bitches had normal involution by gross finding, vaginal discharges, and by ultrasonographic findings, uterine shape and echogenicity. The uterine diameter in the placental sites was decreased from $23.56{\pm}1.45$ mm at 1 day to $14.08{\pm}1.55$ mm at 7 day, and in the interplacental sites was decreased from $14.64{\pm}1.28$mm at 1day to $9.61{\pm}1.46$mm at 7 day postpartum. At 65 days postpartum the uterine diameter was 5-6 mm both placental and interplacental sites, and the uterine horns were uniform hypoechic, tubular structures without enlargement. Therefore, complete involution of the uterus occured 65 days. It was concluded that normal postpartum uterine involution in Shih-tzu bitches appeared to be completed 65 days postpartum by gross findings such as vaginal discharges, and ultrasonographic findings. And ultrasonographic characteristics of the postpartum uterine involution were described. Therefore, these result suggest that ultrasonographic assessment is a reliable method for diagnosing the subinvolution of placental sites and uterine dysfunction, such as pyometra in the bitch.

Development of an Automatic Measuring Program for the Pennation Angle Using Ultrasonography Image (초음파 영상 깃각 자동 측정 프로그램 개발)

  • Kim, Jongsoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.75-83
    • /
    • 2017
  • Purpose : The parameters used in architectural analysis are muscle thickness, fascicle length, pennation angle, etc. Pennation angle is an important muscle characteristic that plays a significant role in determining a fascicle's force contribution to movement. Ultrasonography has been widely used to obtain the image for measurement of a pennation angle since it is non-invasive and real-time. However, manual assessment in ultrasonographic images is time-consuming and subjective, making it difficult for using in muscle function analysis. Thus, in this study, I proposed an automatic method to extract the pennation angle from the ultrasonographic images of gastrocnemius muscle. Method : The ultrasonographic image obtained from 10 healthy participants's gastrocnemius muscle using for developed automatic measuring program. Automatic measuring program algorithm consists with preprocessing, line detection, line classification, and angle calculation. The resulting image was then used to detect the fascicles and aponeuroses for calculating the pennation angle with the consideration of their distribution in ultrasonographic image. Result : The proposed automatic measurement program showed the stable repeatability of pennation angle calculation. Conclusion : This study demonstrated that the proposed method was able to automatically measure the pennation angle of gastrocnemius, which made it possible to easily and reliably investigate pennation angle more.

Ultrasonographic Evaluation of the Bone Beating of the Experimentally Induced Bone Defect in Dogs (개에서 실험적 골결손 치유 반응에 대한 초음파 평가)

  • Park, Jin-Hee;Seong, Yun-Sang;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.258-262
    • /
    • 2006
  • This study was performed to evaluate the usefulness of gray-scale and power Doppler ultrasonography, and to compare with radiography for detection of the repairing in experimentally induced bone defects in dogs. In 4 adult beagle dogs bilateral bone defects were created in 8 canine femurs as sized as 5 mm diameter. Mean detection time of the ultrasonographic endosteal callus formations(mean $14.25{\pm}2.31$ days) was significantly shorter than that of the radiographic opacity chanees(mean $23.50{\pm}2.27$ days) in the defected region. Mean time of the neovascularizd flow signal(mean $6.00{\pm}3.59$ days) from the power Doppler ultrasonographic examination was significantly shorter than that of gray-scale ultrasonographic findings. With these results, gray-scale ultransonography and power Doppler ultrasonography can be used for an early detection modality for bone healing.

Clinical and ultrasonographic studies for the diagnosis of ethylene glycol intoxication in dogs (개의 Ethylene glycol 중독 진단을 위한 임상 및 초음파학적 연구)

  • Byun, Hong-sub;Kim, Myung-cheol
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.629-641
    • /
    • 1998
  • This study was performed to evaluate the ultrasonographic findings of ethylene glycol intoxication. Ten healthy mongrel dogs which was administered with ethylene glycol, were evaluated in terms of clinical findings, hematological findings, blood chemistry, and ultrasonographic and histopathological findings of kidney. The results obtained through these experiment could be summarized as follows : 1. Typical clinical symptoms such as vomiting, initial apprehension, depression, thirst, dehydration, tremor, anorexia, hematuria, anuria, weakness, weight loss, flaccid paralysis, tachypnea, coma, and death, were revealed after administration of ethylene glycol. 2. Special symptom of bloody diarrhea was occurred by administration of ethylene glycol. 3. After administration of ethylene glycol, PCV was decreased continuously(p<0.01), and total leukocyte count was increased gradually, revealed the highest value at day 5 and thereafter decreased. 4. Remarkable changes of ultrasonographic findings such as high echo intensity of renal parenchyma and emergence of halo in corticomedullary junction, were revealed after administration of ethylene glycol. Early(hour 8) enlargement and late(day 3) enlargement were observed in kidney(p<0.01). Especially, late enlargement was observed concurrently with the elevation of BUN and creatinine values. 5. Calcium oxalate crystals, metabolites of ethylene glycol, were observed in histopathologic findings of kidney. Also, degeneration and necrotic exfoliation of epithelial cells were recognized in addtion to swelling of renal tubules.

  • PDF

Prenatal ultrasonographic diagnosis of cleft lip with or without cleft palate; pitfalls and considerations

  • Kim, Dong Wook;Chung, Seung-Won;Jung, Hwi-Dong;Jung, Young-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.24.1-24.5
    • /
    • 2015
  • Ultrasonographic examination is widely used for screening of abnormal findings on prenatal screening. Cleft lip with or without cleft palate of the fetus can also be screened by using ultrasonography. Presence of abnormal findings of the fetal lip or palate can be detected by the imaging professionals. However, such findings may not be familiar to oral and maxillofacial surgeons. Oral and maxillofacial surgeons can use ultrasonographic imaging of fetal cleft lip with or without cleft palate to provide information regarding treatment protocols and outcomes to the parent. Therefore, surgeons should also be able to identify the abnormal details from the images, in order to setup proper treatment planning after the birth of the fetus. We report two cases of cleft lip with or without cleft palate that the official readings of prenatal ultrasonography were inconsistent with the actual facial structure identified after birth. Also, critical and practical points in fetal ultrasonographic diagnosis are to be discussed.

Appendicitis Extraction of Abdomen Ultrasonographic Images using Facia (근막을 이용한 복부 초음파 영상에서 충수염 추출)

  • Park, Seung-Ik;Song, Doo Heon;Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2382-2387
    • /
    • 2012
  • In this paper, we propose a new method to extract and analyze appendicitis from abdomen ultrasonographic image in order to measure the thickness of appendix and change of inflammation correctly. Since the ultrasonographic image has environmental effect in nature, we standardize the image first and the process of extracting appendicitis then extracts the bottom facia which has the critical role to find appendix area. The experiment with real appendicitis patient verifies that the proposed method is more effective than current field expert's naked eye inspection.

The Analysis of Ultrasonographic Findings in Breast Carcinoma (유방암에 있어서 초음파 소견의 분석)

  • Lee, Jin-Wook;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.269-274
    • /
    • 1992
  • Authers retrospectively analyzed ultrasonographic findings of 12 cases of breast carcinomas which were proven pathologocally at Yeungnam University Hospital from March 1992 to August 1992. Classically, breast carcinomas were described as irregular and lobulated hypoechoic solid masses with inhomogenous internal echoes and frequent attenuation of the sound beam. And other additional ultrasonographic findings were echogenic rim, disruptions of superficial layer, microcalcification, skin thickening and so on. In our studies, not all of these findings of breast carcinomas were found in each case, but most of these findings were noted. However, several studies have demonstrated considerable overlap in the ultrasonographic appearance of benign lesions and carcinoma. Thus, accurate sonographic determination of the type of solid mass is not possible with current ultrasonographic imaging techniques and criteria. For more accurate diganosis of breast lesions, sonographic and other imaging techniqes are interpreted together.

  • PDF

Ultrasonographic Examination of Compression Neuropathy in the Upper Extremity (상지의 압박성 신경병증의 초음파 검사)

  • Chung, Yang-Guk;Kim, Bae-Gyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.64-72
    • /
    • 2008
  • Compression neuropathy around elbow and wrist are one of the common disturbing problems in the upper extremity. The understanding of normal nerve architectures and pathophysiologic changes in compression neuropathy is important to interpret the ultrasonographic images correctly. Compression neuropathies have characteristic ultrasonographic imaging features of flattened nerve at compression and hypoechoic swollen nerve with loss of fascicular patterns at proximal segments. Dynamic ultrasonographic imagings on motion can show dymanic subluxation of ulnar nerve and medial head of triceps muscle over the medial epicondyle in snapping triceps syndrome. Dynamic compression of median nerve also can be visualized in pronator teres syndrome by dynamic imaging studies. A quantitative measures of cross sectional area or compression ratio can be helpful to diagnose compression neuropathies, such as carpal tunnel syndrome or cubital tunnel syndrome. With the clinical features and electeophysiologic studies, the untrasonographic imagings are useful tool for evaluation of the compression neuropathies in the upper extremities.

  • PDF