• Title/Summary/Keyword: Ultrasonic therapy

Search Result 73, Processing Time 0.024 seconds

The Effects of Wound Healing of Pulsed Ultrasound in Diabetic Induced Rats (맥동성초음파가 당뇨유발백서의 창상치유에 미치는 효과)

  • Min, Soon-Gyu;Kim, Kye-Yoep;Oh, Myung-Hwa
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.1 no.1
    • /
    • pp.87-100
    • /
    • 2003
  • The present studies have been designed to evaluate the effect of acute wound healing that frequency and intensity of pulsed ultrasound application in diabetic rat. Mild diabetes mellitus was induced in rat with 45 mg/kg streptozotocin. The results were analyzed and summarized as follows: 1. The rate of wound length on ultrasonic capacity in $1.0\;W/cm^2$ $SATA_i$ group was more significantly decreased than $0.5\;W/cm^2$ $SATA_i$ group. 2. In the histological change, the $1.0\;W/cm^2$ $SATA_i$ application group was more effective than $0.5\;W/cm^2$ $SATA_i$ group, decrease of inflammatory cell was significantly in several groups. From the conclusions above, in this study application of 3 MHz pulsed ultrasound in acute wound healing, $1.0\;W/cm^2$ $SATA_i$ capacity can be an effective way of promotion wound healing than $0.5\;W/cm^2$ $SATA_i$ capacity in diabetic rat.

  • PDF

Biophysical therapy and biostimulation in unfavorable bony circumstances: adjunctive therapies for osseointegration

  • Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.195-203
    • /
    • 2012
  • Dental implants using titanium have greatly advanced through the improvement of designs and surface treatments. Nonetheless, the anatomical limits and physiological changes of the patient are still regarded as obstacles in increasing the success rate of implants further, even with the enhancement of implant products. So there have been many efforts to overcome these limits. The intrinsic potential for bone regeneration can be stimulated through adjuvant treatments with the continuous improvement of implant properties, and this can play an important role in achieving optimum osseointegration toward peripheral bone tissue and securing ultimate long-term implant stability in standard surgical procedures. For this purpose, various chemical, biological, or biophysical measures were developed such as bone grafts, materials, pharmacological agents, growth factors, and bone formation proteins. The biophysical stimulation of bone union includes non-invasive and safe methods. In the beginning, it was developed as a method to enhance the healing of fractures, but later evolved into Pulsed Electromagnetic Field, Low-Intensity Pulsed Ultrasound, and Low-Level Laser Therapy. Their beneficial effects were confirmed in many studies. This study sought to examine bone-implant union and its latest trend as well as the biophysical stimulation method to enhance the union. In particular, this study suggested the enhancement of the function of cells and tissues under a disadvantageous bone metabolism environment through such adjunctive stimulation. This study is expected to serve as a treatment guideline for implant-bone union under unfavorable circumstances caused by systemic diseases hampering bone metabolism or the host environment.

Modern acupuncture-like stimulation methods: a literature review

  • Jun, Min-Ho;Kim, Young-Min;Kim, Jaeuk U.
    • Integrative Medicine Research
    • /
    • v.4 no.4
    • /
    • pp.195-219
    • /
    • 2015
  • Acupuncture therapy has been proved to be effective for diverse diseases, symptoms, and conditions in numerous clinical trials. The growing popularity of acupuncture therapy has triggered the development of modern acupuncture-like stimulation devices (ASDs), which are equivalent or superior to manual acupuncture with respect to safety, decreased risk of infection, and facilitation of clinical trials. Here, we aim to summarize the research on modern ASDs, with a focus on featured devices undergoing active research and their effectiveness and target symptoms, along with annual publication rates. We searched the popular electronic databases Medline, PubMed, the Cochrane Library, and Web of Science, and analyzed English-language studies on humans. Thereby, a total of 728 studies were identified, of which 195 studies met our inclusion criteria. Electrical stimulators were found to be the earliest and most widely studied devices (133 articles), followed by laser (44 articles), magnetic (16 articles), and ultrasound (2 articles) stimulators. A total of 114 studies used randomized controlled trials, and 109 studies reported therapeutic benefits. The majority of the studies (32%) focused on analgesia and pain-relief effects, followed by effects on brain activity (16%). All types of the reviewed ASDs were associated with increasing annual publication trends; specifically, the annual growth in publications regarding noninvasive stimulation methods was more rapid than that regarding invasive methods. Based on this observation, we anticipate that the noninvasive or minimally invasive ASDs will become more popular in acupuncture therapy.

Effect of Visual Feedback Squat Motion on Core Muscles Thickness of Young People with Lower Back Pain

  • Jeong, HoJin;Park, ChiBock;Kim, YongNam
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.216-221
    • /
    • 2019
  • Purpose: This study examined the effect of visual feedback squat on the core muscle thickness of young adults experiencing back pain. Methods: Thirty adult men and women who experienced back pain were assigned randomly to 15 members of the visual feedback squat group (VSG) and 15 of the normal squat group (NSG) to train three times a week for a total of eight weeks. The core muscle thickness was compared prior to the test for four weeks and eight weeks after the test by dividing it into warm-up exercise, main exercise, and 10 minutes finishing exercise. Before, and four weeks and eight weeks later, the thickness of the core muscle was compared using an ultrasonic imaging system. Repeated measured ANOVA was performed to compare the groups, and a Bonferroni test was performed as a post-hoc test to assess the significance of the timing of the measurements in each group according to the periods. An independent t-test was conducted to test the significance between the groups according to the measurement points. Results: A significant change in the main effects of time and interactions of the time difference in muscle thickness of transvers abdominis were observed between the visual feedback squat and control groups according to the measurement point (p<0.05). No significant difference in the muscle thickness of both muscles was observed between the groups with the exception of the right abdominis (p>0.05). Conclusion: These findings suggest that visual feedback squat exercise is expected to have positive effects on the development of transverse abdominis in core muscles.

Heating Characteristics Evaluation of Superposed Sonication Using Glycerol Tissue Mimic Phantom (글리세롤 조직유사 팬텀을 이용한 초음파 중첩 조사에 따른 가열 특성 평가)

  • Noh, Si-Cheol;Kang, Sang-Sik;Park, Ji-Koon;Kim, Ju-Young;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.523-528
    • /
    • 2015
  • In this study, we evaluated the heating characteristics of single sonication and superposed two low-intensity ultrasonic sonication. Compare the results, the superposed sonication was showed a superior thermal effect than single sonication. And the maximum temperature was increased as 120-150%. The starting time of temperature rising has been shortened in superposed sonication. In addition, the time up to the maximum temperature has been shortened, too. In generally, as the ultrasonic intensity is higher, the more surface damage is occurred. However, in the case of superposed sonication, the same thermal effect had be confirmed without surface damage. Through the results of the study, we thought that the superposed sonication will be able to reduce the intensity of the ultrasonic treatment. And, by using the low-intensity, the more safe and more effect therapy will be possible in therapeutic ultrasound application.

A transducer array for focusing the ultrasound setting angle (초음파 집속을 위한 트랜스듀서 어레이 집속 각도 설정)

  • Lee, Sang-sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.45-48
    • /
    • 2016
  • The treatment of obesity have been developed various devices for the treatment of obesity, the ultrasound is to be made after the state changes to become easy fat decomposition by heat and vibrations to facilitate the flow of blood and lymph fatty acid released into the blood. There is such ultrasonic transducer array is used in obesity therapy focusing angle of the transducer array and the frequency may have a significant impact on the degradation of fat. In this paper, we set the frequency that reaches the shortest time to a set temperature 27kHz, 1MHz, by applying a transducer with a diameter of 5mm, 10mm, 16mm for the frequency of 3MHz, obtain the wavelength and near the stomach in order to set the frequency of the transducer array, which was set to the focusing angle of the transducer with three contact surfaces. As a result, the time to reach the set temperature was short days when 3MHz frequency, the focusing angle is titrated is $40^{\circ}$.

Comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit for the removal of separated endodontic instruments

  • Pruthi, Preeti Jain;Nawal, Ruchika Roongta;Talwar, Sangeeta;Verma, Mahesh
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.14.1-14.7
    • /
    • 2020
  • Objective: The aim of this study was to perform a comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit (TFRK) for the removal of broken endodontic instruments. Materials and Methods: A total of 80 extracted human first mandibular molars with moderate root canal curvature were selected. Following access cavity preparation canal patency was established with a size 10/15 K-file in the mesiobuccal canals of all teeth. The teeth were divided into 2 groups of 40 teeth each: the P group (ProUltra tips) and the T group (TFRK). Each group was further subdivided into 2 smaller groups of 20 teeth each according to whether ProTaper F1 rotary instruments were fractured in either the coronal third (C constituting the PC and TC groups) or the middle third (M constituting the PM and TM groups). Instrument retrieval was performed using either ProUltra tips or the TFRK. Results: The overall success rate at removing the separated instrument was 90% in group P and 95% in group T (p > 0.05) The mean time for instrument removal was higher with the ultrasonic tips than with the TFRK (p > 0.05). Conclusion: Both systems are acceptable clinical tools for instrument retrieval but the loop device in the TFRK requires slightly more dexterity than is needed for the ProUltra tips.

Effects of resolution of inflammation for low-power $CO_2$ laser treatment on gingivitis patients (치은염 환자에서 저출력 이산화탄소 레이저의 염증완화 효과에 관한 연구)

  • Song, Hyun-Jong;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.657-668
    • /
    • 2008
  • Purpose: In this study, we compared low-power $CO_2$ laser treatment to ultrasonic scaling, which is generally approved as a power-driven mechanical instrumentation, and evaluated both of these treatments regarding their clinical effectiveness and change in the volume of in GCF. Material and methods: 20 patients who had gingivitis were selected. all of patients has no systemic problems. Randomly selected, one quadrant received ultrasonic scaling only, another quadrant received ultrasonic scaling and $CO_2$ laser irradiation, the other quadrant received $CO_2$ laser irradiation only. Clinical parameters measured at baseline, 1 weeks, 2weeks, 4weeks and 8weeks. Result: Pocket probing depth and clinical attachment level were not changed during study period. Gingival index of all group were improved after treatment. At 1 weeks after treatment, Gingival index of ultrasonic scaling group was only significantly different compared to control group. At 2 weeks after treatment, gingival index of all experimental group were significantly different compared to control group. At 4 and 8 weeks after treatment, gingival index of all group were increased, but experimental group were lower than control group. Sulcus bleeding index was similar to the results of gingival index. At 1 weeks after treatment, all experimental group were significantly different compared to control group and it maintained during study. At 2 weeks after treatment, sulcus bleeding index of all group were lowest during study. Gingival crevicular fluid were measured with $Periotron^{(R)}$ 8000($Oraflow^{(R)}$, Inc. USA). At baseline, all group were showed moderately severe condition. At 1 week after treatment, laser treatment only group was reduced quantity of gingival crevicular fluid mostly, and all group were reduced quantity of gingival crevicular fluid. At 2 weeks after treatment, all group were health state. At 4 and 8 weeks after treatment, all group were showed recurrent of inflammation, and control group was the most significantly increased. Conclusion: This study showed that the effects of $CO_2$ laser treatment were similar to conventional ultrasonic scaling and this result remained longer than plaque control only. These results suggest possibility of $CO_2$ laser treatment for altered periodontal therapy.

Comparison of Abdominal Muscle Thickness Using Ultrasound Imaging During Bridging Exercises With a Sling and Ball in Healthy Young Adults

  • Moon, Young;Choi, Jong-duk
    • Physical Therapy Korea
    • /
    • v.27 no.1
    • /
    • pp.87-92
    • /
    • 2020
  • Background: Bridging exercises are used to enhance the functional stability of the lumbopelvic region in clinical settings. Although most of the studies on bridging exercises have compared the complete activation of the trunk muscles, some recent studies have examined the functional stability of the trunk and the lumbopelvic region and assessed the appropriate recruitment of the local and global muscles during different task levels. Objects: The purpose of this study was to investigate the changes in muscle thickness in the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles during a common bridging exercise on an unstable surface and to determine whether these changes differ based on the surface used. Methods: Twenty-five healthy young adults (8 males, 17 females) were recruited. The subjects were randomly assigned to either the exercise progression with a sling bridge group or the ball bridging exercise progression group, each with three stages of increasing difficulty. Each position was measured three times with an ultrasonic diagnostic imaging system, and the mean values were recorded for analysis. Results: No significant differences were observed between the TrA, IO, or EO muscle thickness ratios between the sling and ball exercise groups (p > 0.05). There were also no significant differences in the EO muscle thickness ratios between the tasks irrespective of whether the sling or ball was used. However, the TrA and IO thickness ratios in both groups were significantly greater during stages 2 and 3 compared to stage 1. Conclusion: The results suggest that the use of slings and balls during bridging exercises is effective in activating the deep abdominal muscles.

Comparison of the Ratio of Thicknesses of the Rhomboid Major and Middle Trapezius Muscles While Performing Scapular Retraction Exercises (어깨뼈 뒤 당김 운동 방법에 따른 큰마름근과 중간등세모근의 근두께비의 비교)

  • Park, Heon-mi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • Background: Shoulder impingement syndrome, a major cause of shoulder pain, involves weakness of the scapular retractor muscles. The major scapular retractor muscles are the middle trapezius and rhomboid major muscles; however, the latter is excluded in most studies. Objects: We aimed to measure the thickness of the middle trapezius and rhomboid major muscles using an ultrasonic diagnostic imaging system while performing four different shoulder retraction exercises and comparing the thicknesses and ratio of the thicknesses of these muscles. Methods: The thickness of the middle trapezius and rhomboid major muscles was measured in 24 healthy adults using ultrasound. Muscle thickness was measured three times in the Reference posture and four times while performing four different exercises that involved scapular retraction. The averages and standard deviations of the measured muscle thicknesses were obtained and compared. The ratio of muscle thickness and rate of changes in muscle thickness between the reference posture and the four exercises were compared. Results: For both, male (n = 10) and female (n = 14), there was a significant difference in the thickness of the middle trapezius muscle between the reference posture and the four exercises (p < 0.05) and in the thickness of the middle trapezius and rhomboid major muscles between male and female (p < 0.05); however, there was no significant difference in the ratio of the thicknesses of these muscles. Although a significant difference in the rate of change in muscle thickness during the four exercises was noted, there was no significant difference in the ratio of change in muscle thickness. Conclusion: This study demonstrates the ratio of the thicknesses of the middle trapezius and rhomboid major muscles and the rate of change in their thickness during exercises involving scapular retraction in healthy people in their 20s-30s.