• 제목/요약/키워드: Ultrasonic source

검색결과 168건 처리시간 0.03초

유중 방전에 의한 초음파 측정용 광섬유 센서 특성 및 측정 데이터 분석 (Characteristics and Signal Analysis of Fiber-optic Sensor for Detecting Ultrasonic Waves Generated by Discharge in Insulation Oil)

  • 이상훈;송현직;이광식;김달우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.481-486
    • /
    • 2003
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

수중에서 2개의 광섬유센서를 이용한 초음파 음원의 위치 검출에 관한 연구 (A Study on Ultrasonic Location in Underwater Using the Two Optical Fiber Sensors)

  • 권태호;신대용;이준호;이종길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.62-66
    • /
    • 2002
  • The preliminary results on the application of optical fiber sensor(OFS) for locations of ultrasonic signals in underwater are presented and analyzed. The OFS utilizing the principle of Sagnac interferometry was designed and the hollowed cylindrical mandrel wound by single mode optical fiber was used as sensing component. The ultrasonic signal source was simulated by the PZT actuator operated with function generator. It has been shown that the OFS could detect the signals less affected by ultrasonic path comparing to conventional acousto-electric sensor and accurate location of ultrasonic signal could be carried out using two OFSs.

  • PDF

Trimethyl-indium 소스 고갈에 따른 InGaAsP 에피층의 특성 변화 (Effect of trimethyl-indium source depletion on InGaAsP epilayer grown by MOCVD)

  • 김현수;오대곤;편광의;최인훈
    • 한국진공학회지
    • /
    • 제9권4호
    • /
    • pp.400-405
    • /
    • 2000
  • 유기금속 소스의 농도를 연속적으로 in-situ 측정이 가능한 EPISON ultrasonic monitor를 이용하여 TMIn(trimethly-indium)의 소스 고갈이 InGaAs, InGaAsP bulk 에피층과 1.55 $mu extrm{m}$ InGaAs/InGaAsP SMQW (strained multi-quantum well)에 미치는 영향을 조사하였다. TMIn 소스는 사용량이 80%에서 급격하게 소스 고갈 현상을 보였다. TMIn 소스는 사용량이 80%에서 급격하게 소스 고갈 현상을 보였다. TMIn 소스 고갈에 의한 에피층의 특성 변화를 조사한 결과, bulk 에피층의 경우에는 소스가 고갈 되기 전에 성장한 에피층과 비교하여 DCXRD(double crystal X-ray diffractometry) spectrum에서 피크 분리가 약 300 arcsec정도 Ga-rich 방향으로 이동하였으며 relative FWHM은 약 2배 가량 증가하는 것을 보였다. SMQW 구조에서는 bulk 에피층과는 달리, PL 중심파장에서도 약 40 nm 정도 단파장쪽으로 이동하였으며, 피크 분리는 약 300 arcsec정도 Ga-rich 방향으로 이동하였다. 하지만, EPISON의 closed loop 기능을 사용할 경우에는 TMIn 소스 사용량이 95%에서도 피크 분리가 $\pm$100 arcsec이내의 재현성 있는 에피층 성장이 가능하다는 것을 알 수 있었다.

  • PDF

변압기 부분방전과 노이즈에 의한 초음파 신호 분석 (Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer)

  • 권동진;정길조;진상범;곽희로
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

초음파 검사실의 조도 환경에 관한 연구 (A Study on the Illumination Environment of Ultrasound Examination Room)

  • 임인철;이효영;안현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.213-219
    • /
    • 2017
  • 본 연구의 목적은 초음파 검사실의 검사환경 설정에 있어 실증적인 기초자료를 제공하는 것에 그 목적을 두고 새로운 초음파 검사실의 검사환경을 설계함에 있어 검사실의 적정조도를 설정하는데 기초자료로 제공하고자 한다. 방법으로는 부산에 소재하고 있는 종합병원 6군데 48곳의 초음파 검사실을 대상으로 조도와 관련된 초음파실 환경을 조사하고 초음파 검사대상자에게 초음파 검사실 환경에 대하여 설문조사를 실시하였다. 결과로는 초음파 검사실 차폐체의 종류에서는 성별, 연령별, 검사부위에 따른 분석에서 모두 Door+Curtain에서, 광원의 종류에서는 LED, 광원조절기가 필요하다에서 점수가 높게 나타났다. 초음파 검사실 환경조사에서는 초음파 검사실 조도 밝기는 평균 10 Lux로서 WHO와 CEC에서 권고하는 조도 밝기범위에 포함되고 있었으며 초음파 검사 대기실 조도 밝기(초음파 검사 대기실, 복도)는 평균 300~800 Lux를 나타내어 KSA 3011에서 권고하는 병원의 조도환경인 300 Lux이상을 만족하였다. 결론적으로 초음파 검사 대상자의 일반적인 배경과 초음파 검사실 관련 환경 요인을 분석한 결과를 토대로 향후 초음파 검사실 환경을 개선하거나 새로운 검사실을 설계함에 있어 기초자료로 제공하고자 한다.

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.

유중방전 초음파 신호의 광학적 측정 및 wavelet 분석 (The optical measurement and wavelet analysis about ultrasonic signals by discharge in oil)

  • 이상훈;이현철;지승욱;김충년;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.298-303
    • /
    • 2004
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based rut the needle-plane electrode system in oil and applied AC high voltage Ultrasonic waves were detected and showed signal- analysis results with wavelet transform.

  • PDF

유도초음파의 반사법과 투과법 비교를 통한 록볼트 건전도 평가 (Rock bolt integrity evaluation using reflected and transmitted guided ultrasonic waves)

  • 이종섭;유정동;한신인;배명호;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.42-50
    • /
    • 2008
  • To evaluate rock bolt integrity, destructive test such as pull-out test has been commonly carried out. This method is known as time consuming, expensive, and inaccurate procedure. To improve destructive method, non-destructive techniques using transmitted guided ultrasonic waves were suggested. Note for the transmission method, the source for the generation of ultrasonic waves should be installed during the rock bolt construction. The purpose of this study is to investigate the reflection method using reflected guided ultrasonic waves to evaluate the integrity of the rock bolt grouted, and to compare the results evaluated by the reflection and transmission methods. The guided waves are generated by PZT element and received by AE sensor. The measured signals are analyzed by the wavelet transform. The results show that the energy velocities of guided ultrasonic waves increase with the defect ratio in both transmission and reflection method. The reflection method produces the lower velocity in all defect ratio. This research demonstrates that the reflection method may be suitable and easer method for the field tests.

  • PDF

FEM을 이용한 초음파 용착부의 온도분포 해석 (Temperature Distribution Analysis of Welding Parts in Ultrasonic Welding by Using FEM)

  • 강은지;민경탁
    • 한국생산제조학회지
    • /
    • 제25권2호
    • /
    • pp.105-111
    • /
    • 2016
  • Ultrasonic metal welding, unlike the conventional welding techniques, does not require an external heat source, welding rod, or filler metal. Therefore, ultrasonic metal welding is not only economical but also environment-friendly, and hence, it has been receiving much attention. In ultrasonic welding, heat is generated because of the plastic deformation and the friction between both surfaces of the welded materials. It is important to identify the heat-affected zone by measuring the temperature generated at the weld. In this study, the effects of the welding pressure, welding time, and vibration amplitude on the temperature distribution in the weld were evaluated by performing a transient thermal analysis of the heat generated during ultrasonic metal welding. The experimental results indicated that the temperature of the weld tends to increase with the welding time and vibration amplitude. However, an increase in the pressure does not affect the temperature of the weld largely.

압전 횡효과를 이용한 무지향성 주파수가변 초음파트랜스듀서 (Frequency Controllable Wide-Beam Ultrasonic Transducer with Transverse Mode)

  • 김정순;김무준;하강렬;강갑중
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.417-423
    • /
    • 2004
  • In order to obtain wide-beam characteristics and variable resonant frequency of a ultrasonic transducer for the array source, an electrode of transverse mode piezoelectric vibrator is divided, and an electronic inductance is connected to the divided electrodes. The electronic inductance is made by GIC (General Impedance Converter) circuit. Because the GIC circuit is made of OP-Amps and other passive elements, the value of the inductance can be selected easily. As the results, the electronic inductance is variable in the range from 0.2 mH to 1.2 mH. Using the inductance, the resonance frequency of the transducer can be changed in the range from 73 kHz to 86 kHz. In the directivity of the transducer, it is confirmed that the beam width of the transducer is wider than $80^{\circ}$ at -3 dB in water.