• Title/Summary/Keyword: Ultrasonic probe

Search Result 162, Processing Time 0.027 seconds

Comparison of Egg Testing Devices for Internal Egg Quality Measurements (계란 할란검사장비의 성능 비교)

  • Kim, Dong Jun;Jeon, Seung Yob;Kim, Hee Won;Won, Jea Sun;Lee, Jae Cheong;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.43 no.4
    • /
    • pp.229-233
    • /
    • 2016
  • This study was conducted to compare three commercially available egg testing devices for measuring egg quality. The devices used were a Laser-type (automatic), a Ultrasonic-type (automatic), and a Probe-type (manual). Fresh eggs weighing 60~68 grams were obtained from a commercial hen farm. Three trials were conducted. In Trial 1, a total of 50 eggs were successively analyzed by the three egg testing devices. In Trial 2, fresh eggs were successively analyzed by a combination of two egg testing devices. In Trial 3, a total of 600 eggs (weighing 60~68 grams) laid by same flock were selected, further divided into three sub-groups with a total of 200 eggs, and analyzed by an egg testing device. In Trials 1 and 2, no apparent difference was observed in egg weight between egg testing devices. However, albumin height was scored highest in the Ultrasonic-type egg tester followed by the Probe-type and Laser-type (Trials 1 and 2). Consequently, the Haugh unit was similarly altered. Yolk color was highest in the Laser-type egg tester followed by the Ultrasonic-type and Probe-type (Trials 1 and 2). When fresh eggs laid by a single flock were independently analyzed by three devices, egg weight did not differ, but albumin height and Haugh unit were higher (p<0.05) in the Ultrasonic-type egg tester than in the Probe-type or Laser-type testers. However, Laser-type testers produced higher (p<0.05) yolk color values than the Ultrasonic-type or Probe-type egg testers. In conclusion, the commercially available egg testing devices exhibited performance differences in measuring egg qualities, which warrants further consideration as to whether the magnitude of bias and precision between the devices could be acceptable in the egg grading system, especially when assessing eggs stored for certain durations.

Development of 1-3 Piezocomposite Ultrasonic Transducers by means of the Finite Element Method (유한요소 해석법을 이용한 1-3형 압전복합체 초음파 트랜스듀서의 개발)

  • 이수성;김동현;한진호;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.274-281
    • /
    • 2004
  • In this study. a 1-3 piezo-composite single element ultrasonic transducer was designed with a commercial finite element analysis (FEA) code. PZf1ex and developed based on this design. Design with FEA could be performed overcoming many constraints of the typical theoretical method, and also was very practical. Validity of the design with the FEA was illustrated through experimental characterization of fabricated 1-3 piezo-composites and ultrasonic transducers, Through comparison with the result of the theoretical method. we confirmed the superiority of the design method using FEA.

Quantitative Evaluation of Flaw by Ultrasonic Spectroscopy (초음파 주파수 분석법에 의한 결함의 정량적 평가에 관한 연구)

  • 한응교;김성규;박준서;이범성;박익근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.1004-1010
    • /
    • 1992
  • In recent years, along with the development of ultrasonic probe with wide frequency range, the digitization of measuring instrument, and the development of operating process technics, it is possible to analyze ultrasonic pulse in frequency range. In this paper, applying to flaw model the ultrasonic spectroscopy method that can analyze ultrassonic pulse in frequency range, we examine the possibility of quantification of flaw and apply its result to the void and seperation in LSI package. Consequently, by using the change in frequency distribution and central frequency of sltrasonic pulse detected from flaw, the estimation of shape, size, and depth of flaw is possible. The change in central frequency is changed minutely by the sample materals and position of flaw, but changed mainly by the shape and size of flaw. And we can quantify the shape and size of flaw in LSI pakcage using the experimental result through flaw model.

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

Estimation of Setting Time and Early-age Strength of Concrete Using the Ultrasonic Pulse Velocity (초음파 속도를 이용한 콘크리트의 응결 및 초기 강도 추정)

  • Lee, Hoi-Keun;Lee, Kwang-Myong;Kim, Young-Hwan;Yim, Hyun-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.292-303
    • /
    • 2002
  • This paper presents experimental results for early-age properties of concrete such as the setting time and strength, evaluated via the ultrasonic pulse velocity (UPV). Developing and using an automatically-recording monitoring system, the UPV's of mortar and concrete with various water to binder ratios (W/B) were measured during the first 24 hours. In addition, probe penetration and compression tests were conducted to measure the setting time and compressive strength, respectively. It was observed that the UPV's of mortar with high W/B remained constant during the first 6.5 hours and then abruptly began to increase at constant rates. On the other hand, the UPV of mortar with low W/B increased relatively slowly and gradually due to the setting retardation caused by the use of high range water reducing agent (HRWR). It was found that setting of concrete occurs when the UPV reaches a certain value. Moreover, it was concluded that the estimation formulas should incorporate the effects of W/B to more accurately estimate the early-age strength of concrete from the UPV.

Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique (Full Matrix Capture 기법을 통한 초음파신호 영상화 향상 연구)

  • Lee, Tae-Hun;Yoon, Byung-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.299-306
    • /
    • 2015
  • A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased array transducer element through all the other elements and captures the complete dataset from every possible transmit-receive combination. This FMC data can be used to create the ultrasonic image in post processing. It is possible to produce not only images equivalent to conventional phased array image but also total focusing method (TFM) images with improved resolution and sharpness, which is virtually focused at any point in a region of interest. In this paper, the system that can perform FMC by using a conventional phased array instrument is developed, and a study was conducted on the imaging algorithms to reconstruct sector B-scan and TFM images from FMC dataset.

The Stereomicroscope and SPM Study on the Marginal Change of Porcelain Crown in Various Repeated Instrumentations for Periodontal Therapy (치주처치를 위한 기구의 반복 사용시 도재관 변연부 변화에 관한 입체 및 주사탐침현미경적 연구)

  • Lee, Si-Cheol;Chung, Chin-Hyung;Yim, Seong-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.455-472
    • /
    • 2000
  • Instrumentation for periodontal therapy may induce marginal damage which increases plaque accumulation and result in periodontal disease. But there have not been many reports of instrumentations on the artificial crown so far. Therefore this study is conducted to evaluate the effects of various repeated instrumentations on the porcelain crown marginal portion. Of the 10 extracted periodontally diseased maxillary first premolars, were 12 proximal surface used in this study. The finishing line of the preparation was placed on the root surface below CEJ and then the crown was cast and cemented in usual manner. Every 4 surfaces of the 3 instruments-curet, ultrasonic scaler, and ultrasonic curet- is used. and four samples used in each instruments. The relevant procedures and measurements were repeated 3 times in each surfaces. Marginal gap is measured by the microscope and surface roughness, Scannig Probe Microscope. Measurements are made at 5 points in each surfaces, making 20 points in each instrument. The results evaluated statistically were as follows 1. As instrumentation was repeated, both marginal gap and roughness were increased in all group 2. In the hand curet, marginal gap was increased every instrumentation and roughness was increased after second. 3. In the ultrasonic scaler, both marginal gap and roughness were increased every instrumentation. 4. In the ultrasonic curet, marginal gap was increased after third instrumentation and roughness was increased after second. 5. Marginal gap and roughness used by the ultrasonic curet were lower than the others and no difference was seen between the hand curet and ultrasonic scaler From the results of this study, the ultrasonic curet was useful in some aspect, but careful instrumentation was needed. Furthermore it was important to minimize the instrumentation through complete periodontal therapy before setting and adequate plaque control.

  • PDF

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

A Study on the Size Evaluation of Disc and Band Type Flaw by Ultrasonic Tandem Testing (초음파(超音波)TANDEM사각법(斜角法)에 의한 원형(圓形) 및 띠형결함(形缺陷)의 크기 평가(評價)에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Kim, J.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.12-21
    • /
    • 1986
  • Generally, butt welds with plate thickness $30{\sim}40mm$ are welded with groove angle $40^{\circ},\;60^{\circ},\;70^{\circ}$, etc. In the detection of internal weld defects, oblique testing with single probe has been mainly used. But, recently, in acccordance with enlargement of welded structure, thick plate with 100-200mm are frequently required. Thus I-groove welding method was lately developed and often used. In this case, most frequently generated defects are the lack of weld penetration and incomplete fusion between base metal and welding material. If we would detect by oblique testing with single probe, detecting flaw is occassionally impossible or very underestimated. In this study, the limit for applying tandem method was studied in dise and band type flaws. The estimation of flaw size could be within 10% error compared to real flaws.

  • PDF

Fabrication of Nanoscale Structures using SPL and Soft Lithography (SPL과 소프트 리소그래피를 이용한 나노 구조물 형성 연구)

  • Ryu Jin-Hwa;Kim Chang-Seok;Jeong Myung-Yung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.138-145
    • /
    • 2006
  • A nanopatterning technique was proposed and demonstrated for low cost and mass productive process using the scanning probe lithography (SPL) and soft lithography. The nanometer scale structure is fabricated by the localized generation of oxide patterning on the H-passivated (100) silicon wafer, and soft lithography was performed to replicate of nanometer scale structures. Both height and width of the silicon oxidation is linear with the applied voltagein SPL, but the growth of width is more sensitive than that of height. The structure below 100 nm was fabricated using HF treatment. To overcome the structure height limitation, aqueous KOH orientation-dependent etching was performed on the H-passivated (100) silicon wafer. Soft lithography is also performed for the master replication process. Elastomeric stamp is fabricated by the replica molding technique with ultrasonic vibration. We showed that the elastomeric stamp with the depth of 60 nm and the width of 428 nm was acquired using the original master by SPL process.