• Title/Summary/Keyword: Ultrasonic method

Search Result 2,080, Processing Time 0.028 seconds

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.

An Study on flow Discharge Calculation using Surface Velocity (비접촉식 유속계의 표면유속을 이용한 유량산정방법에 관한 연구)

  • Roh, Youngsin;Lee, Sin Jae;Kim, Dae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.230-230
    • /
    • 2020
  • 하천 유량측정을 위한 표면유속계는 비접촉식 방식이기 때문에 현장에서의 측정이 간편하고, 비교적 안전하기 때문에 홍수시 유량측정에 널리 이용되고 있다. 비접촉식 유속계가 가지고 있는 이러한 장점으로 전자파표면유속계의 활용이 점차 증가하고 있으며, 영상유속계와 같은 비접촉 측정방식의 활용방안 마련에 대한 연구개발 등이 꾸준히 진행되어 왔다. 최근에는 고정식으로 상시 운영이 가능한 표면유속계 등이 출시되어 소규모 하천이나 수로에서의 상시 유량측정에 활용되고 있다. 다만, 이러한 비접촉식 유속계는 표면의 유속을 측정하기 때문에 유량산정을 위해서는 평균유속으로의 환산이 필요하지만, 현재까지는 평균유속 환산계수를 사용하여 표면유속을 평균유속으로 환산하는 방법이 유일하게 활용되고 있다. 하지만, 실제 하천에서는 단면 및 하도형태, 하상조건, 수리특성 및 유속분포 등의 다양한 조건에 따라 환산계수가 결정되기 때문에 이를 단순히 일률적으로 적용하는 것은 곤란하며, 이로 인해 과거 오랫동안 표면유속을 평균유속으로 환산하기 위한 다양한 연구가 진행되었지만, 실제 다양한 조건의 하천에 적용할 수 있는 표준화된 방법은 아직까지 제시되지 못하고 있다. 현재까지, 고정식으로 설치된 유속계로부터 측정된 유속을 평균유속으로 환산하는 방법으로는 국내외적으로 지표유속법(Index Velocity Method)과 유속분포법(Velocity Profile Method)이 대표적이며, H-ADCP (Horizontal-Acoustic Doppler Velocity Profiler) 또는 UVM(Ultrasonic Velocity Meter) 등과 같은 초음파유속계를 활용한 자동유량측정시설의 유량산정방법으로 활용되고 있다. 이러한 방법들은 고정된 유속계의 측정유속을 지표유속(Vi)으로 하여 다양한 범위의 실측된 평균유속과의 관계를 개발하여 활용하거나, 지표유속을 매개로 개수로 단면의 이론적인 유속분포를 추정하여 평균유속을 산정한다. 이러한 지표유속을 활용하는 방법들에서 공통적으로 중요한 것은 하천단면의 최대유속(Vmax)이 가장 좋은 지표유속이라는 것이다. 따라서 국제기준에서는 지표유속을 측정하는 유속계의 가장 바람직한 위치로 유심부(core flow)를 권장하고 있다. 하지만, 접촉식 유속계의 경우 유심부 설치가 매우 어렵고 많은 비용이 들기 때문에, 비접촉식 유속계를 활용하여 하천단면의 최대유속을 측정할 수 있다면, 가장 효율적인 고정식 측정방법이 될 수 있을 것이다. 따라서, 본 연구에서는 비접촉식 표면유속계의 고정식 유량측정 활용성 및 적용성을 검토할 목적으로 표면유속에 대한 유량산정방법을 검토하였다. 이를 위해 24GHz의 주파수를 갖는 레이다표면유속계인 Sensoflow를 낙동강 수계 길안천에 위치한 안동시(대사3교)에 고정설치하여 표면유속을 지표유속으로 수집하였다. 다양한 유량규모에서 측정한 실측 표면유속과 수집된 표면유속을 지표유속으로 활용하여 지표유속관계를 개발하였으며, 산정된 유량을 기존 수위-유량관계곡선식의 환산유량과 비교하여 표면유속의 지표유속 활용성을 검토하였다.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Performance Analysis of Implementation on IoT based Smart Wearable Mine Detection Device

  • Kim, Chi-Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.51-57
    • /
    • 2019
  • In this paper, we analyzed the performance of IoT based smart wearable mine detection device. There are various mine detection methods currently used by the military. Still, in the general field, mine detection is performed by visual detection, probe detection, detector detection, and other detection methods. The detection method by the detector is using a GPR sensor on the detector, which is possible to detect metals, but it is difficult to identify non-metals. It is hard to distinguish whether the area where the detection was performed or not. Also, there is a problem that a lot of human resources and time are wasted, and if the user does not move the sensor at a constant speed or moves too fast, it is difficult to detect landmines accurately. Therefore, we studied the smart wearable mine detection device composed of human body antenna, main microprocessor, smart glasses, body-mounted LCD monitor, wireless data transmission, belt type power supply, black box camera, which is to improve the problem of the error of mine detection using unidirectional ultrasonic sensing signal. Based on the results of this study, we will conduct an experiment to confirm the possibility of detecting underground mines based on the Internet of Things (IoT). This paper consists of an introduction, experimental environment composition, simulation analysis, and conclusion. Introduction introduces the research contents such as mines, mine detectors, and research progress. It consists of large anti-personnel mine, M16A1 fragmented anti-mine, M15 and M19 antitank mines, plastic bottles similar to mines and aluminum cans. Simulation analysis is conducted by using MATLAB to analyze the mine detection device implementation performance, generating and transmitting IoT signals, and analyzing each received signal to verify the detection performance of landmines. Then we will measure the performance through the simulation of IoT-based mine detection algorithm so that we will prove the possibility of IoT-based detection landmine.

Anti-inflammatory Efficacy and Liver Protective Activity of Pine Pollen according to Probe Sonicator Ultrasonic Disintegration Extraction Method (송화분의 초음파 파쇄 추출 방법에 따른 항염증 효능 및 간 보호 활성)

  • Kim, Ok Ju;Woo, Young Min;Jo, Eun Sol;Jo, Min Young;Li, Chun-Ri;Lee, Young-Ho;Ahn, Mee Young;Lee, Sang-Hyeon;Ha, Jong Myung;Kim, Andre
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.569-579
    • /
    • 2019
  • In this study, the effect anti-oxidant, anti-inflammatory, and liver protective activity was investigated via quick ultrasonic disintegration of pine pollen using a probe sonicator (PS) followed by the extraction with water, 70% ethanol, and 100% ethanol. The anti-inflammatory effect was studied by measuring the production of nitric oxide (NO) and cytokine in RAW264.7 cells induced with lipopolysaccharides (LPS). The cell toxicity was also checked with an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and the experiment was conducted using non-toxic $100{\mu}g/mL$. The NO inhibition rate was highest in the 70% ethanol PS group at $85.99{\pm}0.12%$. Also an excellent efficiency was obtained from the results of interlukin-1 beta ($IL-1{\beta}$) and tumor necrosis factor alpha ($TNF-{\alpha}$), which is related to inflammation-related cytokine, with the respective inhibition rates of 63 and 22%. To examine liver protective activity, HepG2 cells were treated with Taclin, and the generation of glutamic oxaloacetic transaminase (GOT) and lactate dehydrogenase (LDH) was measured in the culture solution. From GOT and LDH generation results, the inhibition rates in the 70% ethanol PS group were 28% and 13%, respectively, which was higher compared to that of using negative control group. Our results suggest that pine pollen extracted in 70% ethanol using PS may be used to develop food products that have anti-aging, anti-inflammatory, and liver protective effects.

Evaluation of Physical Properties and Material Characterization for Structural Frame at the Stained Glass Windows to Gongju Jeil Church of the Registered Cultural Heritage in Korea (국가등록문화재 공주제일교회 스테인드글라스 구조재의 재질특성과 물성 평가)

  • Bo Young Park;Hye Ri Yang;Chan Hee Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.1
    • /
    • pp.103-114
    • /
    • 2023
  • The Christian Museum of Gongju Jeil Church was first built in 1931 and was largely damaged during the Korean War, but the walls and chimneys have been preserved. This building has a high architectural values in that the chapel was reconstructed in 1956, and maintains its original form through repair of damaged parts rather than new construction. The stained glass windows were as installed in 1979 and has a great significance in the Dalle de Verre method using lump glass. However, some of the stained glass damaged partially, such as various cracks and splits, and vertical and horizontal cracks in the joint fillers of supporting the colored glass. As the structural materials of the stained glass window, an iron frame and cement mortar filled with it were used, and corrosion of iron, cracking of mortar and granular decomposition appear partially due to weathering. In the joint fillers, the content of Ca and S is very high, indicating that gypsum were used as admixtures, and the gypsums grow in a rhombohedral and forms a bundle, which is investigated to have undergone recrystallization. As a result of modeling the ultrasonic velocity at the joint fillers, the left and right windows at the entrance show relatively weak in the range of 800 to 1,600m/s, and the lower right corner of the altar window and the upper left corner of the center window were also 1,000 to 1,800m/s, showing relatively low physical properties. And gypsums produced during the neutralization of lime mortar were detected in the joint fillers and contaminants on the surface. Such salts may cause damage to the joint material due to freezing and thawing, so appropriate preventive conservation is required. Also, since various damage types are complexly appearing in stained glass window and joint filler, customized conservation treatment should be reviewed through clinical tests.

THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES (임플란트 표면에 따른 인공치면세균막 형성에 관한 연구)

  • Kim, Jin-Woo;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

Dependencies of Group Velocity and Attenuation Coefficient on Structural Properties in Copper and Nickel Foams with an Open-Celled Structure as Trabecular-Bone-Mimicking Phantoms (해면질골 팬텀으로서 개포된 구조를 갖는 구리폼 및 니켈폼에서 구조적 특성에 대한 군속도 및 감쇠계수의 의존성)

  • Kim, Seong-Il;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.158-166
    • /
    • 2011
  • In the present study, copper and nickel foams with an open-celled structure as trabecular-bone-mimicking phantoms were used to investigate the dependencies of group velocity and attenuation coefficient on structural properties such as trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) in trabecular bone. The group velocity and attenuation coefficient of the copper and nickel foams were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. The separation of the Biot's fast and slow waves was consistently observed in the ultrasonic signals transmitted through the copper and nickel foams. The group velocities of the copper and nickel foams showed highly positive correlations with Tb.Th and Tb.Sp. The attenuation coefficient of the copper foam showed a highly negative correlation with Tb.Th and Tb.Sp, whereas that of the nickle foam showed a highly positive correlation with Tb.Th and Tb.Sp. These results advance our understanding of those previously reported by other researchers using trabecular bone samples or phantoms.

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Characteristics of Biological Hydrogen Production from Sewage Sludge treated by Optimal Solubilization Technology (최적 가용화 기술로 처리된 하수슬러지의 생물학적 수소 생산 특성)

  • Choi, Kwang-Keun;Kim, Sun-Jip;Lee, Tae-Joon;Park, Dae-Won;Lee, Won-Kwon
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.353-359
    • /
    • 2006
  • The purpose of this study is to search the optimal solubilization technology which could be applied to sewage sludge, and is to find the characteristics of biological hydrogen production when the sludge treated by optimal method was used as a sole substrate. As a result of the test, treatment technology mixed with alkali and ultrasonic treatment was very powerful tool for treating sewage sludge with high solubilization, and its ratio and elution rate of organic material was 0.9 and 0.076 $min^{-1}$, respectively. When the sludge treated by above optimal technology was used, 4.4 ml $H_2/g$ VSS of hydrogen was produced. Finally, When the sludge treated by above optimal technology was used, 13.4 ml $H_2/g$ VSS of hydrogen was produced under optimum pH.