• Title/Summary/Keyword: Ultrasonic method

Search Result 2,085, Processing Time 0.027 seconds

Automatic Boundary Detection of Carotid Intima-Media based on Multiresolution Snake (다해상도 스네이크를 통한 경동맥 내막-중막 경계선 자동추출)

  • Lee, Yu-Bu;Choi, Yoo-Joo;Kim, Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.14A no.2
    • /
    • pp.77-84
    • /
    • 2007
  • The intima media thickness(IMT) of the carotid artery from B mode ultrasound images has recently been proposed as the most useful index of individual atherosclerosis and can be used to predict major cardiovascular events. Ultrasonic measurements of the IMT are conventionally obtained by manually tracing interfaces between tissue layers. The drawbacks of this method are the inter and intra observer variability and its inefficiency. In this paper, we present a multiresolution snake method combined with the dynamic programming, which overcomes the various noises and sensitivity to initialization of conventional snake. First, an image pyramid is constructed using the Gaussian pyramid that maintains global edge information with smoothing in the images, and then the boundaries are automatically detected in the lowest resolution level by minimizing a cost function based on dynamic programming. The cost function includes cost terms which are representing image features and geometrical continuity of the vessel interfaces. Since the detected boundaries are selected as initial contour of the snake for the next level, this automated approach solves the problem of the initialization. Moreover, the proposed snake improves the problem of converging th the local minima by defining the external energy based on multiple image features. In this paper, our method has been validated by computing the correlation between manual and automatic measurements. This automated detection method has obtained more accurate and reproducible results than conventional edge detection by considering multiple image features.

Study on the Hardness Measurement of Earthenware : Focusing on the Cup of the Baekje (토기의 경도측정법 연구: 백제시대 배(杯)류를 중심으로)

  • Moon, Eun-Jung;Kang, Hee-Jun;Kim, Su-Kyoung;Lee, Han-Hyoung;Hong, Jong-Ouk;Hwang, Jin-Ju
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.431-438
    • /
    • 2009
  • We have investigated the suitable measuring method and condition on the hardness testing for the earthenwares excavated from Poongnap mud castle in Hanseong Baekje period. The earthenwares which used on hardness testing have been classified according to Mohs hardness and external form and color. The Ultrasonic and Equotip testing method have used to the hardness testing on the surface of the earthenwares and the Rockwell and Micro-vickers testing methods have used to the hardness testing on the cross section of the earthenwares. As the results, the two methods applied to the surface of the earthenwares were very hard on the precise measurement and the measuring values were incompatible with the tendency classified according to Mohs hardness and external form and color. On the testing for the cross section of earthenware, the Rockwell-superficial hardness testing method was more suitable for the soft texture earthenware and highest reproducibility of the measuring value obtained at the test load and indentor are 15kgf and 1/16 “iron ball, respectively. The Micro-Vickers hardness testing method was suitable for the hard texture earthenware and highest reproducibility and accuracy of the measuring value obtained at the test load is 100gf. This results show strong possibility of progress on the classifying and comparing study for hardness of the earthenware and therefore active studies are expected on the field.

  • PDF

A study on the slip-up speed of a shaft using heating slip form (히팅슬립폼을 적용한 수직구 구조물의 상승속도에 관한 연구)

  • Ko, Eomsik;Lee, Sanghun;Park, Jongpil;Zi, Goangseup;Kim, Changyong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.811-823
    • /
    • 2019
  • Slip form method is applied to many cases of a shaft these days because it is safer, more economical and faster than cast-in-place method. Slip-up height of the method is approximately 2.5 to 4.0 m/day. If the temperature of concrete is outside the range of 10 to 30℃, the effects of changes in strength or elastic characteristics are significant. Therefore, it is difficult for slip-up speed to be higher than 3 m/day during winter construction. In addition, concrete has heat caused by hydration, which causes temperature cracking of hardened concrete. Therefore, temperature control of concrete curing is necessary for the continuous slip-up of slip form. In this study, the rebound hardness, time of ultrasonic waves propagation, heat of hydration, and external temperature are measured by developing heating panels and test devices for the continuous slip-up. Based on this, heating slip form is manufactured; this was applied to "Kimpo sites" and "Sinwol sites". The compared slip-up speed samples were 1.9 m/day or 0.200 m/hr on average at Gimpo sites (08:00~17:30) and 2.0 m/day or 0.210 m/hr at Sinwol sites.

A Pilot Study on Emissions of Air Pollutants Produced from Incineration of Some Municipal Solid Wastes

  • Kim, Haen-Gah;Lee, Byeong-Kyu;Cho, Jung-Bum
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E2
    • /
    • pp.49-56
    • /
    • 2006
  • This pilot study focuses on emissions characterization of air pollutants produced from incineration of some municipal solid wastes (MSWs). The MSWs incinerated by an electric furnace maintained up to $600^{\circ}C$ included food, paper, and plastic wastes. The pollutants analyzed in this study included concentrations of volatile organic compounds (VOCs), bottom ash contents, and heavy metals extracted from the bottom ash of each waste. The VOCs identified were classified based on their chemical structure. The total emissions of VOCs produced from incineration of the papers were identified as the highest followed by those from the plastics and the food wastes. Aliphatic alkenes were major VOC compounds produced from incineration of plastic or food wastes, while furans were major VOCs produced from incineration of papers. The second major VOCs produced from incineration of food, plastics, and papers were aromatics. In particular, hazardous air pollutants such as benzene were produced with considerable amount of emission concentration. The bottom ash contents of papers were usually much higher than those of food or plastic wastes. The bottom ash contents produced from incineration of food and plastics were much lower than those of other MSWs. In analysis of heavy metals extracted by an ultrasonic method from the bottom ashes of the papers, high concentrations of heavy metals were identified from incineration of newspapers and box (cardboard). In addition, it was identified that the general public might be exposed to considerable amounts of lead concentrations during incineration processes and uses of paper cup and from ashes.

Synthesis of Metal Oxide-Coated Conductive Metal Powders and Their Application to Front Electrodes for Solar Cells (산화물이 코팅된 전도성 금속 분말의 제조 및 태양전지 전면 전극으로의 응용)

  • Park, Jin Gyeong;Lee, Young-In
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.502-507
    • /
    • 2014
  • Recently, improvement in the conversion efficiency of silicon-based solar cells has been achieved by decreasing emitter doping concentration, because the lightly doped emitter can effectively prevent the recombination of electrons and holes generated by solar light irradiation. This type of emitter is very thin due to the low doping concentration, thus conductive materials (i.e., silver) used for front electrodes can easily penetrate the emitter during a firing process because of their large diffusivity in silicon. This results in junction leakage currents which might reduce cell efficiencies. In this study, $Al_2O_3$-coated Ag powders were synthesized by an ultrasonic spray pyrolysis method and applied to the conductive materials of the front electrode to control the junction leakage current. The $Al_2O_3$ shell obstructs the Ag diffusion into the emitter during the firing process. The powder is spherical with a core-shell structure and the thickness of the $Al_2O_3$ shell is tens of nanometers. Solar cells were fabricated using pure Ag powders or the $Al_2O_3$-coated Ag powder as front electrode materials, and the conversion efficiency and junction leakage current were compared to investigate the role of the $Al_2O_3$ shell during the firing processes.

Survey of Demand for Medical Devices in Korean Medicine (한방의료기기 개발 수요에 대한 조사연구)

  • Kim, Ji Hye;Kim, Keun Ho;Kim, Jaeuk U.
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.103-115
    • /
    • 2014
  • Objectives: The purpose of this survey was to investigate the need for new medical devices based on opinions of members of the Korean medical society. Methods: We distributed two independent questionnaires sequentially over two-week intervals to 16,510 doctors via the Korean Medical Society, and received replies from 888 and 928 doctors, respectively. The survey was carried out through a web-based questionnaire system. The first questionnaire focused on demand for new diagnostic and therapeutic medical devices that are specific for Korean medicine (KM). In contrast, the second questionnaire focused on demand for new hybrid medical devices which are useful both in Western medicine (WM) and KM. Results: In purchase intention of Korean medical devices (KMDs), demand for diagnostic devices was greater than for therapeutic ones. Among diagnostic devices, the purchase intention of 'imaging devices' ranked the highest and was followed by 'musculoskeletal diagnostic devices'. Among therapeutic KMDs, the purchase intention of 'musculoskeletal treatment devices' ranked the highest, followed by 'cranial nerve rehabilitation devices'. In the purchase intention of hybrid medical devices that can be used both in WM and KM, 'ultrasonic-based medical device' ranked the highest, followed by 'MRI-based medical device'. Conclusions: There is increasing demand for clinically useful medical devices among Korean medical doctors. Within demand for new devices, hybrid devices that can be used in both WM and KM were most strongly desired. This survey will be useful in establishing strategic plans for the development of medical devices in KM. Keywords: Korean medicine, medical device, demand survey, questionnaire.

Design of Path Weighting Data Analysis System for Efficient Product Arrangement (효율적인 상품 배치를 위한 경로 가중치 데이터 분석 시스템 설계)

  • Kim, Bong-Hyun
    • Journal of Digital Convergence
    • /
    • v.14 no.10
    • /
    • pp.167-172
    • /
    • 2016
  • Commercial analysis has been used for a lot of reasons such as improving the distribution structure, operational cost savings. However, existing commercial assay system is mostly flow through the analysis of the population and the environment around the store. Therefore, in this paper, we design a path weighted data analysis system for efficient product arrangement. It is not applying the analysis method of the existing commercial sales center but the data analysis system applying the weight to the form of customers' paths in a store. In conjunction with the existing POS system, it provides effective product placement in department stores, such as supermarkets, convenience stores. To this end, a system that maximizes efficiency of product placement in stores, receiving path data, converting them into statistics data that apply the weight, and printing out them into a visualized monitering system for the manager to see was designed.

Study on the Development of Working Safety Device for Visually Impaired Person (시각장애인 보행안전장치 개발에 관한 연구)

  • Kim, Hyo-Gwan;Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.4
    • /
    • pp.366-372
    • /
    • 2016
  • This paper advances the software, hardware and mechanical design that the visually impaired can recognize the position and distance of the obstacle while walking. The first software implementation is proposed a method to implement the algorithm graph for the ratio of the distance measuring ultrasonic sensors for voltage. And it was extracted by the precise distance measuring parameter values from simulation to measure the precise distance. Second hardware implementation was designed to be able to detect obstacles in a relatively simple sensor-based walking aid for the visually impaired. In addition, using the switching regulator IC of high performance it was designed to be used to boost the Li-ion battery 3.7V to 5V. The third mechanism was developed by analyzing the sensor angle and the cane angle.

A Study about Measurement Method for Quantitative Classification of Breeding Pig's Locomotor Behaviors using Ultrasonic Sensor Array (초음파 센서 어레이를 이용한 모돈 지제이상 정량분석 방법 연구)

  • Cho, Jinho;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.163-163
    • /
    • 2017
  • 모돈은 교배, 임신, 분만, 포유, 이유를 순환적 반복을 요구하는 개체로서 스마트 농장 시스템의 생산성 향상에 있어서 중요한 요소이다. 본 연구에서는 모돈 능력의 극대화 및 최적의 시스템 관리를 위해서 초음파 센서를 활용한 모돈의 지제 이상 징후를 실시간으로 계측할 수 있는 시스템을 개발하였다. 이 시스템은 높이에 따라 상-중-하(30 cm 간격), 위치에 따라 전면부-후면부에 초음파 센서를 설치하고 이를 마이크로 컨트롤러에 연결하여 모돈의 지제 이상 유무 측정이 가능하도록 하였다. 모돈의 체형과 위치를 고려하여 설치된 초음파 센서의 위치 조절이 가능하도록 하였다. 또한 소형 LCD 모듈을 내장하여 실시간 모니터링이 가능하도록 하였으며, 측정된 데이터는 저장장치인 microSD 카드에 저장되도록 하였다. 모돈사의 환경을 고려하여 방밀형 구조로 하우징 마감하였다. 이 모돈 지체 이상 분석 시스템에 사용된 툴은 C언어를 이용하였다. 건강한 모돈을 대상으로 모돈의 지제의 관찰을 위하여 총 12회의 현장 실증실험이 수행되었으며, 현장 실증 시험 중 소요된 시간은 현장의 상황에 따라 다소 상이하였다 (8시간-28일). 높이 상에 위치한 전면부 및 후면부 초음파 센서 모두에서 모돈이 검출이 된 경우 정상 기립으로 간주하였고, 높이 상에 위치한 전면-후면부 초음파 센서 모두에서 모돈이 검출이 되지 않은 경우 정상적으로 누워 있는 걸로 간주하였다. 높이 하에 위치한 전면부 혹은 후면부 초음파 센서 한곳만 모돈이 검출된 경우 비정상적인 기립으로 간주하였다. 취득된 데이터를 분석한 결과 모돈의 정상적 상태 (기립상태, 누운 상태, 앉은 상태)와 그 외의 비정상적 상태로 분류가 가능하다. 또한 측정된 초음파 센서의 진동의 유무 및 파동형태에 따라서 모돈의 상태 예측이 가능하다. 초음파 센서의 진동 파동이 크고 안정된 상태인 경우 정상적인 활동 상태로 판단하였으며, 진동 파동이 작고 안정적인 경우는 수면 상태로 분류하였다. 실시간으로 지속적인 데이터 획득을 위하여 차후 초음파 센서 및 시스템의 보완작업이 필요하다. 이와같은 모돈의 행동 패턴에 따른 취득된 데이터를 분류하여 모돈의 발정에 의한 행동 특성(기립시간) 분석에 따른 발정 적기 발견 및 정량화 기술 개발에 활용이 가능하다.

  • PDF

Behavior of ultrasonic transducer in air by using finite element method simulation (FEM 시뮬레이션을 이용한 공기 중에서의 초음파 트랜스듀서의 거동)

  • Chae, Yeon-Hwa;Choi, Kyoon;Lee, Ho-Yong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.5
    • /
    • pp.185-190
    • /
    • 2018
  • The Tonpilz transducer was implemented using the structural module of COMSOL which is a FEM simulation tool. In order to compare the sound pressure characteristics of the transducer with the simulated results, the spacial distribution of the sound pressure level (SPL) was simulated by the acoustic module of COMSOL and then compared with the SPL distribution measured by a microphone. As a result, the resonance frequency and the peak in SPL for the simulation were predicted to be 28 kHz and 163.5 dB, respectively. And the resonance frequency and the peak in SPL for the actual transducer were measured to be 28.84 kHz and 137.8 dB, respectively. It is also confirmed that the simulated SPL distribution and the actually measured one are formed in a similar pattern.