• Title/Summary/Keyword: Ultrasonic measurement method

Search Result 441, Processing Time 0.023 seconds

A Study about the Construction of Intelligence Data Base for Micro Defect Evaluation (미소 결함 평가를 위한 지능형 데이터베이스 구축에 관한 연구)

  • 김재열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.585-590
    • /
    • 2000
  • Recently, It is gradually raised necessity that thickness of thin film is measured accuracy and managed in industrial circles and medical world. Ultrasonic Signal processing method is likely to become a very powerful method for NDE method of detection of microdefects and thickness measurement of thin film below the limit of Ultrasonic distance resolution in the opaque materials, provides useful information that cannot be obtained by a conventional measuring system. In the present research, considering a thin film below the limit of ultrasonic distance resolution sandwiched between three substances as acoustical analysis model, demonstrated the usefulness of ultrasonic Signal processing technique using information of ultrasonic frequency for NDE of measurements of thin film thickness, sound velocity, and step height, regardless of interference phenomenon. Numeral information was deduced and quantified effective information from the image. Also, pattern recognition of a defected input image was performed by neural network algorithm. Input pattern of various numeral was composed combinationally, and then, it was studied by neural network. Furthermore, possibility of pattern recognition was confirmed on artifical defected input data formed by simulation. Finally, application on unknown input pattern was also examined.

  • PDF

Measurement of Ferrite Grain Size by Ultrasonic Method in Low Carbon Steel (초음파법에 의한 저탄소강의 페라이트 결정립 크기 측정)

  • Hong, Soon Taik;Kwun, Sook In;Choo, Wung Yong
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.157-165
    • /
    • 1999
  • Grain size of steels is one of the most important parameters which influence yield strength and fracture toughness. Ultrasonic wave propagating in polycrystalline materials is mostly attenuated by scattering at grain boundary. Effect of ultrasonic attenuation on average ferrite grain size of carbon steels with tensile strength $40{\sim}60kgf/mm^2$ consisting of multi phases such as ferrite + pearlite and ferrite + pearlite + bainite was evaluated. The attenuation of these steels rapidly increased with average ferrite grain diameter. Average ferrite grain diameter ($D_{av}$, ${\mu}m$) could be expressed as $1.79+22.97*a^{1/2.03}$, where a is attenuation with unit of nepers/cm. From this study, it was confirmed that nondestructive ultrasonic method could be used in measuring average ferrite grain size indirectly.

  • PDF

A Study on the Atomization of a Highly Viscous Biodiesel Oil (고점성 바이오 디젤유의 분무미립화에 관한 연구)

  • 주은선;정석용;강대운;김종천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.146-153
    • /
    • 1997
  • An experiment was conducted to figure out the atomization characteristics of a highly viscous biodiesel fuel with rice-barn oil applying and ultrasonic energy into it. A spray simulator for the droplet atomization, an ultrasonic system, and six different nozzles(3 pintle-type nozzles and 3 single hole-type nozzles) were made. To investigate effects of ultrasonic energy in a highly viscous liquid fuel, an immersion liquid method was used as a measurement method on droplet size distributions. It was found that the ultrasonic energy was effective for the atomization improvement of the rice-bran oil as a highly viscous biodiesel fuel and the factor나 such as the nozzle opening pressure, pin-edge angles, hole diameters, and collection distances affected the atomization of spray droplets.

  • PDF

Strength Evaluation of Adhesively Bonded Single-Lap Joints by Ultrasonic Signal Analysis (초음파신호해석을 이용한 단순겹치기 접착이음의 강도평가)

  • Oh Seung-Kyu;Jang Chul-Sub;Han Jun-Young;Lee Won
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.32-37
    • /
    • 2004
  • Application of bonding by adhesives can be found in many industries, particularly in advanced technological domains such as aeronautical and space, automobile and electronics industries. Periodic inspection with conventional ultrasonic NDE techniques is capable of indicating the presence and possible location of crack. Continuous ultrasonic attenuation monitoring has potential to supply information. This article discusses the use of pulse-echo ultrasonic testing for the inspection of adhesive bonds between metal sheets. The method is based on the measurement of the reflection coefficient at the metal/adhesive interface. By means of a control experiment it is shown that Quantitative Nondestructive Evaluation in Adhesive Joints are evaluated together with Ultrasonic Testing and Fracture Testing.

Ultrasonic Scatter and Compensation of Interfacial Crack due to Thickness Variation of Dissimilar Bonded Components (이종 접합부재의 두께 변화에 따른 계면균열의 초음파 산란 보정)

  • Park, Sung-Il;Chung, Nam-Yong;Jin, Yoon-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.25-30
    • /
    • 2004
  • In this paper, the compensation of interfacial scatter due to adhesive layer and adherend thickness ratio variation was applied to improve measuring precision by calculating ultrasonic attenuation coefficient in the Al/Epoxy dissimilar bonded components. The optimum condition of theoretical value and experimental measuring accuracy by the ultrasonic method in the Al/Epoxy dissimilar bonded components have been investigated. From the experimental results, we proposed a measurement method of the interfacial crack lengths by the ultrasonic attenuation coefficient and discussed it.

  • PDF

In-line measurement of residence time distribution in twin-screw extruder using non-destructive ultrasound

  • Lee, Sang-Myung;Park, Jong-Cheol;Lee, Sang-Mook;Ahn, Young-Joon;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.2
    • /
    • pp.87-95
    • /
    • 2005
  • In this study, we performed RTD measurement at the die exit of co-rotating twin-screw extruder using a non-destructive ultrasonic device. The ultrasonic device was attached at slit die and was composed of a steel buffer rod and 10 MHz longitudinal piezoelectric ultrasonic transducer. This in-line ultrasonic monitoring method is based on the ultrasonic response of $CaCO_3$ filled in polymer. The RTD is evaluated by variation of ultrasonic attenuation with time caused by change of the tracer concentration during extrusion. The ultrasonic tracer, pellet type of compounded $CaCO_3$ in polymer was used in this study. The effects of tracer concentration on RTD and flow patterns were studied. Evaluation for the residence functions at different screw speeds, feeding rates and screw configurations were also carried out.

Measurement of the Crack Height using the Two-Probe Ultrasonic Diffraction Method. (초음파회절방법(超音波回折方法)을 이용한 귀렬(龜裂)의 높이 측정(測定))

  • Lee, Jae-Ok;Lee, Seung-Kyu;Kim, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.35-41
    • /
    • 1988
  • The optimum test conditions of measuring the crack height were determined for the two-probe ultrasonic diffraction method. The applicability and the accuracy of the two-probe ultrasonic diffraction method on the inclined artificial cracks and the fatigue cracks were evaluated. It us possible to measure the height of the normal and inclined artificial cracks with the maximum error of ${\pm}\;0.5mm$ with the two-probe ultrasonic diffraction method. It was found, however, that the accuracy of this method in meaasuring the height of the fatigue crack depends on the degree of closure of the crack tip. It was desirable to choose a refraction angle as small as possible, but the angle should not be so small that the distortion of the lateral waveform became appreciable.

  • PDF

Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor (초음파센서를 이용한 냉중성자원 수직공 형상측정)

  • Park, Guk-Nam;Choe, Chang-Ung;Sim, Cheol-Mu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

In Vivo Doppler-Based Measurement of Bending Vibration Velocity in Liver Vibrated by Lo7v Frequency Signal (초음파 Doppler법에 의한 비침투적인 생체조직의 진동속도 계측)

  • 박무훈;장윤석
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.407-412
    • /
    • 1997
  • In this paper, we present a new method to diagnose the characteristics of the soft tissue, especially a liver. In order to diagnose the characteristics of a liver, it is necessary to evaluate the propagation delay time and propagation velocity of bending vibration In a liver. For this purpose, we measure the propagation velocity of bending vibration in a liver for low frequency forced vibration using a standard ultrasonic Doppler diagnosis equipment. We have carried out preliminary experiments by using an ultrasonic probe of 3.5MHz and obtained some results. This new measurement method developed here can be applied to new research and medical fields for acoustic non-invasive diagnosis of soft tissue.

  • PDF

A Study on Method for Improving Reproducibility in the Ultrasonic Measurement of Bone Mineral Density (초음파 골밀도 측정에서 재현성 향상 방법에 관한 연구)

  • Shin, Jeong-Sik;Ahn, Jung-Hwan;Kim, Hwa-Young;Kim, Hyung-Jun;Han, Seung-Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.10 s.241
    • /
    • pp.1430-1437
    • /
    • 2005
  • It is very important to achieve a high reproducibility in the ultrasonic measurement of bone mineral density. In this study, we examined number of sampling waveform, control of temperature, diameter of region of interest as factors to improve reproducibility. We decided the optimal number of waveforms to be converted to frequency domain as period of 1. We have minimized the effects of variable temperature and constrained generation of micro bubble by keeping temperature within a range of $32\pm0.5^{\circ}C$ with a precise temperature controlling algorithm. We also found the optimal diameter of region of interest to be 13mm. In this paper, we demonstrated the improved reproducibility by controlling various factors affecting the ultrasonic measurement of bone mineral density.