• Title/Summary/Keyword: Ultrasonic measurement method

Search Result 441, Processing Time 0.024 seconds

Nondestructive evaluation of spot weld quality using by ultrasonic measurement (초음파계측에 의한 SPOT용접품질의 비파괴평가)

  • 박익근
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 1994
  • Spot welding has wide used with a high work efficiency in the automotive and aerospace industries. Up to the present, the technique mainly used to test spot welds on production lines has been entirely depended upon destructive chisel or peel testing. Therefore, it's being very important assignment to secure the NDE technique which can be evaluate spot weld quality with more efficiency and high reliability. This paper discusses the feasibility of UNDE techniques to evaluate spot weld quality. For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of a the corona bond from nugget, ultrasonic c-scan image and distribution of reflective echo amplitude was measured by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). As the results of this study, corona bond which is the most dangerous types of interface defects can be successfully detected, as well as expulsion and voids. Ultrasonic testing results were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be successfully measured with the accuracy of 0.8 mm.

  • PDF

Study on the development of ultrasonic gas flowmeter (초음파 가스 유량계 개발 연구)

  • Hwang, Won-Ho;Park, Sang-Gug;Yang, Kyu-Hong;Jhang, Kyung-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.76-81
    • /
    • 2001
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has already well been proven by extensive field tests for several months in POSCO, iron & steel making company.

  • PDF

Recognition of Object Position by use of Aerial Ultrasonic Sensor

  • Kashiwagi, H.;Kaba, K.;Yamaguchi, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.70-74
    • /
    • 1998
  • This paper describes a method for recognition of two-dimensional position of an object by use of aerial ultra-sonic sensor and signal processing technique, which would become a help for blind person or self-mobile robot. First, we have developed a method for measuring the time difference between the transmitted and the received burst wave by use of one ultrasonic transmitter and three receivers. Secondly, a new method is developed for measuring the distance to an object by use of M-sequence correlation method. Thirdly, a measurement method to obtain the position of an object is described by use of phase-arrayed ultrasonic sensor, which gives us a wide-range position determination in a short time.

  • PDF

A Study on the Measurement of Foreign Material in Dissimilar Metal Contact Using Pulse Laser and Confocal Fabry-Perot Interferometer (펄스 레이저와 CFPI를 이용한 이종금속 접촉부의 이물질 측정에 관한 연구)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.160-164
    • /
    • 2013
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasonics by using laser beam. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this study, galvanic corrosion phenomenon was measured by non-destructive and non-contact method using the laser. The case of mixed foreign material on the part of corrosion was assumed and laser ultrasonic experiment was conducted. Ultrasonic was generated by pulse laser from the back side of the specimen and ultrasonic signal was acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer(CFPI). The characteristic of the ultrasonic signal of exist foreign material part was analyzed and the location and size of foreign material was measured.

Non-destructive Inspection of Top-Down Construction Joints of Column in SRC Structure using Ultrasonic Method (초음파법을 이용한 콘크리트 역타시공 이음부 공극의 화상검출특성)

  • Park, Seok-Kyun;Baek, Un-Chan;Lee, Han-Bum;Kim, Myoung-Mo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.290-295
    • /
    • 2000
  • The joint treatment of concrete is one of the technical problems in top down construction method. Joints created with the top down construction result in serious weakness from the aspects of both structural and water-barrier function. Ultrasonic method was used for the inspection of top down construction joints of a various column in SRC structure in this study. The advantages and limitations of this method for non-destructive inspection in top down construction joints are investigated. As a result, it has been verified that the semi-direct measurement method is more effective than the other methods for detecting the voids of construction joints using ultrasonic method.

  • PDF

The optical measurement and wavelet analysis about ultrasonic signals by discharge in oil (유중방전 초음파 신호의 광학적 측정 및 wavelet 분석)

  • Lee, S.H.;Lee, H.C.;Jee, S.W.;Kim, Ch.N.;Song, H.J.;Lee, K.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.298-303
    • /
    • 2004
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based rut the needle-plane electrode system in oil and applied AC high voltage Ultrasonic waves were detected and showed signal- analysis results with wavelet transform.

  • PDF

Stydy of Pool Boiling under Steady State using Ultrasonic Measurement (초음파 측정법을 이용한 정상상태의 푸울비등 연구)

  • 장길홍
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.35-40
    • /
    • 1992
  • A recently developed new technique for measuring the fraction of wetted area has applied to pool boiling of water. The basis of the new applied technique of ultrasonic makes use of the reflection of ultrasonic from the vapour surface to measure the fraction of wetted area values. The results are the measured fraction of wetted area values in nucleate and transition boiling and the pool boiling curve for water under steady state conditions. The measurement of this paper shows a fraction of wetted areaf around 0.98 at the critical heat flux for water.

  • PDF

Detection of Tool Wear by Using the Ultrasonic in-Process Sensor (초음파 인프로세스 센서를 이용한 공구마멸 검출)

  • Kang, H. S.;Chung, E. S.;Hwang, J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.852-856
    • /
    • 1997
  • This paper describes a ultrasonic method for direct measurement of tool wear in turning operations. An integrated single ultrasonic transducer operating at a frequency of 10MHz is placed in contact with the insert tip. The change in amount of the reflected energy form the nose and flanks of the tool can be related to the level of tool wear and thr mechanical integrity of the tool. As a results, a correlation exists between the untrasonic measurement and tool wear and that it is tool dependent.

  • PDF

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

Parameter Estimation of Tissue Structure Characteristics in Ultrasound Measurement (초음파를 이용한 조직구조 특성변수의 측정)

  • 곽철은;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 1986
  • The objective of tissue characterization is to provide quantitative information about the physical state of tissue interrogated by an ultrasound beam. In the computer simulation, it was found that the echoes were composed of the interferences of the ultrasonic waves reflected from both sides of the thin object, and could be separated by the spectral correlation method. Also, the phantom study demonstrates that thickness of the thin acryl layer beyond the resolution of common ultrasonic imaging systems can be measured- using this method.

  • PDF