• 제목/요약/키워드: Ultrasonic measurement method

검색결과 441건 처리시간 0.028초

주기인식 검출방식을 이용한 장거리 정밀 초음파 거리측정 시스템 개발 (A Long Range Accurate Ultrasonic Distance Measurement System by Using Period Detecting Method)

  • 이동활;김수용;윤강섭;이만형
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.41-49
    • /
    • 2007
  • In this paper, we proposed a new ultrasonic distance measurement system with high accuracy and long range. To improve accuracy and enlarge range, the time of flight of ultrasonic is calculated by the period detecting method. In the proposed ultrasonic distance measurement system, the ultrasonic transmitter and receiver are separated but synchronized by RF(Radio frequency) module. The experiment has been implemented from short distance 1m to maximum available distance 30m. And the period detecting method is compared with the conventional threshold level method. Experimental results show the accuracy and range of the distance measurement are improved by this period detecting method.

Development of the Ultrasonic Method for Two-Phase Mixture Level Measurement

  • Lee, Dong-Won;No, Hee-Cheon;Song, Chul-Wha;Jeong, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.124-124
    • /
    • 1999
  • An ultrasonic method is developed for the measurement of the two-phase mixture level in the reactor vessel or steam generator. The ultrasonic method is selected among the several non¬nuelear two-phase mixture level measurement methods through two steps of selection procedure. A commercial ultrasonic level measurement method is modified for application into the high temperature, pressure, and other conditions. The calculation method of the ultrasonic velocity is modified to consider the medium as the homogeneous mixture of air and steam. and to be applied into the high temperature and pressure conditions. The cross-correlation technique is adopted as a detection method to reduce the effects of the attenuation and the dif.JUsed reflection caused by suface fluctuation. The waveguides are developed to reduce the loss of echo and to remove the effects of obstructs. The present experimental study shows that the developed ultrasonic method measures the two-phase mixture level more accurately than the conventional methods do.

  • PDF

평면 LED 램프에서의 초음파 센서의 반사특성을 고려한 위치측정 기법 (Location Measurement method Depending on Reflection Characteristics of Ultrasonic Sensors for The Flat LED Lamp)

  • 허영록;윤장희;염정덕
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.38-43
    • /
    • 2013
  • In this paper, the location measurement method for the reliable location data using ultrasonic sensors is proposed for the dimming control of the LED flat lamp. The measurement errors depending on the reflection angle of the object have to be considered to obtain the reliable location data in the ultrasonic sensors. In the experiment, the cause of the measurement errors depending on reflection angle is analyzed and velocity change of ultrasonic wave depending on reflection angle is measured. And the location measurement method depending on velocity change of ultrasonic wave is proposed. From the results, the average absolute deviation of the x-coordinates was 1.47cm when the location measurement method was considered, and it was closer to the true values than the average absolute deviation of the x-coordinates which was 5.89cm without regard to the reflection angle.

평면 초음파를 이용한 미소 간극 측정 (Thickness Measurement of A Thin Layer Using Plane Ultrasonic waves)

  • 김노유
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.415-418
    • /
    • 1995
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave using ultrasonic pulse-echo method. The technique determines the thickness of a thin layer in a layered medium form the amplitudes of the total reflected waves from the back side layer of interst. Thickness of a very thin layer few inch deep inside the media can be measured without using a very high frequency ultrasonic transducer over 100MHz which must be used in the conventional techniques for the precision measurement of a thin layer. The method also requires no inversion process to extract the thickness from the waveform of the reflected waves, so that it makes possible on-line measurement of the thickness of the layer.

  • PDF

저어널 베어링의 진동 계측을 위한 초음파 응용 기술에 관한 연구 (A Study on the Ultrasonic Technique for Measurement of Vibration in Journal Bearing)

  • 김노유
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.476-481
    • /
    • 1999
  • This paper describes a new technique for measurement of the displacement less than one-quarter of the wavelength of ultrasonic wave using ultrasonic pulse-echo method. The technique determines the displacement of a journal bearing from the amplitudes of the total reflected waves from the surface of journal inside the bearing. Vibration of journal bearing can be measured without using a very high frequency ultrasonic transduce over 100MHz which must be used in the conventional techniques for the precision measurement of a small displacement. The method also requires no inversion process to extract the thickness from the waveforms of the reflected waves, so that it makes possible on-line measurement of the vibration of journal bearing.

  • PDF

Measurement of Elastic Constants by Simultaneously Sensing Longitudinal and Shear Waves as an Overlapped Signal

  • Seo, Hogeon;Song, Dong-Gi;Jhang, Kyung-Young
    • 비파괴검사학회지
    • /
    • 제36권2호
    • /
    • pp.138-148
    • /
    • 2016
  • Measurement of elastic constants is crucial for engineering aspects of predicting the behavior of materials under load as well as structural health monitoring of material degradation. Ultrasonic velocity measurement for material properties has been broadly used as a nondestructive evaluation method for material characterization. In particular, pulse-echo method has been extensively utilized as it is not only simple but also effective when only one side of the inspected objects is accessible. However, the conventional technique in this approach measures longitudinal and shear waves individually to obtain their velocities. This produces a set of two data for each measurement. This paper proposes a simultaneous sensing system of longitudinal waves and shear waves for elastic constant measurement. The proposed system senses both these waves simultaneously as a single overlapped signal, which is then analyzed to calculate both the ultrasonic velocities for obtaining elastic constants. Therefore, this system requires just half the number of data to obtain elastic constants compared to the conventional individual measurement. The results of the proposed simultaneous measurement had smaller standard deviations than those in the individual measurement. These results validate that the proposed approach improves the efficiency and reliability of ultrasonic elastic constant measurement by reducing the complexity of the measurement system, its operating procedures, and the number of data.

두개의 탐촉자를 사용한 등방성 균일 고체의 초음파 속도 및 두께 동시 측정법 (Simultaneous Measurement of Ultrasonic Velocity and Thickness of Isotropic and Homogeneous Solids Using Two Transducers)

  • 이정기;권진오;김영환
    • 비파괴검사학회지
    • /
    • 제19권5호
    • /
    • pp.363-368
    • /
    • 1999
  • 시험체의 두께나 초음파 속도를 측정하기 위해서 초음파 펄스-에코법이 널리 사용되고 있다. 초음파 속도를 결정하기 위해서는 초음파 송수신 장치를 포함한 오실로스코우프와 같은 초음파 측정 장치를 사용하여 시험편에서의 초음파진행 시간을 측정하고, 초음파 진행 거리에 해당하는 시험편의 두께를 버어니어 캘리퍼스 또는 마이크로미터와 같은 길이측정 도구를 사용하여 측정한다. 그리고 초음파를 이용하여 시험편의 두께를 측정할 때에는 초음파 속도를 알고 있는 대비 시험편으로 기준을 설정하여야 한다. 본 연구에서는, 대비 시험편 없이 재료의 두께와 초음파 속도를 동시에 구하는 방법을 제시하였다. 재질과 두께를 달리한 여러 시험편에서 측정된 초음파 속도와 두께가 기존의 방법에 의해 측정한 값과 잘 일치하였다.

  • PDF

원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구 (A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants)

  • 유성식;박종호
    • 한국유체기계학회 논문집
    • /
    • 제6권1호
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

무인 이동 로봇 위치추정을 위한 초음파 위성 시스템 (USAT(Ultrasonic Satellite System) for the Autonomous Mobile Robots Localization)

  • 이동활;김수용;윤강섭;이만형
    • 제어로봇시스템학회논문지
    • /
    • 제13권10호
    • /
    • pp.956-961
    • /
    • 2007
  • We propose a new distance measurement method and local positioning system for the autonomous mobile robots localization. The distance measurement method is able to measure long-range distances with a high accuracy by using ultrasonic sensors. The time of flight of the ultrasonic waves include various noises is calculated accurately by the proposed period detecting method. The proposed local positioning system is composed of four ultrasonic transmitters and one ultrasonic receiver. The ultrasonic transmitter and receiver are separated but they are synchronized by RF (Radio frequency) signal. The proposed system using ultrasonic waves is represented as USAT(Ultrasonic Satellite System). USAT is able to estimate the position using the least square estimation. The experimental results show that the proposed local positioning system enables to estimate the absolute position precisely.

이동로봇의 거리측정을 위한 고성능 일체형 초음파 모듈 개발 (Development of Robust Single Ultrasonic Module for Distance Measurement of Mobile Robot)

  • 최종훈;심현민;유제군;이응혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.418-420
    • /
    • 2005
  • This paper proposed ultrasonic distance measurement module development for correct distance detection with collision escaping or obstacle of mobile robot is traveling self-regulation. Representative ultrasonic module applied in existing was Polaroid company's 6500 series and Devantech company's SRF04/SRF08 series. This ultrasonic sensors are corrupted by systematic errors due mainly to the dependency of sound speed upon surrounding conditions and random errors of uncertain origin. Therefore Ultrasonic distance detecting means of error compensation method and high definition, narrow beam angle, board area distance detecting means to apply to ultrasonic mobile robot control urgently need. In this paper use internal type temperature compensation method to improve problem of ultrasonic distance measurement method instead of that volume that have shortcoming of used correct temperature compensation methods applied big addition device. Compensate error by environment change of temperature. Humidity density etc. and is applicable to mobile robot offering various interface and real-time processing developed possible distance measurement module.

  • PDF