• Title/Summary/Keyword: Ultrasonic measurement

Search Result 835, Processing Time 0.028 seconds

Clinical Significance of the Degree of Fatty Liver Diagnosed by Ultrasonography (초음파검사로 진단된 지방간 정도의 임상적 의의)

  • Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • Purpose: Fatty liver is one of the most commonly found disease by abdominal ultrasonography. The status of fatty liver is classified into mild, moderate and severe degrees. The study was conducted to investigate the clinical significance of fatty liver using ultrasonography. Materials and method: Test set consisted of 2,185 patients who visited D healthcare center in Daejeon to receive an abdominal ultrasonic test from January to December 2007. Out of the 2185 patients, 524 patients was diagnosed as fatty liver (290 male and 234 female patients). They were divided into three groups, group I for mild degree. II for moderate degree, and III for severe degree, depending on the echo of liver parenchyma, the sound attenuation, and the visibility of intrahepatic blood vessels and diaphragm. Then the correlation of obesity indices, liver function tests and metabolic syndrome was analyzed for males and females separately. Results : As for the degree of fatty liver, 350 cases (66.8%) were classified as group I, 153 cases (29.2%) as group II, and 21 cases (4.1%) as group III. In addition, severe degree of fatty liver was more frequently found in males than in females. The mean ages of three groups for males were 46.1, 44.5, and 39.1, and those for females were 48.8, 50.2, 52.4, respectively. Males with lower mean ages have severely of fatty liver for both males and females. Conclusion: The results in this study show that the classification into three degrees of fatty liver in ultrasonography practice is helpful to treat and observe the progress of fatty liver. In addition, careful examination is required to measure the severity of fatty liver as well as detection of it. A standardized method to classify the degree of fatty liver is also needed for more objective measurement.

  • PDF

A Study on the Livestock Feed Measuring Sensor and Supply Management System Implementation based on the IoT (IoT 기반의 축산사료 측정 장치 및 사료 공급 시스템 구현)

  • An, Wonyoung;Chang, YunHi
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.442-454
    • /
    • 2017
  • As the demand for meat products has steadily increased in Korea, so the livestock industry has full grown. However, the opening of import meat products is taking a toll on the local industry. Cost reduction on livestock feed, which comprises the majority of costs involved in the industry is urgent to gain a competitive edge. As Internet of Things (IoT) technologies are being applied across a multiple of industries, so are the cases of applied Smart Farm technology for efficient production. The following research aims to utilize IoT technologies to measure, in real time, the rate of depletion of feed and remaining amount and to propose an effective automated reorder & delivery system. First, a method of utilization of ultrasonic and temperature/humidity sensors to obtain corresponding data of remaining feed in the Feedbin is proposed. In addition, a method of sending the obtained data via on-the-farm gateway to Supply Chain Management (SCM) servers is proposed. Finally, utilization of the stored data to construct an automated reorder & delivery service system is proposed. It is in the researcher's intention to contribute to and enable the local livestock industry with the application of various IoT services.

A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer (골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교)

  • Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.7-12
    • /
    • 2019
  • Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.

Feature Map Based Complete Coverage Algorithm for a Robotic Vacuum Cleaner (청소 로봇을 위한 특징점 맵 기반의 전 영역 청소 알고리즘)

  • Baek, Sang-Hoon;Lee, Tae-Kyeong;Oh, Se-Young;Ju, Kwang-Ro
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.81-87
    • /
    • 2010
  • The coverage ability is one of essential techniques for the Robotic Vacuum Cleaner (RVC). Most of the RVCs rely on random or regular pattern movement to cover a target space due to the technical difficulties to implement localization and map and constraints of hardwares such as controller and sensors. In this paper, we consider two main issues which are low computational load and using sensors with very limited sensing capabilities. First, in our approach, computing procedures to build map and detect the RVC's position are minimized by simplifying data obtained from sensors. To reduce computational load, it needs simply presenting an environment with objects of various shapes. Another isuue mentioned above is regarded as one of the most important problems in our approach, because we consider that many RVCs use low-cost sensor systems such as an infrared sensor or ultrasonic sensor with limited capabilities in limited range, detection uncertainty, measurement noise, etc. Methods presented in this paper are able to apply to general RVCs equipped with these sensors. By both simulation and real experiment, we evaluate our method and verify that the proposed method guarantees a complete coverage.

Increased Sensitivity of Carbon Nanotube Sensors by Forming Rigid CNT/metal Electrode

  • Park, Dae-Hyeon;Jeon, Dong-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.348-348
    • /
    • 2011
  • Carbon nanotube (CNT) field effect transistors and sensors use CNT as a current channel, of which the resistance varies with the gate voltage or upon molecule adsorption. Since the performance of CNT devices depends very much on the CNT/metal contact resistance, the CNT/electrode contact must be stable and the contact resistance must be small. Depending on the geometry of CNT/electrode contact, it can be categorized into the end-contact, embedded-contact (top-contact), and side-contact (bottom-contact). Because of difficulties in the sample preparation, the end-contact CNT device is seldom practiced. The embedded-contact in which CNT is embedded inside the electrode is desirable due to its rigidness and the low contact resistance. Fabrication of this structure is complicated, however, because each CNT has to be located under a high-resolution microscope and then the electrode is patterned by electron beam lithography. The side-contact is done by depositing CNT electrophoretically or by precipitating on the patterned electrode. Although this contact is fragile and the contact resistance is relatively high, the side-contact by far has been widely practiced because of its simple fabrication process. Here we introduce a simple method to embed CNT inside the electrode while taking advantage of the bottom-contact process. The idea is to utilize a eutectic material as an electrode, which melts at low temperature so that CNT is not damaged while annealing to melt the electrode to embed CNT. The lowering of CNT/Au contact resistance upon annealing at mild temperature has been reported, but the electrode in these studies did not melt and CNT laid on the surface of electrode even after annealing. In our experiment, we used a eutectic Au/Al film that melts at 250$^{\circ}C$. After depositing CNT on the electrode made of an Au/Al thin film, we annealed the sample at 250$^{\circ}C$ in air to induce eutectic melting. As a result, Au-Al alloy grains formed, under which the CNT was embedded to produce a rigid and low resistance contact. The embedded CNT contact was as strong as to tolerate the ultrasonic agitation for 90 s and the current-voltage measurement indicated that the contact resistance was lowered by a factor of 4. By performing standard fabrication process on this CNT-deposited substrate to add another pair of electrodes bridged by CNT in perpendicular direction, we could fabricate a CNT cross junction. Finally, we could conclude that the eutectic alloy electrode is valid for CNT sensors by examine the detection of Au ion which is spontaneously reduced to CNT surface. The device sustatined strong washing process and maintained its detection ability.

  • PDF

Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension (금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량)

  • Han, Chul-Woo;In, Gyo;Choi, Jong-Moon;Kim, Sun Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.608-615
    • /
    • 2000
  • A determination method of trace nickel and cobalt in water samples was studied and developed by adsorbing their complexes on ion exchange resin suspension. The analytical ions were formed as complexes with a ligand of APDC (ammonium pyrrolidinedithiocarbamate) and adsorbed on anion exchange resin of Dowex 2-X8. After the suspension was filtered out with membrane filter, the complexes were dissolved in HCl solution by an ultrasonic vibrator for ET-AAS determination. Several conditions were optimized as followings. pH of sample solution: 5.0, amount of ligand APDC: more than 430 times in mole ratio, the type and concentration of acid: 0.1 M HCl, and vibration time: 7 minutes. The addition of palladium in the HCl solution could improve the reproducibility and sensitivity by a matrix modification in the absorbance measurement. This procedure was applied for the analysis of three kinds of real water samples. The detection limits equivalent to 3 times standard deviation of blank were Co 0.36 ng/mL and Ni 0.27 ng/mL and recoveries in spiked samples were 99-102% for cobalt and 100-105% for nickel.

  • PDF

EFFECT OF ZIZYPHI FRUCTUS EXTRACT ON THE BIOLOGICAL ACTIVITY OF GINGIVAL FIBROBLAST (대조 추출물분획이 치은 섬유아세포의 생물학적 활성화에 미치는 영향)

  • Yang, Chang-Ho;Lee, Yong-Moo;Cho, Ki-Yeong;Bae, Ki-Hwan;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.144-154
    • /
    • 1994
  • Final goal of periodontal treatment is to reconstruct the destructed periodontal tissue as well as to remove the necrotic pathologic elements. The purpose of this study is to investigate on the effect of Zizyphi extract to the inhibitory ability on collagenolytic activity of P gingivalis, biologic activity of gingival fibroblasts, and on the collagen and protein synthesis of gingival fibroblasts. Gingival fibroblast from giniva of first bicuspids from patient for orthodontic treatment were used and cultured. For the measurement of inhibitory ability of collagenolytic activity, crude enzyme was extracted and used on the basis of modified Ono's method. On the inhibition of collagenolytic enzyme from herbal extracts, collagenokit CLN-100 were used. The cellular activity of gingival fibroblast, were studied using MTT solution and measured optical density on 570mm by ELISA reader. To measure the effects on the ability of whole protein and collagen synthesis, cell membrane was destructed with ultrasonic grinder after culturing, centrifuged and counted by liquid scintilation counter. The inhibitory effects on producing of $IL-l{\beta}$ by monocyte, after promotion of producing $IL-l{\beta}$ by LPS, were compared with the mixture of herbal extracts and other drugs using thymocyte stimulation assay. About inhibitory effects of $PGF_2$. by gingival fibroblasts, herbal extract was compared with the addition of the other control groups using enzyme imunoassay. On the inhibition of collagenolytic activity by P. gingivalis, benzene extracts showed the most efficient inhibitory effects among the $19{\mu}g/ml$ of the compared extracts and 40.5% by Tetracycline. On the cellular activity promoting effects, compared extracts showed a bit of more effects than PDGF of $100{\mu}g/ml$ concentration and IGF of $20{\mu}g/ml$ concentration. All of the PDGF, IGF, Zizyphi Fructus extract should increase in collagen synthesis, but especially 70% ethylalcohol extracts of Zizyphi Fructus showed comparably high effects among the compared extracts. Effects on whole protein synthesis were slightly increased on every extract but especially 70% ethylalcohol extract showed significantly effective than any other estract. On the inhibitory effects of Zizyphi Fructus $IL-l{\beta}$ production by monocyte, compared extracts showed 70% of highly inhibitory effect than that of 60% inhibition effects on controlled group and each extracts showed no significant difference. In $PGF_2$ production inhibitroy effect of Zizyphi Fructus gingival fibroblasts, Herbal extracts showed 70% of inhibition comparing with tat of 90.2% of controlled group, but each extracts showed similar effects excluding the $H_2O$ extracts. These results suggested that Zizyphi Fructus might be useful medicine for inhibition of inflammatory mediator including $IL-l{\beta}$ and $PGF_2$.

  • PDF

Scientific Investigation for Conservation Methodology of Bracket Mural Paintings of Daeungjeon Hall in Jikjisa Temple (직지사 대웅전 포벽화 보존방안을 위한 과학적 조사)

  • Lee, Hwa Soo;Kim, Seol Hui;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.34 no.2
    • /
    • pp.107-118
    • /
    • 2018
  • This report does studied for making the method of conserving bracket murals in Daeungjeon of Jikjisa Temple, through the scientific way. Results of evaluated the conservation status at the braket mural paintings, most serious damage is structural damage like cracks, breakage, and delamination. After optical investigation, a characteristic point wasn't found such as underdrawing or traces of a coat of paint. The ultrasonic examination speed by each wall painting was measured from about 195.8 m/s to 392.7 m/s, according to the location of the surface, and it was able to compare the surface properties according to the location. In Infrared-thermal image measurement shows that wall layer separation and paint layer delamination are closely detected, therefore it was able to judge of damage on the objective way. Material analysis revealed that the walls were made by sand and weathering soil. The wall layer combined sand with less than fine sand size by nearly 5:5, and the finishing layer was found to have mixed medium sand and fine sand at approximately 6:4 rates. However, In case of finishing layer, mixing ratios of sizes less than very fine sand were found to be significantly lower than wall. Therefore, it is estimated that the plysical damage such as the separation between the layers of the walls created in the braket mural paintings, is continuously caused by changes in the internal stresses and volume ratio caused by the density differences between the wall and the finishing layers.

Long-Period Wave Oscillations in Sokcho Harbor and Cheongcho Lagoon (1. Field Measurements and Data Analyses) (속초항과 청초호의 부진동 특성 (1. 현장관측과 자료 분석))

  • 정원무;박우선;김규한;채장원;김지희
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.1
    • /
    • pp.51-64
    • /
    • 2002
  • To investigate long-period wave responses in Sokcho Harbor and Cheongcho lagoon, field measurements were made for long-and short-period waves and current velocities using a Directional Waverider, a ultrasonic-type wave gauge, four pressure-type wave gauges, and a current meter. From the data analysis, it was found that the Helmholtz resonant periods of Sokcho Harbor and Cheongcho lagoon are about 13.6 and 54.5 minutes, respectively, and the dominant period of wave induced current in the passage between Sokcho Harbor and Cheongcho lagoon is about 55.2 minutes which depends on Helmholtz resonant condition of the Cheongcho lagoon. It was also found that the energy level of the far-infra-gravity waves during storm conditions is very high compared with that during calm sea conditions. To investigate relationships between far-infra-gravity waves and short-period waves at offshore station, regression analyses were carried out especially for 1) heights, 2) periods, 3) direction and height, 4) height and period between short-and far-infra-gravity waves, respectively. The results showed that the long-period wave height is highly correlated with the short-period wave height. However, no special trend was found for the other relations. In the future far-infra-gravity wave heights on return period around Sokcho Harbor region can be suggested by using extreme value analyses of long term measured data.

Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke (인체 요골동맥과 경동맥의 혈액에코박동지수: 나이 및 뇌졸중과의 관계)

  • Bok, Tae-Hoon;Kong, Qi;Nam, Kweon-Ho;Choi, Jay Chol;Paeng, Dong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.494-501
    • /
    • 2012
  • In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group ($0.13{\pm}0.11$ and $0.16{\pm}0.03$). PIBE of CCA for the young group, however, was larger than that for the old group ($0.70{\pm}0.21$ and $0.32{\pm}0.01$), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients ($336{\pm}61$ and $340{\pm}126mg/dl$) were more than that of the control group ($264{\pm}38$ and $257{\pm}43mg/dl$), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.