• Title/Summary/Keyword: Ultrasonic measurement

Search Result 835, Processing Time 0.021 seconds

A Study on the Fabrication and Characteristics of ITO Thin Film Deposited by Magnetron Sputtering Method (마그네트론 스퍼터링법을 이용한 Indium-Tin Oxide 박막의 제작과 그 특성에 관한 연구)

  • 조길호;김여중;김성종;문경만;이명훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.61-69
    • /
    • 2000
  • Indium-Tin Oxide (ITO) films were prepared on the commercial glass substrate by the Magnetron Sputtering method. The target was a 90wt.% $In_2O_3$-10wt.% $SnO_2$with 99.99% purity. The ITO films deposited by changing the partial pressure of oxygen gas ($O_2$/(Ar+$O_2$)) of 2, 3 and 5% as well as by changing the substrate temperature of $300^{\circ}C$ or $500^{\circ}C$. The influence of substrate pre-annealing and pre-cleaning on the quality of ITO film were examined, in which the substrate temperature was $500^{\circ}C$ and oxygen partial pressure was 3%. The characteristics of films were examined by the 4-point probe, Hall effect measurement system, SEM, AFM, Spectrophotometer, and X-ray diffraction. The optimum ITO films have been obtained when the substrate temperature is $500^{\circ}C$ and oxygen partial pressure is 3%. At optimum condition, the film showed transmittance of 81%, sheet resistivity of $226\Omegatextrm{cm}^2$, resistivity($\rho$) of $5.4\times10^{-3}\Omega$cm, carrier concentration of $1.0\times10^{19}cm^{-3}$, and carrier mobility of $150textrm{cm}^2$Vsec. From XRD spectrum, c(222) plane was dominant in the case of substrate temperature at $300^{\circ}C$, without regarding to oxygen partial pressure. However, in the case of substrate temperature at $500^{\circ}C$, c(400) plane was grown together with c(222) plane, only for oxygen partial pressure of 2 and 3%. In both case of chemical and ultrasonic cleaning without pre-annealing the substrate, it showed much almost same sheet resistivity, resistivity($\rho$), transmittance, carrier concentration, and carrier mobility. In case of $500^{\circ}C$/60min pre-annealing before ITO film deposited, both transimittance and carrier mobility are better than no pre-annealing, because pre-annealing is supposed to remove alkari ions diffusion from substrate. ITO film deposited on the Corning 0080 sybstrate showed a little bit better sheet resistivity, resistivity($\rho$), transimittance, carrier concentration than the film deposited on commercial glass. But no differences between Corning substrate and pre-annealed commercial glass substrate are found.

  • PDF

The Study on development of a SAW SO$_2$ gas sensor (표면탄성파를 이용한 아황산 가스센서 개발에 관한 연구)

  • Lee, Young-Jin;Kim, Hak-Bong;Roh, Yong-Rae;Cho, Hyun-Min;Baik, Sung;,
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 1997
  • A new type SO$_2$ gas sensor with a particular inorganic thin film on SAW devices was developed. The sensor consisted of twin SAW oscillators of the center frequency of 54 MHz fabricated on the LiTaO$_3$ piezoelectric single crystal. One delay line of the sensor was coated with a CdS thin film that selectively adsorbed and desorbed SO$_2$, while the other was uncoated for use as a stable reference. Deposition of the CdS thin film was carried out by the spray pyrolysis method using an ultrasonic nozzle. The sensor could measure the concentration in air less than 0.25 parts per million of SO$_2$. Stability of the sensor turned out to be as good as less than 20ppm, recovery time after each measurement was as short as 5 minutes. Repeatability of the measurement was confirmed through so many reiterated experiments. Hence, the SAW sensor developed through this work showed promising performance as a microsensing tool of SO$_2$. Further work required to improve the performance of the sensor includes enhancement of the reactivity of the CdS thin film with SO$_2$ through appropriate dopant addition, an increase of the center frequency of the SAW device.

  • PDF

The Design of the Obstacle Avoidances System for Unmanned Vehicle Using a Depth Camera (깊이 카메라를 이용한 무인이동체의 장애물 회피 시스템 설계)

  • Kim, Min-Joon;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.224-226
    • /
    • 2016
  • With the technical development and rapid increase of private demand, the new market for unmanned vehicle combined with the characteristics of 'unmanned automation' and 'vehicle' is rapidly growing. Even though the pilot driving is currently allowed in some countries, there is no country that has institutionalized the formal driving of self-driving cars. In case of the existing vehicles, safety incidents are frequently happening due to the frequent malfunction of the rear sensor, blind spot of the rear camera, or drivers' carelessness. Once such minor flaws are complemented, the relevant regulations for the commercialization of self-driving car and small drone could be relieved. Contrary to the ultrasonic and laser sensors used for the existing vehicles, this paper aims to attempt the distance measurement by using the depth sensor. A depth camera calculates the distance data based on the TOF method calculating the time difference by lighting laser or infrared light onto an object or area and then receiving the beam coming back. As this camera can obtain the depth data in the pixel unit of CCD camera, it can be used for collecting depth data in real-time. This paper suggests to solve problems mentioned above by using depth data in real-time and also to design the obstacle avoidance system through distance measurement.

  • PDF

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구)

  • Maeng, Myoung-Ho;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.207-220
    • /
    • 2006
  • The newly developed equipments for the early detection of carious lesion are LFD (laser fluorescence device), Ultrasonic diagnostic system, CLSM(confocal laser scanning microscopy), QLF(quantitative light-induced fluorescence) and DIFOTI (digital imaging fiber-optic trans-illumination) system. In this study, DIFOTI system and LFD were used for the detection of early enamel caries. Twenty five primary teeth extracted from twenty one children at around the dentitional exchanging period were selected as samples. The results obtained from DIFOTI imaging and LFD measurement were compared with those of CLSM and comprehensive evaluations were made for the diagnostic capacity of each device. In vitro test, 40 sample teeth with their buccal & lingual surface formed by a window of $2{\times}3mm$ in diameter were immersed in artificial demineralizing solution for the period of 4, 8, 12 and 16 days. The results obtained from the experimental groups (DIFOTI, LFD) were compared to control group (CLSM) and we have reached to the following conclusions. 1. The sensitivity and specificity of DIFOTI system operated in oral environment was 88.2% and 76.9% respectively. 2. The sensitivity and specificity of LFD measured in oral environment was 76.5% and 69.2% respectively. 3, Regression analysis on the light transparent rate of DIFOTI showed its decrease according to the length of primary enamel decalcification performed in vitro(r=-0.96, p<0.05). 4. No statistically significant difference between LFT measurement and the length of in vitro decalcification was found in regression analysis (p>0.05). 5. The correlation coefficient of DIFOTI image transparent rate and the lesion depth of CLMS was -0.6988 (p<0.05), whereas no statistically significant difference was found for LFD measurement.

  • PDF

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.

Study on Characteristic of CO2 Hydrate Formation Using Micro-sized Ice (미세직경 얼음을 이용한 CO2 하이드레이트 제조특성 연구)

  • Lee, Jong-Hyub;Kang, Seong-Pil
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.690-695
    • /
    • 2012
  • Gas hydrate is an inclusion compound consisting of water and low molecular weight gases, which are incorporated into the lattice structure of water. Owing to its promising aspect to application technologies, gas hydrate has been widely studied recently, especially $CO_2$ hydrate for the CCS (Carbon Capture and Storage) issue. The key point of $CO_2$ hydrate technology for the CCS is how to produce gas hydrate in an efficient and economic way. In this study, we have tried to study the characteristic of gas hydrate formation using micro-sized ice through an ultrasonic nozzle which generate 2.4 MHz frequency wave. $CO_2$ as a carrier gas brings micro-sized mist into low-temperature reactor, where the mist and carrier gas forms $CO_2$ hydrate under $-55^{\circ}C$ and atmospheric pressure condition and some part of the mist also remains unreacted micro-sized ice. Formed gas hydrate was average 10.7 of diameter at average. The starting ice particle was set to constant pressure to form $CO_2$ hydrate and the consumed amount of $CO_2$ gas was simultaneously measured to calculate the conversion of ice into gas hydrate. Results showed that the gas hydrate formation was highly suitable because of its extremely high gas-solid contact area, and the formation rate was also very high. Self-preservation effect of $CO_2$ hydrate was confirmed by the measurement of $CO_2$ hydrate powder at normal and at pressed state, which resulted that this kind of gas storage and transport could be feasible using $CO_2$ hydrate formation.

Fabrication of a PMN-PZT needle hydrophone for photoacoustic imaging (광음향 영상화를 위한 PMN-PZT 바늘형 수중청음기 제작)

  • Fan, Xiaofeng;Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kang, Hyun Wook;Oh, Junghwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2016
  • For application to several MHz photoacoustic imaging systems, a needle hydrophone was designed and fabricated by using PMN-PZT piezoelectric single crystal, and its characteristics were evaluated through comparison with a commercial PVDF(Polybinylidene Fluoride) hydrophone of which receiving sensitivity is known. The simulation using the KLM model results show that the peak receiving impulse response for $50{\Omega}$ terminating impedance of the fabricated hydrophone is -261.6 dB re $1V/{\mu}Pa$ and the frequency response is relatively flat over 2 ~ 12 MHz with fluctuation less than 5 dB. The measurement results using tone burst signals also show that it has higher (ave. 10.9 dB) sensitivity than the commercial hydrophone in 2 ~ 8 MHz, and the receiving sensitivity of $-255.8{\pm}2.8$ dB re $1V/{\mu}Pa$ was measured for the fabricated hydrophone. In addition, it is known that the photoacoustic signals and the image of a hair obtained by a mechanical scanned photoacoustic imaging system with the fabricated hydrophone were bigger and better than those obtained with the commercial hydrophone.

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Models for Hydration Heat Development and Mechanical Properties of Ultra High Performance Concrete (초고성능 콘크리트의 수화발열 및 역학적 특성 모델)

  • Cha, Soo-Won;Kim, Ki-Hyun;Kim, Sung-Wook;Park, Jung-Jun;Bae, Sung-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.389-397
    • /
    • 2010
  • Concrete has excellent mechanical properties, high durability, and economical advantages over other construction materials. Nevertheless, it is not an easy task to apply concrete to long span bridges. That's because concrete has a low strength to weight ratio. Ultra high performance concrete (UHPC) has a very high strength and hence it allows use of relatively small section for the same design load. Thus UHPC is a promising material to be utilized in the construction of long span bridges. However, there is a possibility of crack generation during the curing process due to the high binder ratio of UHPC and a consequent large amount of hydration heat. In this study, adiabatic temperature rise and mechanical properties were modeled for the stress analysis due to hydration heat. Adiabatic temperature rise curve of UHPC was modeled superposing 2-parameter model and S-shaped function, and the Arrhenius constant was determined using the concept of equivalent time. The results are verified by the mock-up test measuring the temperature development due to the hydration of UHPC. In addition, models for mechanical properties such as elastic modulus, tensile strength and compressive strength were developed based on the test results from conventional load test and ultrasonic pulse velocity measurement.