Microstructure and Piezoelectric Properties of PMN-PNN-PZT Ceramics (PMN-PNN-PZT 세라믹스의 미세구조 및 압전 특성)

  • Yoo, Ju-Hyun;Kim, Seung-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.8
    • /
    • pp.496-500
    • /
    • 2017
  • $Pb(Mn_{1/3}Nb_{2/3})_{0.07}(Ni_{1/3}Nb_{2/3})_{0.10}(Zr_{0.5}Ti_{0.5})_{0.83}O_3$ composition ceramics with high piezoelectric properties were fabricated by the columbite precursor method for ultrasonic generators, and the effects of sintering temperature on microstructure and piezoelectric properties were systematically investigated. It was found that the tetragonality of the ceramics decreased with increase in sintering temperature. Moreover, excellent physical properties such as $d_{33}=447pC/N$, ${\varepsilon}_r=1,843$, $k_p=0.641$, and $Q_m=1,207$ were obtained for an ultrasonic generator when the second calcination temperature and sintering temperature were $720^{\circ}C$ and $920^{\circ}C$, respectively.

Research for Signal Analysis of 18Mn-5Cr Steel Generator Retaining Ring using Ultrasonic Wave (초음파를 이용한 18Mn-5Cr강 발전기 리테이닝 링의 신호분석에 관한 연구)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.65-70
    • /
    • 2010
  • Retaining rings are used to support the field winding end turns from the centrifugal force by the high speed of the field and these are the overstressed parts among the generator parts. There have been several retaining failures in Europe and America, all attributable to stress corrosion cracking in 18Mn-5Cr steel. Since then, each manufacture companies have developed a good 18Mn-5Cr steel in temperature, strength characteristic and it is used in many field now. From many findings and test results, we could conformed that the failure might be grown in the overstressed condition unrelated to the moisture particle.

A Study on the Performance of Diesel Automobile of Ultrasonic Fuel Supply System(I) -About the Droplet Size Distribution of Ultrasonic Fuel Supply System - (초음파(超音波) 연료공급장치용(燃料供給裝置用) 디젤자동차(自動車)의 성능(性能) 향상(向上) 관한 연구(I) -초음파 연료공급장치를 통과한 연료의 분무특성에 대하여-)

  • Choi, D.S.;Seol, J.H.;Ryu, J.I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • This study carried out to investigate the spray characteristics of diesel oil through out ultrasonic fuel supply system in comparison with conventional. Size of the droplets comprising diesel spray was measured by immersed liquid method at different positions along the spray axis. Droplets distribution diagram was ploted and Sauter Mean Diameter(SMD) was also calculated. The effects of the ultrasonic vibration and injection pressure on the droplet size distribution and SMD were investigated. As the ultrasonic vibration supply SMD decreases on the same injection pressure conditions with conventional injector's. But the effect of ultrasonic vibration decreases with injection pressure increasing.

  • PDF

A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants (원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구)

  • Yu Sung-Sik;Park Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.

Improved Ultrasonic Method for Locating Partial Discharges in Transformers (개선된 초음파방법에 의한 변압기내 부분방전 위치 검출)

  • Kwak, Hee-Ro;Kim, Jae-Chul;Cho, Kook-Hee;Han, Min-Koo;Lim, Ju-Il;Kwan, Tae-Won;Yoon, Young-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.252-257
    • /
    • 1988
  • This paper discribes an improved technique for locating partial discharge sites within operating transformers by ultrasonic method which utilizes the different travel times of the electrical and ultrasonic signals produced by partial discharges to determine the location of the sources. The technique was to develope the measurement system based on the enhancement of the acoustic emission signals using signal square, circuit to improve the detectable sensitivity and reliability. Also an ultrasonic pulse generator was designed and made to transmit periodically pulses equivalent to pratial discharges and to check the good performance of the system, echo effects and self-diagnosis. Through the laboratory work, it was confirmed that the system and the generator can be used satisfactorily for diagnosing power transformers and for studying echo effects and self-diagnosis of the system.

  • PDF

Ultrasonic Speckle Surpression Technique for Nondestructive Evaluation of Steam Generator in Nuclear Power plants (핵발전소의 증기발생기 비파괴 평가를 위한 초음파 스펙클 감소 기술)

  • Lee Youngseock;CHO Hyunseob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.151-154
    • /
    • 2005
  • In this paper, we present a ultrasonic speckle suppression method for centrifugal-casted stainless steel sample by computer simulations of a flaw enhancement algorithm. Because of their practical importance in welds, the ultrasonic signal obtained from heat-affected zone or welds are investigated for computer simulation. The results for computer simulation present the more enhanced flaw-visibility and speckle suppression than the compared two techniques.

  • PDF

Selective Activation for Global Ultrasonic System (전역 초음파 시스템의 선택적 활성화)

  • Kim Jin-Won;Kim Yong-Tae;Hwang Samuel B.;Yi Soo-Yeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.955-961
    • /
    • 2006
  • The global ultrasonic system for the self-localization of a mobile robot consists of several ultrasonic transmitters fixed at some reference positions in the global coordinates of robot environment. By activating the ultrasonic transmitters, the mobile robot is able to get the distance to the ultrasonic transmitters and compute its own position in the global coordinate. Due to the limitation on the ultrasonic signal strength and beam width as well as the environmental obstacles however, the ultrasonic signals from some generator may not be transmitted to the robot. Thus, instead of activating the all ultrasonic transmitters, it is necessary to select some ultrasonic generators to activate based on the current robot position. In this paper, we propose a selective activation algorithm for self-localization with the global ultrasonic system. The selective activation algorithm gets the meaningful ultrasonic data at every sampling instants, which results in the faster and more accurate response of the self-localization than the conventional sequential activation. Through the self-localization and path following control, we verify the effectiveness of the proposed selective activation algorithm.

Experimental Study on CHF Enhancement of Plate by Ultrasonic (초음파에 의한 평판에서의 임계열유속 증진에 대한 실험적 연구)

  • Kim, Dae-Hun;Kweon, Young-Chel;Jeong, Ji-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1512-1517
    • /
    • 2003
  • Augmentation of CHF by ultrasonic is experimentally studied under subcooling pool boiling condition. Experiment is carried out for downward-facing plate with and without the ultrasonic. The working fluid is distilled water. Experimental apparatus is composed of a bath, power supply, test section, ultrasonic generator, DAQ system. Experiment is performed with the subcooling temperature of $5^{\circ}C$, $20^{\circ}C$, $40^{\circ}C$ and the inclined angle of $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $45^{\circ}$, 90. From the experimental results, it is found that ultrasonic effect enhances CHF of the downward-facing plate. As increasing the degree of subcooling, the rate of CHF increase is enhanced. As increasing the inclined angle, the rate of CHF increase decreases. Also, we can see that the heat transfer mechanism of CHF augmentation is closely connected with the dynamic behavior of bubble generation and departure.

  • PDF