• 제목/요약/키워드: Ultrasonic dependence

검색결과 54건 처리시간 0.036초

A novel method for discriminating between water and oil using the temperature dependence of ultrasonic travel time

  • Katsunori, Shida;Toyonori, Matsuda
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.86.6-86
    • /
    • 2001
  • For discriminating between water and oil, a novel method is proposed in this paper. As a fundamental result, the temperature dependence of ultrasonic travel time of water and oil measured from 5$^{\circ}C$ to 40$^{\circ}C$ at a step of 5$^{\circ}C$ is found as that the ultrasonic travel time of oil increases with increasing temperature, whereas that of water decreases. The proposed method for discriminating between water and oil is based on the opposite temperature dependence of ultrasonic travel time of water and oil. Besides the advantages of non-invasion and on-line measurement, there are no requirements of measuring the temperature of liquid being detected and obtaining previously a large quantity of database, and furthermore, only two times of measurements are ...

  • PDF

PVDF 초음파 변환기의 제작과 특성에 관한 연구 (A Study on Fabrication and Characteristics of PVDF Ultrasonic Transducer)

  • 정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.33-37
    • /
    • 2000
  • The authors fabricated ultrasonic transducer with PVDF[poly(vinylidene fluoride)] piezoelectric polymer film. When impulse waves were applied to the PVDF ultrasonic transducer, the dependence of the response properties on the backing material with copper was investigated through not only theoretical calculations using Mason's equivalent circuit but also experimental measurements. The experimental pulse response properties agree with those of the theoretical calculations and the pulses were shorter than those for a PZT transducer. If such short-pulse properties are used in an medical ultrasonic image diagnosis apparatus, the resolution of the apparatus will be improved. When the insertion loss was calculated theoretically to the PVDF ultrasonic transducer, the frequency characteristics of its showed wideband frequency.

  • PDF

SCM440 강의 결정입도와 조직의 변화에 따른 초음파 감쇄 (Ultrasonic Attenuation due to the Changes of Grain Size and microstructure of SCM440 Steel)

  • 박은수;강계명;김선진;장순식
    • 한국재료학회지
    • /
    • 제3권6호
    • /
    • pp.585-592
    • /
    • 1993
  • 여러 온도에서 급냉 및 템퍼링시킨 SCM440강을 이용하여 결정입도와 조직의 변화가 초음파감쇄에 미치는 영향에 관하여 연구하였다. 초음파감쇄는 주로 결정립에 의한 산란에 기인하였으며 감쇄계수는 결정립의 크기가 클수록 증가하였으나 템퍼링 시킨 조직의 경우 템퍼링온도가 높아질수록 감쇄계수는 감소하는 것을 알 수 있었다. 주파수의 의존성은 직선적인 log-log 관계를 가지며 Roney의 식과 비례하는 것으로 조사되었다.

  • PDF

Ultrasonic Speed and Isentropic Compressibility of 2-propanol with Hydrocarbons at 298.15 and 308.15 K

  • Gahlyan, Suman;Verma, Sweety;Rani, Manju;Maken, Sanjeev
    • Korean Chemical Engineering Research
    • /
    • 제55권5호
    • /
    • pp.668-678
    • /
    • 2017
  • Intermolecular interactions were studied for binary mixtures of 2-propanol + cyclohexane, n-hexane, benzene, toluene, o-, m- and p-xylenes by measuring ultrasonic speeds (u) over the entire range of composition at 298.15 K and 308.15 K. From these results the deviation in ultrasonic speed was calculated. These results were fitted to the Redlich-Kister equation to derive the binary coefficients along with standard deviations between the experimental and calculated data. Acoustic parameters such as excess isentropic compressibility ($K_s^E$), intermolecular free length ($L_f$) and available volume ($V_a$) were also derived from ultrasonic speed data and Jacobson's free length theory. The ultrasonic speed data were correlated by Nomoto's relation, Van Dael's mixing relation, impedance dependence relation, and Schaaff's collision factor theory. Van Dael's relation gives the best prediction of u in the binary mixtures containing aliphatic hydrocarbons. The ultrasonic speed data and isentropic compressibility were further analyzed in terms of Jacobson's free length theory.

초음파를 이용한 공석강의 펄라이트 층상간격 평가 (Ultrasonic Evaluation of Pearlite Interlamellar Spacing in Eutectoid Steel)

  • 김준수;변재원;권숙인;이승석;안봉영
    • 열처리공학회지
    • /
    • 제14권1호
    • /
    • pp.22-26
    • /
    • 2001
  • The microstructural changes with pearlite formation heat treatment in eutectoid steel(railway steel) consisting of only pearlite structure were evaluated by the ultrasonic attenuation and velocity measurements. The result of this investigation showed a strong linear dependence of ultrasonic attenuation on pearlite interlamellar spacing, and accordingly on fracture strength of the pearlite.

  • PDF

초음파의 감쇠를 이용한 복합재료의 기공함량 평가 (Void Contents Evaluation of Composite Laminates by Ultrasonic Attenuation Measurements)

  • 정현조
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1535-1541
    • /
    • 1994
  • The void content of carbon fiber reinforced composite laminates was determined by the ultrasonic nondestructive technique. The ultrasonic immersion, through-transmission method developed stresses the utilization of spectral analysis and frequency dependence of the attenuation due to porosity. The measured attenuation shows approximately linear behavior over the frequency range investigated. The linear relationship between the void content and the attenuation slop (d $\alpha$/df) is found to hold, but the constant of proportionality is quite different for samples with different pore morphology. The void volume fraction determined by the attenuation slope agreed very well with that obtained by the acid digestion analysis.

란쥬반형진동자에 관한 연구 (A study on the langevin type vibrators)

  • 박정엽;한득영;박태곤
    • 전기의세계
    • /
    • 제30권1호
    • /
    • pp.47-54
    • /
    • 1981
  • The fabrication of Langevin type vibrators producing relatively high sonic and ultrasonic energy is described. The dependence of the acoustic output and the frequency characteristics on the thickness of the steel plates and the pressure at the ceramics are investigated. As results, the acoustic output of Langevin type vibrators are relatively high, and the resonant frequency is decreassed by thickening the steel plates and lowering the pressure at the ceramics. Using these results, sonic and ultrasonic vibrator whose resonant frequency is determined can be designed.

  • PDF

상용 MC Nylon계 고분자 재료에서 초음파 특성의 온도 및 주파수 의존성 (Temperature and Frequency Dependences of Ultrasonic Properties in Commercial MC Nylon Polymers)

  • 김명덕;김용태;이강일
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.509-517
    • /
    • 2012
  • 본 연구에서는 상용화된 monomer-cast nylon (MC nylon)계 고분자 재료로 만든 6종류의 시편에 대하여 감쇠계수 및 위상속도와 같은 초음파 특성의 온도 및 주파수 의존성을 조사하였다. 시편의 초음파 특성은 수중에서 2 MHz부터 8 MHz까지의 광대역 주파수 범위에 대하여 펄스투과법을 이용하여 측정하였다. 수온은 $10^{\circ}C$부터 $60^{\circ}C$까지 $10^{\circ}C$ 간격으로 변화시켰다. 측정에 사용된 모든 시편에서 감쇠계수는 주파수가 증가함에 따라 증가하였으며, 주파수의 지수 의존성 n이 선형 (n=1)에서 약간 벗어난 1.16부터 1.44이내의 값을 가졌다. 위상속도는 $60^{\circ}C$에서 ivory 시편을 제외한 모든 경우에 대하여 주파수가 증가함에 따라 감소하는 음의 분산 특성을 나타냈다. 주파수에 의존하는 위상속도는 모든 시편에서 온도가 증가함에 따라 감소하는 특성을 나타내었다.

Ultrasonic Velocity and Absorption Measurements in an Aqueous Solution of Poly(sodium 4-styrenesulfonate)

  • Rae Jong-Rim
    • Macromolecular Research
    • /
    • 제12권6호
    • /
    • pp.559-563
    • /
    • 2004
  • Both the ultrasonic velocity at 3 MHz and the absorption coefficient in the frequency range from 0.2 to 2 MHz were measured for aqueous solutions of poly(sodium 4-styrenesulfonate) over the concentration range from 5 to $25\%$ (by weight). The pulse echo overlap method was employed to measure the ultrasonic velocity over the temperature range from 10 to $90^{\circ}C;$ the high-Q ultrasonic resonator method was used for the measurement of the absorption coefficient at $20^{\circ}C.$ The velocities exhibited their maximum values at ca. 55, 59, 63, 67, and $71^{\circ}C.$ for the 25, 20, 15, 10, and $5\%$ solutions, respectively. The velocity increased with respect to the poly(sodium 4-styrene-sulfonate) concentration at a given temperature. A study of the concentration dependence of the both the relaxation frequency and amplitude indicated that the relaxation at ca. 200 kHz is related to structural fluctuations of the polymer molecules, such as the segmental motions of the polymer chains and that the relaxation at ca. 1 MHz resulted from the proton transfer reactions of the oxygen sites of $SO_3.$ Both the absorption and the shear viscosity increase upon increasing the polymer concentration, but they decrease upon increasing the temperature.

지방질에 대한 초음파 비선형 파라메타 B/A의 의존성 (Dependence of Ultrasonic Nonlinear Parameter B/A on Fat)

  • 김정구;배종림
    • 한국음향학회지
    • /
    • 제19권4호
    • /
    • pp.101-106
    • /
    • 2000
  • 광대역 고분자 초음파 변환기를 이용한 초음파 비선형 파라메타 B/A 측정장치를 이용하여 생체조직에서 지방질의 농도에 대한 B/A의 의존성을 알아보기 위하여 계란의 흰자와 노른자의 혼합에 대하여 조사하였다. 이들 두 성분에 대한 음속과 밀도가 서로 1% 정도임에도 불구하고 yoshizuni등에 의해 제시된 선형성보다 이차적 의존성이 더 있음을 확인하였다. 이것은 생체조직을 fat과 nonfat의 두 부분으로 나누어 지방질의 농도에 대한 초음파 비선형 파라메타 B/A와 음속의 크기에 대하여 본 연구에서 제시한 이론식과 잘 일치하였다. 또한 지방질이 없는 skim milk의 다양한 용해도 성분에 대한 B/A와 음속을 측정한 결과 용해도의 농도가 클수록 B/A와 음속의 값이 커짐을 알 수 있었으며, 이들에 영향을 주는 것은 단백질 등으로 예상된다.

  • PDF