• Title/Summary/Keyword: Ultrasonic cutting

Search Result 84, Processing Time 0.023 seconds

Detection of Tool Wear by Using the Ultrasonic In-Process Sensor (초음파 인프로세스 센서를 이용한 공구마멸 검출)

  • Kang, H.S.;Hwang, J.;Ko, B.J.;Chung, E.S.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.3
    • /
    • pp.55-60
    • /
    • 2001
  • A technique on the detection of tool wear based on the ultrasonic pulse-echo method in turning process is presented. The change in amount of the reflected energy from nose and flank of the tool can be related to the level of tool wear and mechanical integrity of the tool, that is, there exists an excellent correlation between the ultrasonic measurement and tool wear. As a results, the method is very useful for the prediction of cutting tool life and the determination of tool exchange period.

  • PDF

Prediction of Fracture Appearance Transition Temperature(FATT) to Steel by Ultrasonic and Barkhausen Noise Method (초음파와 Barkhausen Noise에 의한 강의 연.취성천이온도 예측)

  • Nam, Young-Hyun;Seong, Un-Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1215-1222
    • /
    • 1999
  • It is advantageous to use an NDE method to assess the mechanical properties of materials since the conventional method is time-consuming and sometimes requires cutting of sample from the material/component. This paper shows that the ultrasonic and the Barkhausen noise(BHN) methods can be used to accurately characterize forged reactor vessels. The attenuation coefficient of the ultrasonic wave was changed with heat treatment temperature and condition[as-quenched, tempered, PWHT]. The RMS[root mean square] voltage of Barkhausen noise depended on heat treatment temperature and conditions. The fracture appearance transition temperature(FATT) can be predicted using nondestructive evaluation methods.

A Study on the Design of Tool Horn for Cutting Converged with Theoretical Method and FEA (이론적 방법과 유한요소해석이 융합된 커팅용 공구 혼의 설계에 관한 연구)

  • Lee, Han-Chang;Jeong, Jin-Hyuk;Park, Chung-Woo;Oh, Myung-Seok;Park, Myung-Kyu;Lee, Bong-Gu;Kim, Chang-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.175-182
    • /
    • 2018
  • In this study, the theoretical method and the finite element analysis were designed in parallel to fabricate basic research data on the production of tool horn for cutting machine with ultrasonic vibration energy. In order to perform high-performance ultrasonic cutting, it is necessary to vibrate only with longitudinal vibration instead of transverse vibration. In order to efficiently transmit the mechanical vibration energy, the maximum amplitude should be generated at the output portion. Therefore, the tool horn must be designed so that the excitation frequency of the oscillator and the natural frequency of the tool horn are the same. In order to design the resonance of the tool horn, there are a theoretical approach using the one-dimensional wave equation and a method of reflecting the finite element analysis result to the design model. In this study, the approximate dimensions of the tool horn are first determined through the one- Based on the results of the finite element analysis, the optimal model was selected and reflected in the final shape of the tool horn. We will use this information as the basic data of actual tool horn for cutting, and will compare the production and experimental data with the contents of this research.

A Study on the Ultrasonic Micro-machining and Measurement System (초음파 초정밀 가공 및 측정시스템에 대한 연구)

  • Ju, Jong-Nam;Han, Dong-Cheol;Park, Hui-Jae;Park, Sang-Sin;Je, Seong-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.133-140
    • /
    • 2002
  • Ultrasonic Machining (USM) is widely used in cutting of non-conductive, brittle workpiece materials such as engineering ceramics. However, USM has a limitation in its application to micro machining because problems are occurred in attaching micro tools to the machine and maintaining high precision. Therefore Micro Ultrasonic Machining (MUSM) with WEDM is proposed in this research. The experiments are produced as the change of shaft diameter and abrasive size.

EFFICIENCY OF DENTIN CUTTING AND ROOT -END RETROCAVITY PREPARATION USING ULTRASONIC DIAMOND INSTRUMENTS AND THEIR INFLUENCE ON TOOTH STRUCTURE (초음파 다이아몬드 기구의 상아질 삭제 효과, 치근단 역충전 와동 형성효율 및 치질에의 영향)

  • Lim, Choon-Hee;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.54-67
    • /
    • 1998
  • The purposes of this study were to evaluate the efficiency of dentin cutting and root-end cavity preparation, and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with. ultrasonic diamond instruments. To evaluate the efficiency of dentin cutting, ultrasonic diamond and stainless steel instruments were applied to 20 exposed bovine dentin surfaces perpendicularly or parallely at the low, and medium power settings for 1 minute ($Miniendo^{TM}$, EIE, CA, U.S.A.). The resultant cavity depth was measured. To evaluate the efficiency of cavity preparation and to investigate the incidence of tooth crack, 165 mesiobuccal, distobuccal and palatal root-ends of extracted human maxillary first molars were resected by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw after root canal preparation and filling. Retrocavities were prepared using a ultrasonic diamond instrument or a stainless steel one of the low- or medium power settings of 2 or 6. Time consumed and the number of strokes used for the cavity preparation were measured and the incidence of tooth cracks was evaluated under a stereomicroscope. The results were as follows: Both at the low and medium power settings, and both with perpendicularly- and parallely applied tips to dentin, diamond instruments showed higher dentin cutting efficiency than stainless steel ones did (p<0.01). When tips were applied to dentin perpendicularly, both diamond instrument and stainless steel one showed higher cutting efficiency with medium power setting than with low power one (p<0.01). Both at the low- and medium power settings, both diamond instrument and stainless steel one showed higher cutting efficiency when tips were applied perpendicularly to dentin surface than applied parallely (p<0.01). At the medium power setting, the number of stroke and time consumed were less with diamond instrument than with stainless steel one (p<0.05) for the retrograde cavity preparation. At the low power setting, diamond instrument induced less tooth cracks than stainless steel one did (p<0.01).

  • PDF

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

Heat transfer analysis of CFD at the Ultrasonic horn bonding flip chip (플립칩 접합용 초음파 혼의 CFD 열유동 해석)

  • Shim, Hyun-Sik;Rhee, Gwang-Huun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2750-2753
    • /
    • 2008
  • This paper introduce the CFD analysis for predicting the heat transfer at the Ultrasonic horn. Approximately Ultrasonic horn separates two part. One is preheating part and the other is cooling part. Temperature of preheating part rise up by $260^{\circ}C$ that make it possible to attach a chip to a semiconductor. Also there is a piezo material in the cooling part. When piezo work, it generates heat of $100^{\circ}C$. It can stand by $150^{\circ}C$. But the high temperature conducted from the preheating part has a bad affect on the piezo. These situation make it necessary cooling at piezo. Previously except of the piezo, all of them are composed of the SUS440c that has good thermal conductivity. This study shows way that not only cooling the piezo but also cutting off the conduction between preheating part and cooling part by using the Ti and Duralumin that have low thermal conductivity compare with the SUS440c. Conclusion of CFD analysis that the heat coming from the piezo can't be transferred the horn cause of the Ti and Duralumin.

  • PDF

Characteristics of Pulse Width Modulation(PWM) Excitation of Ultrasonic Elliptical Vibration Cutting Device (초음파 진동절삭기의 펄스폭변조 가진 특성)

  • Loh, Byoung Gook;Kim, Gi Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.59-65
    • /
    • 2014
  • To obtain an elliptical trajectory at the cutting edge during elliptical vibration cutting, sinusoidal voltage excitations of two piezoelectric actuators have commonly been used. In this study, PWM excitation, which is relatively simple to generate, was employed and its characteristics were investigated. In experimental and analytical analyses, we found that for PWM excitation, the integer-multiple frequencies of the excitation voltage distorted the shape of the elliptical trajectory, whereas at a duty ratio(DR) of 50%, the distortion of the elliptical trajectory was minimized due to disappearance of the first overtone. When the magnitude of the maximum excitation voltage was maintained at the same level for both PWM and sinusoidal excitation, PWM (DR=50%) excitation produced a greater vibration amplitude than sinusoidal excitation but resulted in more rapid saturation of a high-frequency power amplifier.

Experimental Evaluation of the Performance and Stability of an Ultrasonic Scaler for Dental Treatment (치과 치료용 초음파 스케일러의 성능 및 안정성에 대한 실험 평가)

  • Sa, Min-Woo;Ko, Tae-Jo;Jeon, Geum-sang;Lee, Jong-Min;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • The use of ultrasonic surgery units and scalers are steadily increasing in the field of dentistry. Such units and scalers should be evaluated before they are commercialized because the mechanical performance and stability of equipment is crucial for patients. Hence, we created a hand-piece moving system that can test bone cutting and teeth scaling. The purpose of this study was to evaluate the teeth scaling performance of ultrasonic scaler unit. Additionally, we measured the temperature distribution and noise during the test. through an experimental test, we found that a high output of an Ultrasonic NX device can cause serious damage to the teeth surface, and it was not within range in heat generation distribution and noise test.

Non-Destructive Testing of Damaged Thermoplastic Pipes Electrofusion Joints Using Phased Array Ultrasonic (위상배열초음파를 이용한 손상된 열가소성 플라스틱배관 전기융착부 비파괴검사)

  • Kil, Seong-Hee;Kim, Byung-Duk;Kwon, Jeong-Rock;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.64-68
    • /
    • 2013
  • Non destructive testing(NDT) methods of electrofusion(EF) joints of thermoplastics pipes are required for fusion joint safety and for the long term reliability of a pipe system. Electrofusion joints, which are joined at the proper fusion process and procedures, may encounter defects due to the difference of ovality between pipes and coupling, improper fusion process or porosity result from electrofusion joining. These defects can cause the failure of pipeline and by extension, they can be caused the limit to expand the use of plastics pipes. This paper studies inspection results using ultrasonic imaging method for damaged polyethylene electrofusion joints. Gas was leaking from 250mm diameter polyethylene electrofusion joints at February 2004 which was electrofused at December 1994 and operation pressure was 2.45kPa. First, surface inspection was conducted and then in order to find the types of defects examination using ultrasonic imaging method was performed. Lack of fusion and inappropriate inserting for polyethylene pipes into electrofusion coupling were found and causes of the gas leak were judged that misalignment and insert defect. Cutting inspection was performed and each inspection results were compared to. Results of ultrasonic imaging method and cutting inspection were the same.