• Title/Summary/Keyword: Ultrasonic Wave Sensor

Search Result 93, Processing Time 0.027 seconds

Characteristics of Magnetostrictive Sensor for Detecting the Flaws in Pipe (배관결함 검출을 위한 자왜형 초음파 센서의 특성)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.46-53
    • /
    • 2000
  • Magnetostrictive sensors which can be used effectively to detect flaws in pipe were fabricated. The optimal conditions to obtain the maximum generation efficiency of the ultrasonic wave were established. In case of the used steel pipe the optimal magnetic field was $250{\sim}350Oe$ and the coil width of 15mm showed the best efficiency for generating a wave with the frequency of 180 kHz. In the best condition, the wave can propagate further than 50m without serious attenuation. The amplitude of the ultrasonic wave reflected from artificial flaw had a good linear relationship to the cross-sectional area of the flaw.

  • PDF

Simultaneous active strain and ultrasonic measurement using fiber acoustic wave piezoelectric transducers

  • Lee, J.R.;Park, C.Y.;Kong, C.W.
    • Smart Structures and Systems
    • /
    • v.11 no.2
    • /
    • pp.185-197
    • /
    • 2013
  • We developed a simultaneous strain measurement and damage detection technique using a pair of surface-mounted piezoelectric transducers and a fiber connecting them. This is a novel sensor configuration of the fiber acoustic wave (FAW) piezoelectric transducer. In this study, lead-zirconate-titanate (PZT) transducers are installed conventionally on a plate's surface, which is a technique used in many structural health monitoring studies. However, our PZTs are also connected with an optical fiber. A FAW and Lamb wave are simultaneously guided in the optical fiber and the structure, respectively. The dependency of the time-of-flight of the FAW on the applied strain is quantified for strain sensing. In our experimental results, the FAW exhibited excellent linear behavior and no hysteresis with respect to the change in strain. On the other hand, the well-known damage detection function of the surface-mounted PZT transducers was still available by monitoring the waveform change in the conventional Lamb wave ultrasonic path.

Measurement of plastic anisotropy of cold rolled steel sheets using electromagnetic acoustic transducer (EMAT를 이용한 냉연강판의 소성이방성 측정)

  • 황의찬;장경영;안봉영;이승석;김수광;김상영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.383-388
    • /
    • 1994
  • Ultrasonic sensor for evaluating plastic anisotropy was developed. Magnetostrictive type EMAT is sensor to transmit and receive the Lamb wave using magnetostriction. It is suitable for on line processing because of transmitting and receiving ultrasonic without contact ODCs(orientation distribution coefficients), W $_{400}$. W $_{420}$. W $_{440}$. were respectively calculated using zeroth order Lamb wave velocities, the calculated ODCs was used for evaluating plastic anisotropy, the results was compared for mean values of destructive tests. Besides, the Lorentz EMAT for generating longitudinal wave and two shear waves simultaneously and the Lorentz type EMAT for measuring SH wave velocities were made. ODCs were calculated using the measured resonant modes and velocities. the results of two methods show possibility of an line processing measurement.

  • PDF

Design and Fabrication of Magnetostrictive Transducers for Scanning OPMT Development (주사형 OPMT 개발을 위한 자왜형 초음파 변환기 설계 및 제작)

  • Lee, Ho-Cheol;Kim, Hyeng-Yoon;Kim, Y.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.856-859
    • /
    • 2005
  • The OPMT(Orientation-adjustable Patch-type Magnetostrictive Transducer) was proposed as a tool for generating and measuring the ultrasonic Lamb wave in plate type structures. This sensor has a lot of new features compared to the traditional piezo-type ultrasonic transducers. As an example, it does not need any kind of wiring for lunching or measuring ultrasonic waves. But it has also definite limitation for practical usage as a nondestructive testing tool in that it cannot help rotating the direction of ultrasonic wave manually. The idea for 'scanning OPMT' is proposed in this respect. Two kinds of basic ideas for rotating the wave direction not manually but electrically are proposed. The fabrication of the transducer and the testing for Identifying the primary characteristics are done for one of the proposed transducers. The results says that there are the possibilities as a new tool for NDE in that the proposed transducer follows well the characteristics of the traditional OPMT. But there are also the 1imitations to overcome.

  • PDF

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

Feasibility Study on Ultrasonic Waveguide Sensor for Under-Sodium Viewing of Reactor Internals in Sodium-Cooled Fast Reactor (소듐냉각고속로 원자로 내부구조물의 소듐내부가시화를 위한 웨이브가이드 초음파센서의 적용 가능성 연구)

  • Joo, Young-Sang;Lim, Sa-Hoe;Park, Chang-Gyu;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.364-371
    • /
    • 2008
  • Ultrasonic waveguide sensor has been developed for under-sodium viewing of reactor internal structures of a sodium-cooled fast reactor (SFR). The structure design concept of a waveguide sensor assembly was suggested and evaluated for the application in SFR. A 10 m long ultrasonic waveguide sensor assembly has been manufactured and the experimental feasibility tests were carried out. The 10 m long distance propagation performance of zero-order antisymmetric $A_0$ Lamb wave has been verified. The feasibility of ultrasonic waveguide sensor has been demonstrated by the C-scanning resolution performance test.

Surface Flatness Improvement in Si Anisotropy Etching Process Utilizing Ultrasonic Wave Technology (초음파 기술을 이용한 실리콘 이방성 식각 공정에서의 표면 평탄화 향상 연구)

  • Yun, Eui-Jung;Kim, Jwa-Yeon;Lee, Kang-Won;Lee, Seok-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.416-417
    • /
    • 2005
  • In this study, we optimized the process of Si anisotropy etching by combing tetramethyl ammonium hydroxide (TMAH) etching process with ultrasonic wave technology. New ultrasonic TMAH etching apparatus was developed and it was used for fabricating a $20{\mu}m$ thick diaphragm for Si piezoresistive pressure sensors. Based on comparison study on etch rate and surface flatness, it was observed that the Si anisotropy etching methode with new ultrasonic TMAH etching apparatus (at 40 kHz/ 500 watt) was superior to conventional etching methods with TMAH or TMAH+ammonium persulfate(AP) solutions.

  • PDF

Characteristics and Signal Analysis of Fiber-optic Sensor for Detecting Ultrasonic Waves Generated by Discharge in Insulation Oil (유중 방전에 의한 초음파 측정용 광섬유 센서 특성 및 측정 데이터 분석)

  • 이상훈;송현직;이광식;김달우
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.481-486
    • /
    • 2003
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

A Basic Study on the Water Level Limit Sensor Utilizing Acoustic Impedance Matching (음향임피던스 정합을 이용한 액면레벨 리미트 센서의 기초연구)

  • Kim, Cheol-Han;Lee, Su-Ho;SaGong, Geon;Lee, Jun-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.352-353
    • /
    • 2005
  • In this paper, an ultrasonic level limit sensor with a new structure utilizing the acoustic impedance matching is proposed to be able to check it out a change of water-level. 2 PZT resonators with the same property are bonded directly on the polyethylene plate. One is for transmitter as an ultrasonic transducer, the other one is for receiver. In this case, a polyethylene plate will operate as an acoustic guider to transmit a transverse wave between 2 PZT resonators in air. While in the water, a polyethylene plate having a similar acoustic impedance with the water will be emitted an acoustic energy into the water as a longitudinal wave. According to this mechanism, there was a wide difference of acoustic signal output between underwater and in air. As a summary, it is believed that this proposed level limit sensor could be used as a new one with strong toughness from the external electrical and mechanical noise.

  • PDF

Sensing properties of optical fiber sensor to ultrasonic guided waves

  • Zhou, Wensong;Li, Hui;Dong, Yongkang;Wang, Anbang
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.471-484
    • /
    • 2016
  • Optical fiber sensors have been proven that they have the potential to detect high-frequency ultrasonic signals, in structural health monitoring field which generally refers to acoustic emission signals from active structural damages and guided waves excited by ultrasonic actuators and propagating in waveguide. In this work, the sensing properties of optical fiber sensors based on Mach-Zehnder interferometer were investigated in the metal plate. Analytical formulas were conducted first to explore the parameters affecting its sensing performances. Due to the simple and definable frequency component, the Lamb wave excited by the piezoelectric wafer was employed to study the sensitivity of the proposed optical fiber sensors with respect to the frequency, rather than the acoustic emission signals. In the experiments, according to above investigations, spiral shape optical fiber sensors with different size were selected to increase their sensitivity. Lamb waves were excited by a circular piezoelectric wafer, while another piezoelectric wafer was used to compare their voltage responses. Furthermore, by changing the excitation frequency, the tuning frequency characteristic of the proposed optical fiber sensor was also investigated experimentally.