• Title/Summary/Keyword: Ultrasonic Scanning

Search Result 286, Processing Time 0.025 seconds

UV emission of ZnO:Er films prepared by ultrasonic spray pyrolysis (초음파분무법으로 제조한 ZnO:Er막의 UV 발광 특성)

  • Choi, Mu-Hee;Ma, Tae-Young
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.307-312
    • /
    • 2007
  • The films of Er-doped ZnO (ZnO:Er) were prepared onto MgO wafers by ultrasonic spray pyrolysis at $550^{\circ}C$. The concentration of Er in the deposition source varied from 0.5 wt% to 3.0 wt%. The crystallographic properties and surface morphologies of the films were investigated by X-ray diffraction (XRD) and scanning electron microscope (SEM), respectively. The properties of photoluminescence (PL) for the films were investigated by dependence of PL spectra on the Er concentration in the films. The films were grown as polycrystalline with a dominant direction of [002]. The grain size of the films were reduced by Er-doping. Er-doping enhanced the ultraviolet emission of ZnO:Er films. The ZnO:Er films prepared with the deposition source of 2.0 wt% Er showed the strongest ultraviolet light emission peak among the films in this study.

Effect of Ultrasonic Vibration on Micro-EDM Channel (Micro-EDM 채널가공에서 초음파 가진의 영향)

  • Lim, Heesung;Hong, Minsung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.421-425
    • /
    • 2016
  • Micro-EDM is one of the recent fine-machining technologies. Micro-EDM is widely used in precision processes because products manufactured via EDM are free from workpiece hardness. However, the debris produced during the process cause many problems such as reduced precision of the process. The first solution of this problem involves using the milling hole process. Micro-EDM hole process involves an electrode moving rapidly in the vertical direction via a servo system to disperse debris. However, this process can cause reduced work efficiency owing to contact between the electrode and workpiece. In this study, ultrasonic vibration is added to micro-EDM channel machining. Ultrasonic vibration removes the debris during machining and enables precision machining. Consequently, a clean work environment for the subsequent processes is maintained.

Synthesis and Characterization of Al2O3/ZrO2, Al2O3/TiO2 and Al2O3/ZrO2/TiO2 Ceramic Composite Particles Prepared by Ultrasonic Spray Pyrolysis

  • Shim, In-Soo;Lee, Chang-Seop
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.8
    • /
    • pp.1127-1134
    • /
    • 2002
  • Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutio ns of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle syntheses have been proposed.

Electrical and Structural Properties of ZnO:Pt Films Prepared by Ultrasonic Spray Pyrolysis (초음파분무열분해법으로 제조한 ZnO:Pt막의 전기적 및 구조적 특성)

  • Ma, Tae-Young;Park, Ki-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.66-71
    • /
    • 2004
  • Pt-doped zinc oxide (ZnO:Pt) films were deposited by ultrasonic spray pyrolysis. Resistivity variation with Pt concentration was measured. The Pt distribution in ZnO:Pt films was studied through Auger Electron Spectroscopy (AES). The ZnO:Pt films were annealed in the ambient of air, water vapor and ozone, respectively. The variation in crystallographic properties and surface morphologies with respect to the annealing condition was observed by X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). The resistivity variation of the films with the annealing condition was measured. Finally, Atomic Force Microscopy (AFM) measurements were carried out to study the effects of the annealing on the roughness of ZnO:Pt films.

A Study on Ultrasonic Vibration Cutting of Carbon Fiber Reinforced Plastics (탄소섬유강화 플라스틱의 초음파 진동절삭에 관한 연구)

  • 김정두;이은상;최인휴
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.24-33
    • /
    • 1994
  • The main applications of CFRP are sports, aerospace and general industrial uses including automobiles. As this application fields expands the opportunity of machining, but CFRP is difficult to cut because of delamination of the composites and the short tool life. In this paper, the machinability of multidirectional CFRP by means of ultrasonic vibration cutting, which has been verified experimentally investigated.The experimentally to be highly effective in view of cutting force and surface quality.

A Study on the Distance and Object Recognition Applying the Airborne Ultrasonic Sensor (공중 초음파 센서를 응용한 거리 형상인식에 관한 연구)

  • Han, E.K.;Park, I.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.10-17
    • /
    • 1990
  • Recently, object recognition ultrasonic sensor is being used with automatization of industrial machine. Points which characterize the object can be deleted by measuring the propagation time of ultrasonic impulse and azimuth which gives its maximum amplitude, and from these points shape, position and orientation of the object are deduced. A new measuring method is adopted, where the distance to the object is calculated by sound reflection time which is measured from O-cross point of sound wave, and azimuth is measured by angle indicating maximum amplitude. The measuring accuracy of 1.0mm for distance and $0.5-2^{\circ}$ for azimuth have been accomplished. By rotational scanning of sensor the characteristic point of an object can be known and it gives the information of its shape, position and orientation. Experimental results showed that the object of some complicated shape can be recognized, which suggest its applicability to robot.

  • PDF

A study on Computer-controlled Ultrasonic Scanning Device (컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구)

  • Huh, H.;Park, C.S.;Hong, S.S.;Park, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

Study on Magnetic Property Enhancement of Metal Powders for Magnetic Tape by Using Ultrasonic Dispersion (자기테이프용 Metal Powder의 초음파 분산에 의한 자기적 특성 향상에 관한 연구)

  • Kim, Chang-Gon;Choe, Hyeon-Seung;Jang, Hak-Jin;Yun, Seok-Yeong;Kim, Tae-Ok
    • Korean Journal of Materials Research
    • /
    • v.11 no.11
    • /
    • pp.972-977
    • /
    • 2001
  • It was investigated the effect of ultrasonic treatment on magnetic property of ultra fine magnetic Fe powders ($\alpha$-Fe) for magnetic tape. The properties were characterized with vibrating sample magnetometer (VSM), particle size analyzer (PSA) and scanning electron microscope (SEM). At 4hours ultrasonic treatment of 70 kHz, magnetic properties such as squareness ratio (S.Q. : 0.8868), orientation ratio (O.R. : 2.45) and switching field distribution (S.F. D. : 0.394) before taping were relatively enhanced. Cumulative particle size distribution of less than 5$\mu\textrm{m}$ fine powder was above 90% below 1 hour leaving time after ultrasonic treatment and it was supposed that ultrasonic treatment prevent aggregation. The magnetic values of S.Q. and S.F.D. of tape manufactured at 70 kHz and 4hour ultrasonic treatment were improved from 0.7747, 0.3818 to 0.8037, 0.3706, respectively. Electro-magnetic property used as in-output signal characteristic was improved, which showed that ultrasonic treatment developed the magnetic properties.

  • PDF

Study of Ultrasound Imaging Technique for Diagnosing Osteoporosis (골다공증 진단을 위한 초음파 영상화 진단 기법 연구)

  • Kim, H.J.;Han, S.M.;Lee, J.H.;Lee, M.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.386-392
    • /
    • 2002
  • Ultrasonic has been proposed as an attractive means of detecting bone loss. There have been several commercial ultrasound devices developed for measuring the heel to predict fracture at other bones. However, these devices select only single point of heel bone as measurement site. It causes poor assessment of bone quality due to the error of transducer positioning. In an effort to improve current ultrasound systems, we evaluated the linear scanning method which provides better prediction of bone quality and an accurate image of bone shape. The system used in this study biaxially scans a heel bone using automated linear scanning technique. The results demonstrated that the values of ultrasound parameters varied with different positions within bone specimen. It has been also found that the linear scanning method could better pre야ct bone quality, eliminating the error of transducer positioning.