• Title/Summary/Keyword: Ultrasonic Scanning

Search Result 285, Processing Time 0.029 seconds

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

  • Kwak, Sang-Won;Moon, Young-Mi;Yoo, Yeon-Jee;Baek, Seung-Ho;Lee, WooCheol;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.276-281
    • /
    • 2014
  • Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

A Small Crack Length Evaluation Technique by Electronic Scanning (전자적 스캔에 의한 미소결함길이 평가기법)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detect-ability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination.

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer (초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석)

  • Nam, Young-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

A Study on Detection of Small Defects for MoSi2 by Medical Ultrasonic Testing (의학용 초음파검사기에 의한 MoSi2의 미소결함 탐상)

  • Namkoong, Chai-Kwan;Kim, You-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.9-12
    • /
    • 1995
  • Detection of small defects by medical ultrasonic testing when the thermal sprayed coating by $MoSi_2$ on the metal is done. The defects may occur at the bonded surface. So, the detecting method of the defects by non-destructive in spection is desired. Here, in order to examine the possibility of the detection of the small defects by the ultrasonic. The electronic scanning ultrasonic equipment using an array probe developed as the medical ultrasonic diagnostic equipment is applied for the detection of the metal material defects. It's validity is investigated.

  • PDF

Study on Highly Accuracy Quality Evaluation of Spot Weld by use of Image Processing Technique

    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.38-46
    • /
    • 1996
  • This paper discusses the feasibility of Ultrasonic Nondestructive Evaluation (UNDE) technique for sport weld quality. Ultrasonic c-scan image assisted by image processing technique was used for Nondestructive Evaluation(NDE) of spot weld quality. Ultrasonic testing results obtained were confirmed and compared by Optical Microscope and SAM(Scanning Acoustic Mircroscope) observation of the spot-weld cross section, The results show that the nugget dinameter can be successfully measured with the accuracy of 0.5mm. It was ascertained that ultrasonic c-scan technique is very effective method for the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget. Additional support for the above conclusions is provided by the results for galvanized steel. The ultrasonic results for galvanized welds generally correspond to the results for uncoated steel. Finally, it was found that the above-mentioned technique can be sufficiently applied to NDE method for securing the Quality Assurance(QA) of spot welded products in production line.

  • PDF

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

  • Llena, Carmen;Forner, Leopoldo;Cambralla, Raquel;Lozano, Adrian
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.143-148
    • /
    • 2015
  • Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.

Noncontact techniques for monitoring of tunnel linings

  • White, Joshua;Hurlebaus, Stefan;Shokouhi, Parisa;Wittwer, Andreas;Wimsatt, Andrew
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.2
    • /
    • pp.197-211
    • /
    • 2014
  • An investigation of tunnel linings is performed at two tunnels in the US using complimentary noncontact techniques: air-coupled ground penetrating radar (GPR), and a vehicle-mounted scanning system (SPACETEC) that combines laser, visual, and infrared thermography scanning methods. This paper shows that a combination of such techniques can maximize inspection coverage in a comprehensive and efficient manner. Since ground-truth is typically not available in public tunnel field evaluations, the noncontact techniques used are compared with two reliable in-depth contact nondestructive testing methods: ground-coupled GPR and ultrasonic tomography. The noncontact techniques are used to identify and locate the reinforcement mesh, structural steel ribs, internal layer interfaces, shallow delamination, and tile debonding. It is shown that this combination of methods can be used synergistically to provide tunnel owners with a comprehensive and efficient approach for monitoring tunnel lining conditions.

Local Obstacle Avoidance of an Indoor Mobile Robot Using Lane Method and Velocity Space Command Approach (차선방법과 속도공간 명령 방식을 이용한 실내 주행 로봇의 지역 장애물 회피)

  • 김성철
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.105-110
    • /
    • 1999
  • This paper presents a local obstacle avoidance method for indoor mobile robots using Lane method and velocity Space Command approach. The method locates local obstacles using the information form multi-sensors, such that ultrasonic sensor array and laser scanning sensor. The method uses lane method to determine optimum collision-free heading direction of a robot. Also, it deals with the robot motion dynamics problem to reduce some vibration and guarantee fast movement as well. It yields translational and rotational velocities required to avoid the detected obstacles and to keep the robot heading direction toward goal location as close as possible. For experimental verification of the method, a mobile robot driven by two AC servo motors, equipped with 24 ultrasonic sensor array and laser scanning sensor navigates using the method through a corridor cluttered with obstacle.

  • PDF