• 제목/요약/키워드: Ultrasonic Scanning

검색결과 284건 처리시간 0.027초

튀김 닭고기 가슴살의 품질에 영향을 미치는 초음파 주사 효과 (Effects of Ultrasonic Waves Scanning on the Quality of Fried Chicken Breast)

  • 정인철;문윤희;박경숙;윤동화
    • 동아시아식생활학회지
    • /
    • 제16권2호
    • /
    • pp.192-198
    • /
    • 2006
  • This study was carried out to investigate the effect of ultrasonic wave scanning on the quality of fried chicken breast. The ultrasonic wave scanning time was 0(US-0), 3(US-3), 7(US-7) and 10(US-10) minutes, no respective comparison here. The moisture of raw breast was higher than that of flied chicken, while the crude protein, fat and ash of fried chicken were higher than those of raw breast(p<0.05). The moisture content was influenced by the ultrasonic waves scanning, but the crude protein, fat and ash were not. The $L^*$(lightness) and $b^*$(yellowness) values of fried chicken were higher than those of raw breast but the $a^*$(redness) value of raw breast was higher than that of fried chicken. The $L^*$ value was lowest in US-0, while the $a^*$ value was not significantly different and the $b^*$ value was lowest in US-7 among the fried chicken samples(p<0.05). The fried chicken was not influenced by the ultrasonic wave scanning, indicating that the longer scanning time increased the water holding capacity. The pH ranged from 6.54 to 6.93, and the calorie of fried was higher than that of raw breast, but was not influenced by the ultrasonic wave scanning time. The VBN content ranged from 8.73 to 12.3 mg%. The TBARS value of raw breast was lower than that of flied chicken and was not influenced by the ultrasonic wave scanning time. Total amino acid was highest in raw breast and lowest in US-3(p<0.05). The taste, texture and juiciness were superior with increasing scanning time, but flavor and Palatability were not significantly different among the fried chicken samples(p<0.05).

  • PDF

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

Laser Scanning Vibrometer를 이용한 초음파 이송시스템의 이송 메커니즘에 관한 연구 (A Study on Transport Mechanism of the Ultrasonic Transporting System using Laser Scanning Vibrometer)

  • 정상화;신병수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.841-844
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

나노계면 형성을 위한 초음파 진동자 위치보정을 위한 레이저 스캐닝 기술 (Laser Scanning Technology for Ultrasonic Horn Location Compensation to Modify Nano-size Grain)

  • 김경한;이제훈;김현세;박종권;윤광호
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1121-1126
    • /
    • 2014
  • To compensate location error of ultrasonic horn, the laser scanning system based on the galvanometer scanner is developed. It consists of the 3-Axis linear stage and the 2-Axis galvanometer scanner. To measure surface shape of three-dimensional free form surface, the dynamic focusing unit is adopted, which can maintain consistent focal plane. With combining the linear stage and the galvanometer scanner, the scanning area is enlarged. The scanning CAD system is developed by stage motion teaching and NURBS method. The laser scanning system is tested by marking experiment with the semi-cylindrical sample. Scanning accuracy is investigated by measured laser marked line width with various scanning speed.

APPLICATION OF DIGITAL ULTRASONIC IMAGE CONSTRUCTION SYSTEM FOR THE DETECTION OF CRACKS IN WATER DISTRIBUTION SYSTEM

  • Lee, Hyun-Dong;Kwak, Phill-Jae;Shin, Hyeon-Jae;Jang, You-Hyun
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.99-105
    • /
    • 2006
  • A digital ultrasonic image construction system was developed for the nondestructive detection of cracks in water distribution pipes. The system consists of PC based ultrasonic testing system and a scanning device. The PC based ultrasonic system has an ultrasonic pulse/receive board for the generation and reception of ultrasonic signals, an analogue to digital conversion board for the digitization of the received ultrasonic signals, and transducers for the ultrasonic sensors. Using this system, the digitized ultrasonic signals were properly constructed in accordance with the position information obtained by scanning device that moves an ultrasonic transducer along the outer surface of pipes. In the construction of the ultrasonic signals, signal processing concepts, such as spatial average and array concept, were considered to enhance the resolution of ultrasonic images of pipe wall. Using the developed system, crack detection experiments were performed in both laboratory and field, which shows promise for crack detection in the water distribution system.

레이저 진동 측정기를 이용한 초음파 이송 시스템의 동작특성에 관한 연구 (A Study on the Motion Characteristics of the Ultrasonic Transport System using Laser Scanning Vibrometer)

  • 정상화;신병수;이경형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.155-158
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF

주사형 OPMT 개발을 위한 자왜형 초음파 변환기 설계 및 제작 (Design and Fabrication of Magnetostrictive Transducers for Scanning OPMT Development)

  • 이호철;김형윤;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.856-859
    • /
    • 2005
  • The OPMT(Orientation-adjustable Patch-type Magnetostrictive Transducer) was proposed as a tool for generating and measuring the ultrasonic Lamb wave in plate type structures. This sensor has a lot of new features compared to the traditional piezo-type ultrasonic transducers. As an example, it does not need any kind of wiring for lunching or measuring ultrasonic waves. But it has also definite limitation for practical usage as a nondestructive testing tool in that it cannot help rotating the direction of ultrasonic wave manually. The idea for 'scanning OPMT' is proposed in this respect. Two kinds of basic ideas for rotating the wave direction not manually but electrically are proposed. The fabrication of the transducer and the testing for Identifying the primary characteristics are done for one of the proposed transducers. The results says that there are the possibilities as a new tool for NDE in that the proposed transducer follows well the characteristics of the traditional OPMT. But there are also the 1imitations to overcome.

  • PDF

Crack localization by laser-induced narrowband ultrasound and nonlinear ultrasonic modulation

  • Liu, Peipei;Jang, Jinho;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.301-310
    • /
    • 2020
  • The laser ultrasonic technique is gaining popularity for nondestructive evaluation (NDE) applications because it is a noncontact and couplant-free method and can inspect a target from a remote distance. For the conventional laser ultrasonic techniques, a pulsed laser is often used to generate broadband ultrasonic waves in a target structure. However, for crack detection using nonlinear ultrasonic modulation, it is necessary to generate narrowband ultrasonic waves. In this study, a pulsed laser is shaped into dual-line arrays using a spatial mask and used to simultaneously excite narrowband ultrasonic waves in the target structure at two distinct frequencies. Nonlinear ultrasonic modulation will occur between the two input frequencies when they encounter a fatigue crack existing in the target structure. Then, a nonlinear damage index (DI) is defined as a function of the magnitude of the modulation components and computed over the target structure by taking advantage of laser scanning. Finally, the fatigue crack is detected and localized by visualizing the nonlinear DI over the target structure. Numerical simulations and experimental tests are performed to examine the possibility of generating narrowband ultrasonic waves using the spatial mask. The performance of the proposed fatigue crack localization technique is validated by conducting an experiment with aluminum plates containing real fatigue cracks.

레이저 초음파 기반 반사식 회전 검사 기법을 이용한 오토클레이브 가공 L 형 복합재 구조물의 모서리 검사 (Corner Inspection of Autoclave-cured L-shaped Composite Structure using Pulse-echo Rotation Scanning Scheme based on Laser Ultrasonic)

  • 이영준;이정률;홍성진
    • Composites Research
    • /
    • 제31권5호
    • /
    • pp.246-250
    • /
    • 2018
  • 본 연구에서는 곡면 복합재 구조물의 모서리에 위치한 결함을 검사하고 가시화하기 위해 제안된 레이저 초음파 기반 회전식 검사 기법을 소개한다. 모서리 부위에 결함이 위치한 L 형 복합재 구조물을 레이저 초음파 기반 회전식 검사 기법을 이용하여 검사하였다. L 형 시편은 층간분리 손상을 모사하기 위해 각기 다른 세 가지 깊이에 위치한 인공 결함을 포함하고 있다. 모든 인공 결함이 각각의 위치한 깊이에 따라 다른 시간대에 선명하게 탐지되었다. 검사결과는 제안된 방법이 어떠한 특별한 도구 없이도 곡면 복합재 구조물의 모서리 부위의 검사에 적합하다는 것을 보여준다.

초음파 부상장치의 디스크형 스테이터의 진동 특성 해석 (Vibration Characteristics Analysis of the Disk-Type Stator in Ultrasonic Levitation System)

  • 정상화;최석봉;차경래;김현욱;김광호;박준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.264-268
    • /
    • 2005
  • In the semiconductor and optical industry the non-contact transportation is required for reducing the damages. The ultrasonic levitation is the solution of the problem. In this paper, the ultrasonic levitation system and 3 disk-type stator for levitating various object are proposed. The vibration modes of disks are analyzed with FEM and designed with the analysis results. The 3D vibration profiles of the disks are measured by Laser scanning vibrometer for verifying the vibration characteristics of the system and the amplitudes of the disks and the levitation heights of object are measured for evaluating the performance.

  • PDF