• 제목/요약/키워드: Ultrasonic Power

검색결과 676건 처리시간 0.038초

액체유도체의 절연특성에 미치는 초음파의 영향 (Ultransonic Effect on the Break-Down Characteristics of Liquid Dielectrics)

  • 전춘생;김홍근;홍봉식
    • 전기의세계
    • /
    • 제26권4호
    • /
    • pp.61-67
    • /
    • 1977
  • This paper treats the Ultrasonic effects on the break down characteristics of Liquid Dielectric Material 1) Relative Dielectric constant, Es of Liquid Dielectric Material at a constant temperature decreases in proportion to the irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 2) Power factor of Liquid Dielectric Material at a constant temperature increases in proportion tothe irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 3) Relative resistance of Liquid Dielectric Material at a constant temperature decrease with the irradiated time of Ultrasonic radiation, but the effect of its intensity is very irregular. 4) Break-down strength of Liquid Dielectric Material, at a constant temperature decreases with the irradiated time of Ultrasonic radiation and its intensity, and then reaches to a saturated value.

  • PDF

Distance Measurement by Automatic Peak Detection for Indoor Positioning Using Spread Spectrum Ultrasonic Waves

  • Suzuki, Akimasa;Miyara, Yasuaki;Iyota, Taketoshi;Kim, Young-Bok;Choi, Yong-Woon
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.33-39
    • /
    • 2015
  • In conducting indoor positioning by code division multiple access using spread spectrum ultrasonic waves, it is required to detect signals under the influence of near-far problem occurred by difference on signal power, caused by distance between transmitter and receiver. For discussing robustness to the problem, we verified measuring accuracy on distance from an experiment on a real space with a hardware device where our proposed method is mounted. The proposed method performs automatic signal detection by setting threshold level dynamically. As an experimental result, measurable distance were improved by the proposed method, and measurement errors were up to 50mm in distances from 1000mm to 6000mm; therefore, enough accuracy to realize self-localization or navigation for autonomous mobile robot or human was obtained.

이동로봇을 이용한 곡관(Curved Pipes) 검사용 디바이스 설계 (Device Design for Inspection Curved Pipes using the Mobile Robot)

  • 조현영;최창환;최용제;김승호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1458-1462
    • /
    • 2003
  • High temperature and high pressure heavy water flows through the pipes in atomic power plants. The curved parts of pipes are critical parts in that they change the direction of steam flow, and these parts are especially affected by severe wear. Therefore, most pipes in atomic power plants are tested by non-destructive examination by workers who use ultrasonic sensors to measure the wall thickness of pipes. But not only are these pipes located in a very dangerous environment, but the space is also very limited. For the safety of workers, it is necessary to design a device that uses a mobile robot that can inspect curved pipes. This paper presents the design and construction of a small device that can generate the necessary contact forces between ultrasonic sensors and pipe walls in a limited space. And a mobile robot is used in place ortho worker for successful non-destructive examination.

  • PDF

초음파를 이용한 저전력 Active RFID시스템의 구현가능성에 관한 연구 (Feasibility study of low power active RFID system based on the ultrasonic frequency)

  • 윤기훈;곽철현;김건욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.430-432
    • /
    • 2007
  • This paper proposes the possibility of SonicID system which is the active RFID based on the ultrasonic spectrum instead of using radio frequency. For the feasibility study, various performance indexes are measured in terms of power consumption and signal path loss onto the frequencies of 40KHz, 433MHz, and 2.4GHz. In addition to the line of sight condition, realistic situations are considered for diverse deploying environments. The results of these analyses demonstrate that the SonicID holds the potential to meet the needs of future advanced RFID system in a scalable fashion.

  • PDF

솔잎의 피노실빈 고함유 추출물 생산을 위한 초음파 추출 공정 개발 (Development of Ultrasonication-assisted Extraction Process for Manufacturing Extracts with High Content of Pinosylvin from Pine Leaves)

  • 조용진;이상국;안용현;피재호
    • Journal of Biosystems Engineering
    • /
    • 제28권4호
    • /
    • pp.325-334
    • /
    • 2003
  • Pinosylvin, a stilbenoid phytoalexin, is a health ingredient to be extracted from pine leaves. In this study, ultrasonication-assisted extraction process for manufacturing extracts with high content of pinosylvin from pine leaves was investigated. As process and system variables, ultrasonic power, sonication time and solvent ratio were selected. According to the experimental results, the effective yield of pinosylvin increased with the increase of ultrasonic power and sonication time and the decrease of solvent ratio. When the ultrasonic power of 2400 W/L was added to the solution of pulverized pine leaves of 8 g per 1 L of a solvent for 10 minutes, yield of extracts and purity, effective yield and concentration ratio of pinosylvin were 0.3166 g/g, 0.7247 mg/g, 0.2294 mg/g and 23.0, respectively.

On-Line Estimation of Partial Discharge Location in Power Transformer

  • Yoon, Yong-Han;Kim, Jae-Chul;Chung, Chan-Soo;Kwak, Hee-Ro;Kweon, Dong-Jin
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권2호
    • /
    • pp.45-51
    • /
    • 1996
  • This paper presents a neural network approach for on-line estimation of partial discharge(PD) location using advanced correlation technique in power transformer. Ultrasonic sensors detect ultrasonic signals generated by a PD and the proposed method calculates time difference between the ultrasonic signals at each sensor pair using the cross-correlation technique applied by moving average and the Hamming window. The neural network takes distance difference as inputs converted from time difference, and estimates the PD location. Case studies showed that the proposed method using advanced correlation technique and a neural network estimated the PD location better than conventional methods.

  • PDF

배관 용접부 초음파검사 시스템 개발 (Development of Ultrasonic Testing System for Piping Welds)

  • 최성남;김형남;유현주;조현준;황원걸
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.331-338
    • /
    • 2008
  • 원자력 발전소 설비의 건전성 확인을 위해서 주기적일 초음파탐상검사가 수행되고 있다. 수동 초음파탐상검사는 검사자의 경험 및 현장여건에 따라 균일한 검사 품질에 영향을 주게 되나, 자동 초음파탐상검사는 스캐너의 적용으로 검사 결과의 일관성을 유지하고, 디스크에 저장된 검사결과는 제3자에 의한 검토가 가능하다. 국내 원자력발전소에서 사용 중인 상용 초음파검사 시스템은 장비 구매, 교육 및 교정 등을 해외에 의존하고 있는 실정이다. 본 연구에서는 초음파 하드웨어, 배관 스캐너 및 초음파검사 프로그램(SonicWizard)으로 구성된 초음파검사 시스템을 개발하였다. 개발된 시스템의 검증을 위해 원전 배관 용접부의 자동 초음파검사 기량검증을 응시하여 인증을 획득하였으며, 현장 배관 감육 자동 초음파검사를 수행하여 정확한 감육상태를 확인함으로써 개발된 자동 초음파검사 시스템의 유효성을 확인하였다.

초음파 핵연료 세정장비의 시스템 구성과 제거된 크러드의 정량적 무게 측정법 (System Configuration of Ultrasonic Nuclear Fuel Cleaner and Quantitative Weight Measurement of Removed CRUD)

  • 신중철;이학윤;성운학;주영종;김용찬;한욱진
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2024
  • Crud is a corrosion deposit that forms in equipments and piping of nuclear reactor's primary systems. When crud circulates through the reactor's primary system coolant and adheres to the surface of the nuclear fuel cladding tube, it can lead to the Axial Offset Anomaly (AOA) phenomenon. This occurrence is known to potentially reduce the output of a nuclear power plant or to necessitate an early shutdown. Consequently, worldwide nuclear power plants have employed ultrasonic cleaning methods since 2000 to mitigate crud deposition, ensuring stable operation and economic efficiency. This paper details the system configuration of ultrasonic nuclear fuel cleaning equipment, outlining the function of each component. The objective is to contribute to the local domestic production of ultrasonic nuclear fuel cleaning equipment. Additionally, the paper introduces a method for accurately measuring the weight of removed crud, a crucial factor in assessing cleaning effectiveness and providing input data for the BOA code used in core safety evaluations. Accurate measurement of highly radioactive filters containing crud is essential, and weighing them underwater is a common practice. However, the buoyancy effect during underwater weighing may lead to an overestimation of the collected crud's weight. To address this issue, the paper proposes a formula correcting for buoyancy errors, enhancing measurement accuracy. This improved weight measurement method, accounting for buoyancy effects in water, is expected to facilitate the quantitative assessment of filter weights generated during chemical decontamination and system operations in nuclear power plants.

수치실험을 통한 초음파 결합형 SBR 호기성 소화의 거동 예측 (Performance Estimation of SBR Aerobic Digestion Combined with Ultrasonication by Numerical Experiment)

  • 김성홍;김동한;이동우
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.815-826
    • /
    • 2013
  • Using a developed mathematical model and calibrated kinetic constants, numerical experiments for a aerobic digestion of wastewater sludge by SBR aerobic digestion process combined with ultrasonication (USSBR) were performed in this study. It simulated well the phenomena of the decomposition of particulate organics and the release of organic nitrogen and transformation. To achieve 40 % of particulate organics removal, USSBR process requires only 6 days of SRT and 14 W/L of ultrasonic power whereas SBR aerobic digestion process requires 12 days of SRT. Based on the model simulation results, an empirical equation was presented here. This equation will be used to predict digestion efficiency for the given variables of SRT and ultrasonic power dose. USSBR aerobic digestion process can reduce the nitrogen concentration. The optimal operation strategy for the simultaneous removal of solids and soluble nitrogen in this process is estimated to 7 days of SRT with 14 W/L of ultrasonic power dose while anoxic period was 6 hours out of 24 hours of cycle time. In this condition, 40 % of particulate organics as well as 36 % of total nitrogen will be removed and the soluble nitrogen concentration of the centrate will be lower less then 40 mg/L.

풍력 발전용 블레이드 접합부의 결함 검출을 위한 일정가압 메커니즘 설계 및 실험 (A Design and Experiment of Pressure and Shape Adaptive Mechanism for Detection of Defects in Wind Power Blade)

  • 임선;임승환;정예찬;지수정;남문호
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권3호
    • /
    • pp.224-235
    • /
    • 2017
  • Purpose: Reliability is the most important factor to detect defects as wind turbines are deployed in large blades. The methods of detecting defects are various, such as non-destructive inspection and thermal imaging inspection. We propose the phased array ultrasonic testing method of non-destructive testing. Methods: We propose the active pressure mechanism for wind power blade. The phase array ultrasonic inspection method is used for fault detection inner blade surface. Controlled pressure of mechanism with respect to z-axis is important for guarantee the result of phase array ultrasonic inspection. The model based control and proposed mechanism are utilized for overall system stability and effectiveness of system. Result: The result of proposed pressure mechanism B is more stable than A. Convergence speed is also faster than A. Conclusion: We confirmed the performance of the proposed constant pressure mechanism through experiments. Non-destructive testing was applied to the specimen to confirm the reliability of detecting defects.