• Title/Summary/Keyword: Ultrasonic Imaging

Search Result 199, Processing Time 0.029 seconds

Nondestructive Deterioration Diagnosis and Environmental Investigation of the Stupa of the Buddhist Monk Soyo in Baegyangsa Temple, Jangseong (장성 백양사 소요대사탑의 비파괴 훼손도 진단과 입지환경 검토)

  • Kim, Yuri;Lee, Myeong Seong;Chun, Yu Gun;Lee, Mi Hye;Jwa, Yong-Joo
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.4
    • /
    • pp.52-63
    • /
    • 2016
  • The Stupa of Buddhist Monk Soyo in Baegyangsa temple, Jangseong, was erected to pay a tribute to the achievement of the Buddhist monk Soyo, who worked for Baegyangsa temple as a chief monk, and is a bellshaped stupa with the detailed pattern of a Korean traditional buddhist bell. It is composed of pinkish-grey sandstone and the body of the stupa was damaged by longitudinal cracks on the front and back areas and the exfoliation caused break-out in the most part of the sculpture on the left and right areas. According to the ultrasonic test and infrared thermography analysis for physical deterioration diagnosis, most weathering aspects appeared on the body of the stupa and some exfoliated part that could not be seen with the naked eye was detected 6.1% and 5.9% on the left and right side respectively. Hyperspectral imaging analysis was also carried out to assess biological deterioration. According to the result, the surface of the stupa was covered 71.8 ~ 79.9% with vegetation like algae, lichen and moss. NDVI(Normalized Difference Vegetation Index) was higher relatively on the bottom part near the ground, right and back areas of the stupa. Therefore conservation treatment for the exfoliated part and bio-deterioration is necessary and the environment condition needs to be fixed to prevent extra damages on the stupa.

Intensity of Intraoperative Spinal Cord Hyperechogenicity as a Novel Potential Predictive Indicator of Neurological Recovery for Degenerative Cervical Myelopathy

  • Guoliang Chen;Fuxin Wei;Jiachun Li;Liangyu Shi;Wei Zhang;Xianxiang Wang;Zuofeng Xu;Xizhe Liu;Xuenong Zou;Shaoyu Liu
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1163-1171
    • /
    • 2021
  • Objective: To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy. Materials and Methods: Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis. Results: The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028). Conclusion: For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.

Survey of Demand for Medical Devices in Korean Medicine (한방의료기기 개발 수요에 대한 조사연구)

  • Kim, Ji Hye;Kim, Keun Ho;Kim, Jaeuk U.
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.103-115
    • /
    • 2014
  • Objectives: The purpose of this survey was to investigate the need for new medical devices based on opinions of members of the Korean medical society. Methods: We distributed two independent questionnaires sequentially over two-week intervals to 16,510 doctors via the Korean Medical Society, and received replies from 888 and 928 doctors, respectively. The survey was carried out through a web-based questionnaire system. The first questionnaire focused on demand for new diagnostic and therapeutic medical devices that are specific for Korean medicine (KM). In contrast, the second questionnaire focused on demand for new hybrid medical devices which are useful both in Western medicine (WM) and KM. Results: In purchase intention of Korean medical devices (KMDs), demand for diagnostic devices was greater than for therapeutic ones. Among diagnostic devices, the purchase intention of 'imaging devices' ranked the highest and was followed by 'musculoskeletal diagnostic devices'. Among therapeutic KMDs, the purchase intention of 'musculoskeletal treatment devices' ranked the highest, followed by 'cranial nerve rehabilitation devices'. In the purchase intention of hybrid medical devices that can be used both in WM and KM, 'ultrasonic-based medical device' ranked the highest, followed by 'MRI-based medical device'. Conclusions: There is increasing demand for clinically useful medical devices among Korean medical doctors. Within demand for new devices, hybrid devices that can be used in both WM and KM were most strongly desired. This survey will be useful in establishing strategic plans for the development of medical devices in KM. Keywords: Korean medicine, medical device, demand survey, questionnaire.

Effects of Pelvic Compression Belt on The Thickness of Transversus Abdominis During Active Straight Leg Raising in Healthy Subjects (골반압박벨트가 정상인의 능동 하지직거상 시 복횡근 굵기에 미치는 영향)

  • Kim, Soo-Hyun;Pak, Mi-Hee;Sim, Jin-A;Lee, Kyung-A;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • Background: The objective of this study was to determine the effectiveness of the pelvic compression belt (PCB) on the thickness of the transversus abdominis (TrA) during active straight leg raising (ASLR). Methods: Thirty healthy subjects (10 men and 20 women) volunteered to participate in this study. The thickness of TrA was measured using a real-time ultrasonic diagnostic imaging system. Subjects were instructed to rest in a resting (hook-lying) position and to perform ASLR with and without the PCB. The PCB was positioned below the anterior superior iliac spine with stabilizing pressure from elastic bands. Results: In the resting position and during ASLR, the thickness of the TrA significantly differed between subjects with and without PCB (p<.05). In addition, there was a significant interaction between the measurement position and the presence or absence of PCB (p<.05). Conclusions: These findings suggest that the PCB may affect deep core muscles such as TrA during various activities. Further studies are required to generalize the results of the present study.

  • PDF

Development and Evaluation of System for 3D Visualization Model of Biological Objects (3차원 생물체 가시화 모델 구축장치 개발 및 성능평가)

  • Hwang, H.;Choi, T. H.;Kim, C. H.;Lee, S. H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.545-552
    • /
    • 2001
  • Nondestructive methods such as ultrasonic and magnetic resonance imaging systems have many advantages but still much expensive. And they do not give exact color information and may miss some details. If it is allowed to destruct a biological object to obtain interior and exterior informations, 3D image visualization model from a series of sliced sectional images gives more useful information with relatively low cost. In this paper, a PC based automatic 3D visualization system is presented. The system is composed of three modules. The first module is the handling and image acquisition module. The handling module feeds and slices a cylindrical shape paraffin, which holds a biological object inside the paraffin. And the paraffin is kept being solid by cooling while being handled. The image acquisition modulo captures the sectional image of the object merged into the paraffin consecutively. The second one is the system control and interface module, which controls actuators for feeding, slicing, and image capturing. And the last one is the image processing and visualization module, which processes a series of acquired sectional images and generates a 3D volumetric model. To verify the condition for the uniform slicing, normal directional forces of the cutting edge according to the various cutting angles were measured using a strain gauge and the amount of the sliced chips were weighed and analyzed. Once the 3D model was constructed on the computer, user could manipulate it with various transformation methods such as translation, rotation, and scaling including arbitrary sectional view.

  • PDF

A pictorial review of signature patterns living in musculoskeletal ultrasonography

  • Kim, Su Young;Cheon, Ji Hyun;Seo, Won Jun;Yang, Geun Young;Choi, Yun Mi;Kim, Kyung Hoon
    • The Korean Journal of Pain
    • /
    • v.29 no.4
    • /
    • pp.217-228
    • /
    • 2016
  • The musculoskeletal system is mainly composed of the bones, muscles, tendons, and ligaments, in addition to nerves and blood vessels. The greatest difficulty in an ultrasonographic freeze-frame created by the examiner is recognition of the targeted structures without indicators, since an elephant's trunk may not be easily distinguished from its leg. It is not difficult to find descriptive ultrasonographic terms used for educational purposes, which help in distinguishing features of these structures either in a normal or abnormal anatomic condition. However, the terms sometimes create confusion when describing common objects, for example, in Western countries, pears have a triangular shape, but in Asia they are round. Skilled experts in musculoskeletal ultrasound have tried to express certain distinguishing features of anatomic landmarks using terms taken from everyday objects which may be reminiscent of that particular feature. This pictorial review introduces known signature patterns of distinguishing features in musculoskeletal ultrasound in a normal or abnormal condition, and may stir the beginners' interest to play a treasure-hunt game among unfamiliar images within a boundless ocean.

Defect Monitoring of a Wind Turbine Blade Surface by using Surface Wave Damping (표면파 기반의 풍력발전기 블레이드 표면상태 실시간 모니터링에 관한 연구)

  • Kim, Kyung-Hwan;Yang, Young-Jin;Kim, Hyun-Bum;Yang, Hyung-Chan;Lim, Jong-Hwan;Choi, Kyung-Hyun
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.90-94
    • /
    • 2017
  • These days much efforts are being dedicated to wind power as a potential source of renewable energy. To maintain effective and uniform generation of energy, defect preservation of turbine blade is essential because it directly takes effects on the efficiency of power generation. For the effective maintenance, early measurements of blade defects are very important. However, current technologies such as ultrasonic waves and thermal imaging inspection methods are not suitable because of long inspection time and non-real time inspection. To supplement the problems, the study introduced a method for real time defect monitoring of a blade surface based on surface wave technology. We examined the effect of various parameters such as micro-cracks and peelings on the propagation of surface wave.

Infantile Hypertrophic Pyloric Stenosis -Clinical Differences between Premature and Full-term Infants (미숙아와 만삭아에서의 비후성 유문 협착증의 임상적 차이)

  • Lee, Suk-Koo;Kim, Seong-Hwan;Lee, Woo-Yong;Kim, Hyun-Hahk
    • Advances in pediatric surgery
    • /
    • v.4 no.1
    • /
    • pp.34-38
    • /
    • 1998
  • Infantile hypertrophic pyloric stenosis(IHPS) is common in full-term babies, and relatively rare in prematures. The diagnosis of IHPS in premature infants may be obscured because of the lack of classic symptoms and signs and the absence of the standard criteria for ultrasonic diagnosis. The purpose of this study is to discover the clinical differences between premature and full-term infants with pyloric stenosis, and determine the appropriate diagnostic methods for early diagnosis in premature infants. The clinical records of 52 IHPS patients who had been operated upon from October, 1994 to April, 1997 were reviewed. The incidence of IHPS in premature infants was 25 %. The onset of symptom was 4.7 weeks of age in premature, and 2.9 weeks in full-term babies. Diagnosis was established by typical symptoms. signs. and diagnostic imaging studies. In two premature infants, diagnosis was confirmed by upper gastrointestinal(GI) series, because ultrasonography did not meet the diagnostic criteria. Two premature infants initially diagnosed as gastroesophageal reflux by esophagography. were found to have IHPS by upper GI series. For the diagnosis of IHPS, a new set of criteria for premature babies has to be developed.

  • PDF

A study of the high resolution Ultrasound Diagnostic system for Dermatology (피부학(Dermatology)을 위한 고해상도 초음파 진단 장치에 관한 연구)

  • Lew, Jeom-Soo;Lim, Chun-Sung;Kim, Young-Kil
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.6
    • /
    • pp.66-71
    • /
    • 1998
  • High spatial resolution ultrasonic imaging is necessary in several fields of investigation, in order to permit greater precision of clinical diagnosis in the dermatology, ophthalmology etc. We present a B-mode scan system using sector scanning probe of 20MHz center frequency. This developed system allow the high resolution image of 250${\mu}m$ in lateral and 80${\mu}m$ in axial, which of display the size of a $5mm {\times} 5mm$ image with 20 frames/sec. We have shown the images of various structural elements of the human skin and of the nail. We have compared the skin images obtained for each of the different age and we have shown in a general with the age, the atrophy of the skin thickness and the appearance of the abnormal hypoechogene band under epidermis (named SENEB : Sub Epidermal Non Echogene Band).

  • PDF

Extraction of Lumbar Multifidus Muscle using Ultrasound Imaging (초음파 영상에서 다열근 추출)

  • Kim, Kwang-Baek;Shin, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • In this paper, we propose a new method for extracting muscles from lumbar images. The proposed method sets areas without distortions with field expert's assistance as areas of measuring interest and removing noises from initial ultrasonic videos. Then, the method emphasizes the brightness contrast with Ends-in search stretching algorithm and separate thoracic vertebra from subcutaneous fat area using morphological characteristics. 4-directions contour tracing algorithm is applied to extract the bottom of subcutaneous fat area. Extracting thoracic vertebra area requires noise removal and morphological characteristics as well among candidate areas obtained by controlling min-max brightness. The thickness of muscles is then defined as the length between subcutaneous fat area and extracted thoracic vertebra. The experiment which consists of 368 image analysis verifies that the proposed method is more effective in measuring the thickness of muscles than before.