• Title/Summary/Keyword: Ultrasonic Experiment

Search Result 430, Processing Time 0.022 seconds

Preliminary Study of the Measurement of Foreign Material in Galvanic Corrosion Using Laser Ultrasonic

  • Hong, Kyung Min;Kang, Young June;Park, Nak Kyu;Choi, In Young
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.323-327
    • /
    • 2013
  • A laser ultrasonic inspection system has the advantage of nondestructive testing. It is a non-contact mode using a laser interferometer to measure the vertical displacement of the surface of a material caused by the propagation of ultrasonic signals with the remote ultrasonic generated by laser. After raising the ultrasonic signal with a broadband frequency range using a pulsed laser beam, the laser beam is focused to a small point to measure the ultrasonic signal because it provides an excellent measurement resolution. In this paper, foreign materials are measured by a non-destructive and non-contact method using the laser ultrasonic inspection system. Mixed foreign material on the corroded part is assumed and the laser ultrasonic experiment is conducted. An ultrasonic wave is generated by pulse laser from the back of the specimen and an ultrasonic signal is acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer (CFPI). The characteristic of the ultrasonic signal of existing foreign material is analyzed and the location and size of foreign material is measured.

A Study on the Shift Register-Based Multi Channel Ultrasonic Focusing Delay Control Method using a CPLD for Ultrasonic Tactile Implementation (초음파 촉각 구현을 위한 CPLD를 사용한 Shift Register기반 다채널 초음파 집속 지연 제어 방법에 대한 연구)

  • Shin, Duck-Shick;Park, Jun-Heon;Lim, Young-Cheol;Choi, Joon-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.324-329
    • /
    • 2022
  • This paper proposes a shift-register-based multichannel ultrasonic focusing delay control method using a complex programmable logic device (CPLD) for a high resolution of ultrasonic focusing system. The proposed method can achieve the ultrasonic focusing through the delay control of driving signals of each ultrasonic transducer of an ultrasonic array. The delay of the driving signals of all ultrasonic channels can be controlled by setting the shift register in the CPLD. The experiment verified that the frequency of the clock used for the delay control increased, the error of the focusing point decreased, and the diameter of the focusing point decreased as the length of the shift register in the proposed method. The proposed method used only one CPLD for ultrasonic focusing and did not require to use complex hardware circuits. Therefore, the resources required for the design of an ultrasonic focusing system could be reduced. The proposed method can be applied to the fields of human computer interaction (HCI), virtual reality (VR) and augmented reality (AR).

Analysis of Ultrasonic Linear Motor Using the Finite Element Method and Equivalent Circuit

  • Park, Jong-Seok;Joo, Hyun-Woo;Lee, Chang-Hwan;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.4
    • /
    • pp.159-164
    • /
    • 2003
  • In this paper, a three-dimensional finite element method and construction of equivalent-circuit for a linear ultrasonic motor are presented. The validity of three-dimensional finite element routine in this paper is experimentally confirmed by analyzing impedance of a piezoelectric transducer. Using this confirmed finite element routine, impedance and vibration mode of a linear ultrasonic motor are calculated. Elliptical motion of contact point between vibrator and rail of the linear ultrasonic motor is shown for determination of contact points. By using the finite element method and analytic equations, characteristics of the linear ultrasonic motor, such as thrust force, speed, losses, powers and efficiency, are calculated. The results are confirmed by experiment. Finally, equivalent circuit parameters of the linear ultrasonic motor are obtained using the three-dimensional finite element method and analytic equations.

Positioning Accuracy on Robot Self-localization by Real-time Indoor Positioning System with SS Ultrasonic Waves

  • Suzuki, Akimasa;Kumakura, Ken;Tomizuka, Daisuke;Hagiwara, Yoshinobu;Kim, Youngbok;Choi, Yongwoon
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.100-111
    • /
    • 2013
  • Indoor real-time positioning for multiple targets is required to realize human-robot symbiosis. This study firstly presents positioning accuracy on an autonomous mobile robot controlled by 3-D coordinates that is obtained by a real-time indoor positioning system with spread spectrum (SS) ultrasonic signals communicated by code-division multiple access. Although many positioning systems have been investigated, the positioning system with the SS ultrasonic signals can measure identified multiple 3-D positions in every 70 ms with noise tolerance and error within 100 mm. This system is also robust to occlusion and environmental changes. However, thus far, the positioning errors in an autonomous mobile robot, controlled by these systems using the SS ultrasonic signals, have not been evaluated as an experimental study. Therefore, a positioning experiment for trajectory control is conducted using an autonomous mobile robot and our positioning system. The effectiveness of this positioning method for robot self-localization is shown, from this experiment, because the average control error between the target position and the robot's position at 29 mm is obtained.

EXPERIMENTAL STUDY ON THE CHARACTERISTICS OF RIVERBED MATERIALS USING AN ULTRASONIC SENSOR

  • Yeo, Woon-Kwang;Jang, Bok-Jin;Lee, Jong-Kook;Kim, Young-Bin
    • Water Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • The scouring process is complex and subject to many factors. Recently, experiments for real-time bridge scour monitoring have been active as means for a more reliable scour prediction. Riverbed materials are an important factor in bridge scouring; therefore, an accurate estimation of riverbed material is critical in predicting a scour. As a part of this approach, an ultrasonic sensor, which can not only detect river bottom during floods but can also be installed lose to the underwater structures, was developed. This sensor is able to map the river bottom using an ultrasonic waves with the characteristics of the returning wave, reflected from an object or bottom ground. The reflected wave is unique according to the situations, or materials below. Therefore, it would be possible to identify the consisting materials of a riverbed if we could reveal each characteristic in the received signals. In this study, a preliminary experiment was performed in the laboratory to identify and classify received signals, which is unique to each material. The analysis of this experiment gives the graph, which makes it possible to identify materials of the river bottom through the ultrasonic signals. The proposed graph was verified through a comparison with the actual field data measured in river.

  • PDF

A Study on the Atomization Characteristics of the Ultrasonic-Energy-Irradiation High Viscosity Biodiesel Blended Fuel (초음파 에너지 조사 고 점도 바이오디젤 혼합연료의 미립화 특성에 관한 연구)

  • Song Yong-Seek;Yang In-Kwon;Kim Bong-Seock;Ryu Jung-In
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.235-241
    • /
    • 2004
  • This experiment was undertaken to investigate the atomization characteristics of the high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Test fuels were conventional diesel fuel and biodiesel one. We compared to the characteristics of viscosity and surface tension, SMD between high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Sauter mean diameter was measured under the variation of the spray distance. Viscosity and surface tension were measured under the variation of the time trace. To measure the droplet size, we used the Malvern system 2600c. Droplet size distribution was analyzed from the result data of Malvern system. Through this experiment, we found that the condition of the ultrasonic energy irradiation situation had smaller Sauter mean diameter of droplet, viscosity and surface tension than those of the conventional situation.

Predicting the Firmness of Apples using a Non-contact Ultrasonic Technique

  • Lee, Sangdae;Park, Jeong-Gil;Jeong, Hyun-Mo;Kim, Ki-Bok;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.38 no.3
    • /
    • pp.192-198
    • /
    • 2013
  • Purpose: Methods for non-destructive estimation of product quality have been reported in various industrial fields, but the application of ultrasonic techniques for the agricultural products of potatoes, pears, apples, watermelons, kiwis and tomatoes etc. have been rarely reported since the application of a contact-type ultrasonic transducer in agricultural products is very difficult. Therefore, this study sought to determine the firmness of apples using non-contact ultrasonic techniques. Methods: For this experiment, an ultrasonic experimental tester using a non-contact ultrasonic transducer was created, and a signal processing program was used to analyze the acquired ultrasonic reflected signal. Also, a universal testing machine was used to measure firmness parameters of the apples such as bioyield strength, a firmness factor, after the ultrasonic tests had been performed. Results: Six distance correction factors were calculated to obtain consistent values of ultrasonic properties regardless of the distance between the transducer and the surface of the subject. We developed prediction models of the bioyield strength using the distance correction factors. Conclusions: The optimum prediction model of the bioyield strength of apples using a non-contact ultrasonic technique was a multiple regression model ($R^2=0.9402$).

Crack localization by laser-induced narrowband ultrasound and nonlinear ultrasonic modulation

  • Liu, Peipei;Jang, Jinho;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • v.25 no.3
    • /
    • pp.301-310
    • /
    • 2020
  • The laser ultrasonic technique is gaining popularity for nondestructive evaluation (NDE) applications because it is a noncontact and couplant-free method and can inspect a target from a remote distance. For the conventional laser ultrasonic techniques, a pulsed laser is often used to generate broadband ultrasonic waves in a target structure. However, for crack detection using nonlinear ultrasonic modulation, it is necessary to generate narrowband ultrasonic waves. In this study, a pulsed laser is shaped into dual-line arrays using a spatial mask and used to simultaneously excite narrowband ultrasonic waves in the target structure at two distinct frequencies. Nonlinear ultrasonic modulation will occur between the two input frequencies when they encounter a fatigue crack existing in the target structure. Then, a nonlinear damage index (DI) is defined as a function of the magnitude of the modulation components and computed over the target structure by taking advantage of laser scanning. Finally, the fatigue crack is detected and localized by visualizing the nonlinear DI over the target structure. Numerical simulations and experimental tests are performed to examine the possibility of generating narrowband ultrasonic waves using the spatial mask. The performance of the proposed fatigue crack localization technique is validated by conducting an experiment with aluminum plates containing real fatigue cracks.

Atomization Characteristics Experiment of Pintle Type Nozzle by the PDPA (PDPA에 의한 Pintle형 노즐의 미립화 특성실험 -식물유를 중심으로-)

  • 나우정;유병구;정진도
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 1998
  • A simplified experiment was performed to figure out the atomization characteristics of highly viscous liquid of rice-bran oil by applying ultrasonic energy to improve the atomization of spray droplets. A spray system, an ultrasonic system, and three kinds of pintle-type nozzles(pin-edge angle: 5 , 10 , 15 ) were manufactured. To investigate the effects of ultrasonic energy on the atomization of a highly viscous liquid, a phase doppler particle analyzer was used for the measurement and calculation of spray droplets data. Nozzle opening pressures were chosen of 3 levels, i.e, 10, 13, 16 MPa. As a result, it could be concluded that the ultrasonic energy was effective to improve the spray atomization when applied to the fuel by means of 3 different nozzles because of the effects of the liquid fuel cavitation and relaxation between molecules caused by ultrasonic energy. The improvement rate of the spray atomization by the ultrasonic spray atomization by the ultrasonic spray compared with the conventional spray was about 10% increase in the case of pintle type nozzles. With the increase of pin-edge angles the distribution lines by nozzle opening pressures are declined for both conventional and ultrasonic sprays. This means that the increase of the pin-edge angle improves the atomization of sprays.

  • PDF

Ultrasonic Washing Performance Analysis for Eco-friendly Wet Cleaning (친환경 웨트클리닝을 위한 초음파 세탁성능 분석)

  • Jeongwon Mun;Jungsoon Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.2
    • /
    • pp.353-370
    • /
    • 2023
  • In this study, the performance of ultrasonic cleaners for ultrasonic washing, which is one of the wet cleaning methods, was evaluated. The washing performances of ultrasonic cleaners were compared with commercial washing machines under normal and wool courses based on different parameters such as detergency, wrinkle formation, fabric damage, dimensional stability, and germ removal ability. Cotton, silk and wool were used in this experiment. Results revealed that the ultrasonic washing detergency of cotton fabrics was lower than that of commercial washing machines under the normal course and similar to that of commercial washing machines under the wool course. Detergency of silk fabrics was similar under both normal and wool courses. In terms of wrinkle formation and dimensional stability, ultrasonic cleaners showed lesser wrinkles and lower shrinkage than commercial washing machines. Considering damage evaluation, ultrasonic cleaners more effectively removed soil without damaging fabrics compared with commercial washing machines. The bacteria removal rate of both cotton and silk was more effective than the wool course of a commercial washing machine. Thus, this study compares the performance of ultrasonic cleaners and commercial washing machines and provides meaningful results related to ultrasonic washing performance.