• Title/Summary/Keyword: Ultrasonic Experiment

Search Result 430, Processing Time 0.029 seconds

A Study on Screening of Surface Waves by Wave Barriers (방진구조물에 의한 표면파 산란해석)

  • Lee, Jong-Seh;Kim, Hee-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.578-581
    • /
    • 2004
  • In this paper numerical and experimental studies are conducted to examine the wave screening effectiveness of wave barriers. The numerical study is based on a finite element model of a 'sandbox' with Lysmer-Kuhlemeyer-type absorbing boundaries. Using the model, the screening effectiveness of wave barriers is studied for different barrier dimensions and distances between the source/receiver and the wave barrier. The results of the numerical modeling are compared with those of the ultrasonic experiment which is performed on an acrylic block with a drilled rectangular cut. Finally, the problem of ground transmitting vibration from a traveling train is numerically treated as a real-world application and the results are discussed in some detail.

  • PDF

Effect of Ultrasonic Bath in Preparing Specimens for Transmission Electron Microscopy (전자현미경 시료 제작에 있어 Ultrasonic bath의 유용성에 관한 연구)

  • Lim, Byung-Soo;Choi, Jeung-Mok;Kang, Dae-Young
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.315-328
    • /
    • 1998
  • The present study was carried out to investigate the effect of ultrasonic bath in tissue preparation for transmission electron microscopy. The method used standard reagents and media, and employed ultrasonic bath agitation to accelerate fluid exchange. The liver kidney, stomach and cardiac muscle tissues of male Sprague-Dawley rats were used for the experiment, and the experimental design was divided into 4 groups; The control group using rotators (Traditional method, 1,625 mins) and the three experimental groups using ultrasonic bath (UB) in the primary fixation through the infiltration processes (UB I; 62.5 mins, UB II; 125 mins, UB III; 250 mins). The results were as follows; 1. In the control group, tissues were easily sectioned, and showed well preserved intact membranes, and cell organelles such as mitochondria, lysosome, peroxisome, rough endoplasmic reticulum and smooth endoplasmic reticulum. 2. In the UB treated group I, tissues showed holes due to the inadequate removal of both water and fluids used in the dehydration process. Also the mitochondria of cell organelles, especially, showed swollen intracristal spaces and dense matrices due to poor fixation. 3. In the UB treated group II, tissues showed good preservation of cell organelles and specimen slice sections. Also, no holes were observed. 4. In the UB treated group III, tissues showed leaching of structural components in the cytoplasm, but no holes were observed. In conclusion, the ultrasonic bath procedure takes approximately 120 minutes from specimen fixation to resin infiltration and gives excellent results.

  • PDF

Development of experimental water level measuring device using an Arduino and an ultrasonic sensor (아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발)

  • Yoo, Moonsung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.143-147
    • /
    • 2018
  • Water levels are measured in various fields such as sewage treatment plants, water treatment plants, rivers, dams, factory storages' tanks. Ultrasonic instruments for water level measurement are expensive and are used for industrial field. Rapid advances in electronics have made it possible to build a wide variety of measurement, monitoring and control functions at low cost. This study was started to make ultrasonic level measurement system at low price. The system was constructed with an Arduino, an ultrasonic sensor and a temperature sensor for use in the experiment. The ultrasonic sensor measures the time from the sensor to the liquid surface. The temperature sensor measures the atmospheric temperature and improves the accuracy of the ultrasonic distance measurement by correcting the sound speed. Arduino controls measurements and calculates the water level. All components of the system are assembled into a device holder. Experiments with this system show that the water level measured by the system is very close to the actual value. This system is also inexpensive and easy to install and maintain, making it suitable for laboratory use.

Ground Altitude Measurement Algorithm using Laser Altimeter and Ultrasonic Rangefinder for UAV (레이저 고도계와 초음파 거리계를 이용한 무인항공기 지면고도측정 알고리즘 설계)

  • Choi, Kyeung-Sik;Hyun, Jung-Wook;Jang, Jae-Won;Ahn, Dong-Man;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.749-756
    • /
    • 2013
  • This paper presents an algorithm concerning the ground altitude measurement using a laser altimeter and an ultrasonic rangefinder for UAV(Unmanned Aerial Vehicle). A simple ground test conducted using the laser altimeter and ultrasonic rangefinder that are used for conducting the low altitude measurement of UAV and identify the characteristics of each sensor. Especially, the disadvantages of the laser altimeter were checked through the ground test. After that who those are participated in this paper planned the algorithm which is complemented by the ultrasonic rangefinder and the experiment was conducted. The laser altimeter and the ultrasonic rangefinder were fused by a loosely coupled method by Kalman filter. The paper shows that stable value of altitude complemented by the ultrasonic rangefinder that covers the laser altimeter's drawbacks can be measured through the ground test.

Investigation for Optimization of Ultrasonic Soil-Washing Process for Remediation of Diesel Contaminated Soil (유류오염토양의 복원을 위한 초음파 토양세척 공정의 최적화에 대한 연구)

  • Park, Beom-Guk;Son, Young-Gyu;Hwang, An-Na;Khim, Jee-Hyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Determination of ultrasonic frequency and experimental design approach to optimization of ultrasonic soil-washing process for remediation of diesel contaminated soil were investigated. Ultrasonic frequencies of 35, 72, and 100 kHz were used for determination of optimal frequency. $MINITAB^{(R)}$ program was used for experimental design of optimal washing condition. The optimal ultrasonic frequency was 35 kHz. Even though the number of cavitation bubble is little, however cavitation bubbles involving larger energy compared with high frequency was generated. Therefore, the removal efficiency at low frequency was higher than at high frequency. However the input energy has to be considered when the process is applied. The statistical tests from a factorial experiment shows that the application of ultrasound and mechanical mixing are the most important factor for design of an ultrasonic soil washing process. The lab-scale experiments are required to get the optimal condition of ultrasound and mechanical mixing for application of ultrasonic soil washing process.

An Integrated Navigation System Combining INS and Ultrasonic-Speedometer to Overcome GPS-denied Area (GPS 음영 지역 극복을 위한 INS/초음파 속도계 결합 항법 시스템 설계)

  • Choi, Bu-Sung;Yoo, Won-Jae;Kim, La-Woo;Lee, Yu-Dam;Lee, Hyung-Keun
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.3
    • /
    • pp.228-236
    • /
    • 2019
  • Recently, multi-sensor integration techniques have been actively studied to obtain reliable and accurate navigation solution in GPS (Global Positioning System)-denied harsh environments such as urban canyons, tunnels, and underground roads. In this paper, we propose a low-cost ultrasonic-speedometer utilizing the characteristics of the ultrasonic propagation. An efficient integrated INS (inertial navigation system)/ultrasonic-speedometer navigation system is also proposed to improve the accuracy of positioning in GPS-denied environments. To evaluate the proposed system, car experiments with field-collected measurements were performed. By the experiment results, it was confirmed that the proposed INS/ultrasonic-speedometer system bounds the positioning error growth effectively even though GPS signal is blocked more than 10 seconds and a low-cost MEMS IMU (micro electro mechanical systems inertial measurement unit) is utilized.

The Vibration Characteristic Improvement by Mode Variation of Ring Type Ultrasonic Motor (리형 초음파모터의 모드가변에 따른 진동특성 개선)

  • 윤신용;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], know the fact that the vibration displacement at 0.5[mm] is an high value too. From such analysis result, this paper was manufactured the ultrasonic motor of outer diameter 50[mm], inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHz]. Then, a propriety of this paper was established the result almost similar to though comparison, investigation of simulation and experiment result.

Experimental Studies on Ultrasonic Guided Waves for the On-Line Inspection of Structural Integrity of Nuclear Power Plants (원전 기기 건전성의 온라인 검사를 위한 유도 초음파의 실험적 연구)

  • Eom, Heung-Seop;Kim, Jae-Hee;Song, Sung-Jin;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • Deployment of an advanced on-line monitoring of the component integrity offers a prospect of improved performance, enhanced safety, and reduced overall cost for nuclear power plants. Ultrasonic guided waves have been known as one of the promising techniques that could be utilized for on-line monitoring. The present work is aimed at developing a new method for on-line monitoring of the pipes during the operation period of nuclear power plants. For this purpose, the steam generator (S/G) tube was selected as an object of tile experiment. Dispersion corves and the incident angles corresponding to the specific modes were calculated for the S/G tube. The modes of guided waves were identified by the time-frequency diagrams obtained by the short time Fourier transform. It was experimentally confirmed that there was no mode conversion when the ultrasonic guided waves passed over the curved region of the S/G tube. An optimum mode of guided wave for the S/G tube was suggested and verified by the experiment.

Effect of Feedrate and Specimen Shape on Cutting Force and Surface Roughness of Ultrasonic Dental Surgical Instrument (치과용 초음파 수술기의 이송속도 및 시편형상이 절삭반력과 표면거칠기에 미치는 영향)

  • Sang Ho Kim;Seung Han Yang;Joong Ho Lee;Jong Kyun Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.109-117
    • /
    • 2023
  • In this study, the effect of the shape of the specimen and the feedrate of the dental ultrasonic surgical instrument on the cutting force and surface roughness of the specimen is analyzed. Experimental specimens were made of SAWBONES artificial bone materials in square and spherical specimens. In addition, the cutting feedrate of the surgical instrument was controlled through the developed moving system. The cutting force generated when cutting the specimen was measured through a force sensor. After the experiment, the cutting surface of the specimen was observed through a three-dimensional optical microscope and the surface roughness was measured. Through one-way ANOVA, the effect of each specimen shape and feed rate on surface roughness was analyzed. As a result of the experiment, the cutting force increased proportionally in the initial feed rate increase stage, but the increase in cutting force decreased as the feed rate continued to increase. Also, the cutting force showed a difference according to the shape of the specimen. The spherical specimen with a relatively small cutting surface area had less cutting force than the square specimen. However, as a result of one-way ANOVA, it was found that the specimen shape and feed rate did not affect the surface roughness. In future studies, it is expected to be used for comparative analysis of ultrasonic surgical instruments and correlation analysis between cutting factors.

The Development of Ultrasonic Transducer for Measurement of Urine Volume in Incontinence Preventive System (뇨실금 방지 시스템에서의 뇨량 측정을 위한 초음파 변환기의 개발)

  • Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.35-42
    • /
    • 2005
  • In this study, we designed and developed an ultrasonic transducer which can measure urine volume based on the estimation of distance between the interior-wall and posterior-wall of bladder. Measurement of urine volume is a way to help patients with urinary incontinence by detecting the amount of urine before the urine is released from the bladder. With the results of this experiment, we can measure the urine volume more accurately and also develop an incontinence preventive system. This study can help patients with urinary incontinence and enuresis to live longer, healthier lives.