• 제목/요약/키워드: Ultrasonic Attenuation Coefficient

검색결과 84건 처리시간 0.045초

Ultrasonic Phase Velocity and Attenuation Coefficient Predicted by Biot's Theory and the MBA Model in Cancellous Bone

  • Lee Kang Il;Yoon Suk Wang
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 추계학술발표대회논문집 제23권 2호
    • /
    • pp.183-186
    • /
    • 2004
  • Biot's theory and a modified Biot-Attenborough (MBA) model are applied to predict the dependences of acoustic characteristics on frequency and porosity in cancellous bone. The phase velocity and the attenuation coefficient predicted by both theories are compared with previous in vitro experimental measurements in terms of the mixed, the fast, and the slow waves. Biot's theory successfully predicts the dependences of phase velocity on frequency and porosity in cancellous bone, whereas a significant discrepancy is observed between predicted and measured attenuation coefficients. The MBA model is consistent with reported measurements for both dependences of phase velocity and attenuation coefficient on frequency and porosity. Based on the theoretical predictions from the MBA model, it is suggested that the attenuation coefficient of the mixed wave is dominated by the fast wave in the low-porosity region while it is dominated by the slow wave in the high-porosity region. This provides a qualitative explanation for the nonlinear relationship of attenuation of the mixed wave with porosity in cancellous bone.

  • PDF

열재현에 의한 SS300 및 STS304의 기계적 성질 및 초음파 특성 (Mechanical Properties and Ultrasonic Characteristic of SS400 and STS304 by Simulated Heats)

  • 정정환;안석환;박인덕;남기우
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.127-132
    • /
    • 2003
  • In a today industry, the welding is doing a many portion in structure manufacture. This study is simulated heat of heat-effected zone and researched a mechanical properties and ultrasonic characteristic in used the SS400 and the STS304. As the result mechanical properties of steel that become drawing decreased because of remaining stress by strain gardening according as simulated heat temperature rises, but according as temperature rises in material that do simulated heat after have done annealing, mechanical propensity was improved. The velocity and attenuation become different by effect of remaining stress than effect of material internal microstructure in ultrasonic wave test. In the case of STS304, there was change in mechanical properties by effect that is by strain hardening, but there was no change in material that simulated heat after annealing. When become drawing in ultrasonic waves test, according as simulated heat temperatures rise, change of attenuation coefficient is looked, but material that simulated heat after annealing was no change almost both the volocity and attenuation.

  • PDF

초음파에 의한 압력용기의 연취성천이온도 평가 (Evaluation of fracture Appearance Transition Temperature to Pressure Vessel by Ultrasonics)

  • 남영현
    • 비파괴검사학회지
    • /
    • 제20권5호
    • /
    • pp.373-380
    • /
    • 2000
  • 파괴적인 방법으로 재료나 설비의 기계적 성질을 평가하기 위해서는 많은 경비와 시간이 소요되므로 비파괴적인 방법을 이용한 재료의 기계적 성질 평가가 주목을 받고 있다. 본 논문에서는 초음파 특성을 이용하여 열처리 온도와 조건에 따른 기계적 성질 변화를 평가하였다. 초음파의 감쇠계수는 열처리 온도가 높을수록 결정립의 크기가 커지므로 증가하였다. 초음파의 감쇠계수는 열처리(담금질, 템퍼링, 용접후열처리)가 진행됨에 따라 감소하였다. 초음파 속도는 담금질과 템퍼링/PWHT한 시편에서 40 m/s의 차이를 보이고 있었다. 감쇠계수와 인성과의 상관성은 매우 좋으며 이러한 상관관계는 단조한 압력용기의 비파괴 평가에 이용할 수 있으며, 더욱이 현장 적용에 효율적으로 응용할 수 있을 것이다.

  • PDF

자기애자 캡의 금구-시멘트 계면 건전성 평가를 위한 초음파법 활용에 대한 연구 (A Study on the Application of Ultrasonic Testing for The Interface Integrity Evaluation between Iron and Cement of Porcelain Insulator Cap)

  • 윤영근;최인혁;손주암;오태근
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.58-65
    • /
    • 2018
  • The life span of the porcelain insulator was made to be 30 years, but currently many of the 154kV NGK porcelain insulators using in Korea are found to have passed the production life. Accidents caused by aged mechanical breakdown can lead to disruption of power supply in some areas, large economic losses, and casualties. Therefore, ultrasonic method, which is one of the non - destructive test methods, is applied as a method for evaluating the integrity of porcelain insulators. In this study, the experiment on the interface of cap was conducted and the difference between the energy difference and the attenuation coefficient of the reflected wave was derived according to the interface state of the steel - cement. The results of this study are expected to be used as the basic data of the ultrasonic testing to evaluate the interface condition of the porcelain insulator cap.

초음파를 이용한 중회귀분석법에 의한 콘크리트의 압축강도추정 (Estimate of Compressive Strength for Concrete using Ultrasonics by Multiple Regression Analysis Method)

  • 박익근;한응교;김완규
    • 비파괴검사학회지
    • /
    • 제11권2호
    • /
    • pp.22-31
    • /
    • 1991
  • Various types of ultrasonic techniques have been used for the estimation of compressive strength of concrete structures. However, conventional ultrasonic velocity method using only longitudial wave cannot be determined the compressive strength of concrete structures with accuracy. In this paper, by using the introduction of multiple parameter, e. g. velocity of shear wave, velocity of longitudinal wave, attenuation coefficient of shear wave, attenuation coefficient of longitudinal wave, combination condition, age and preservation method, multiple regression analysis method was applied to the determination of compressive strength of concrete structures. The experimental results show that velocity of shear wave can be estimated compressive strength of concrete with more accuracy compared with the velocity of longitudinal wave, accuracy of estimated error range of compressive strength of concrete structures can be enhanced within the range of ${\pm}$10% approximately.

  • PDF

이종마찰용접 강봉재의 기계적특성과 비파괴 평가 (The Mechanical Properties and the Nondestructive Evaluation of Dissimilar Friction Welded Steel Bars)

  • 정원택;공유식;김선진
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.77-82
    • /
    • 2006
  • In this study, dissimilar friction welding were produced using 15mm diameter solid bar in chrome molybedenum steel(SCM440) to carbon steel(S45C) to investigate their mechanical properties and the relationship between the weld parameters and the nondestructive coefficients, such as AE counts and ultrasonic attenuation coefficient. The main friction welding parameters were selected to endure good quality welds on the basis of visual examination, tensile tests, Vickers hardness surveys of the bond of area and heat affected zone. The specimens were tested as-welded and post weld heat treated(PWHT). The tensile strength of the friction welded steel bars was increased up to 100% of the S45C base metal under the condition of all heating time. The ductility of PWHT specimens is higher than as-welded.

  • PDF

압전형 초음파 Transducer의 내부 손실이 그 성능에 미치는 영향 (The Effects of the Internal Losses of a Piezoelectric Ultrasonic Transducer on Its Performances)

  • 이종현;이병호;박송배
    • 대한전자공학회논문지
    • /
    • 제23권4호
    • /
    • pp.515-521
    • /
    • 1986
  • Performances of a piezoelectric ultrasonic transducer are analyzed considering the internal losses of a piezoleelctric material and fabricated layers. The KLM-model is adopted for the equivalent circuit of a piezoelectric resonator, and the attenuation coefficient is introduced to represent the internal losses of the transducer. The attenuation coefficient of a piezoelectric resonator is inversely proportional to the maximum value of the input electrical resistance, and is confirmed to be an efficient parameter for the analysis of the considerable lossy piezo-electric resonator operating in a thickness mode. Also, the experimentla RTII is obtained by pulse-echo method. The experimental result is deviated from the predicted one within 3 dB over the 20dB frequency bandwidth.

  • PDF

Digital Spectrum 분석방법을 이용한 조직특성 변수에 관한 연구 (Ultrasonic Tissue Characterization by Digital Spectrum Analysis Technique)

  • 곽철은;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.55-62
    • /
    • 1984
  • A digital spectrum analysis technique was used to estimate the tissue characteristic parameters (transmission velocity and attenuation coefficient) in the phantom study and the human liver's ultrasound scanning. The soft tissue equivalent phantom was made with the combination materials of agar, water, powdered graphite, and n-propyl alcohol. In the human study, twenty five normal subjects and three patients with liver diseases were studied using the ultrasonic reflection signals and the spectrum analysis method The following results were obtained; 1. The soft tissue-equivalent materical could be produced with various acoustic parameters by changing the composition amount of the powdered graphite and n-propyl alcohol. 2. Attenuation coefficients of normal human liver tissue were estimated to be 0. 36 dB/cm MHz$\pm$0.11. In patients with liver disese, tile attenuation coefficients were shown to be different from the above normal values.

  • PDF

초음파의 파형 해석에 의한 고감쇠 재료의 평가 (Evaluation of High Attenuation Material Using Utrasonic Wave Analysis)

  • 남영현
    • 비파괴검사학회지
    • /
    • 제15권2호
    • /
    • pp.364-370
    • /
    • 1995
  • 본 논문은 초음파법을 이용하여 소결 재료의 비파괴적인 평가 방법을 확립하는데 목적을 두고 있다. 소결 재료의 밀도는 소결체로 제작되는 동안 금형과 분말사이의 마찰 때문에 부분적으로 불균질한 분포를 가지고 있으며 이 불균질성은 에너지 감쇠 계수 및 초음파 반사 에코의 주파수 스펙트럼에 있어 중심 주파수의 변화량에 의해 조사되었다. 초음파의 속도, 탄성계수, 포와송 비는 소결 재료의 밀도와 비례 관계에 있었으며 저면 반사파의 중심 주파수는 초음파의 전파 거리의 증가 및 밀도의 감소에 따라 저주파수 쪽으로 이동하였으나 에너지 감쇠 계수는 밀도의 증가에 따라 감소하고 있었다. 본 논문에서는 반사파의 주파수 스펙트럼에 있어 중심 주파수의 변화가 소결 재료의 비파괴적인 평가 방법으로써의 가능성을 보여주고 있다.

  • PDF

상용 MC Nylon계 고분자 재료에서 초음파 특성의 온도 및 주파수 의존성 (Temperature and Frequency Dependences of Ultrasonic Properties in Commercial MC Nylon Polymers)

  • 김명덕;김용태;이강일
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.509-517
    • /
    • 2012
  • 본 연구에서는 상용화된 monomer-cast nylon (MC nylon)계 고분자 재료로 만든 6종류의 시편에 대하여 감쇠계수 및 위상속도와 같은 초음파 특성의 온도 및 주파수 의존성을 조사하였다. 시편의 초음파 특성은 수중에서 2 MHz부터 8 MHz까지의 광대역 주파수 범위에 대하여 펄스투과법을 이용하여 측정하였다. 수온은 $10^{\circ}C$부터 $60^{\circ}C$까지 $10^{\circ}C$ 간격으로 변화시켰다. 측정에 사용된 모든 시편에서 감쇠계수는 주파수가 증가함에 따라 증가하였으며, 주파수의 지수 의존성 n이 선형 (n=1)에서 약간 벗어난 1.16부터 1.44이내의 값을 가졌다. 위상속도는 $60^{\circ}C$에서 ivory 시편을 제외한 모든 경우에 대하여 주파수가 증가함에 따라 감소하는 음의 분산 특성을 나타냈다. 주파수에 의존하는 위상속도는 모든 시편에서 온도가 증가함에 따라 감소하는 특성을 나타내었다.