• Title/Summary/Keyword: Ultra-high

Search Result 3,386, Processing Time 0.031 seconds

A Study on the Flexural Adhesion Performance of Repair Section of Polymer Cement Composites by Crack Depth (균열깊이에 따른 폴리머 시멘트 복합체 보수 단면의 휨접착성능에 관한 연구)

  • Kim, Sang-Hyeon;Park, Dong-Yeop;Lee, Chang-Min;Jo, Young-Kug
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.181-182
    • /
    • 2023
  • This study is a study on the flexural adhesion performance of polymer cement composites(PCCs) repair section according to the crack depth, and the flexural adhesion strength was obtained through a flexural strength test of cement mortar that was filled into cracks and repaired to a certain thickness using PCCs made of ultra high-early strength cement and polymer dispersion of EVA. As a result of the study, the flexural adhesion performance according to the crack width and crack depth was expected to decrease the flexural adhesion strength as the crack depth increased at the crack width 3.0mm, but the crack width 2.0mm and 1.5mm did not show any tendency according to the crack depth. In addition, even in the final destruction, the fact that the cracks and bottoms filled with PCCs were not cut or dropped proves that PCCs have excellent adhesion and rich toughness.

  • PDF

Selective Atomic Layer Deposition of Co Thin Films Using Co(EtCp)2 Precursor (Co(EtCp)2프리커서를 사용한 Co 박막의 선택적 원자층 증착)

  • Sujeong Kim;Yong Tae Kim;Jaeyeong Heo
    • Korean Journal of Materials Research
    • /
    • v.34 no.3
    • /
    • pp.163-169
    • /
    • 2024
  • As the limitations of Moore's Law become evident, there has been growing interest in advanced packaging technologies. Among various 3D packaging techniques, Cu-SiO2 hybrid bonding has gained attention in heterogeneous devices. However, certain issues, such as its high-temperature processing conditions and copper oxidation, can affect electrical properties and mechanical reliability. Therefore, we studied depositing only a heterometal on top of the Cu in Cu-SiO2 composite substrates to prevent copper surface oxidation and to lower bonding process temperature. The heterometal needs to be deposited as an ultra-thin layer of less than 10 nm, for copper diffusion. We established the process conditions for depositing a Co film using a Co(EtCp)2 precursor and utilizing plasma-enhanced atomic layer deposition (PEALD), which allows for precise atomic level thickness control. In addition, we attempted to use a growth inhibitor by growing a self-assembled monolayer (SAM) material, octadecyltrichlorosilane (ODTS), on a SiO2 substrate to selectively suppress the growth of Co film. We compared the growth behavior of the Co film under various PEALD process conditions and examined their selectivity based on the ODTS growth time.

The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up

  • Bum-Jin Shim;Sung-Jin Park;Chan Ho Park
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.115-121
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA). The Kaplan-Meier survivorship was also evaluated. Results: Linear wear and volumetric wear rates were 0.11±0.47 mm/year and 32.75±24.50 mm3/year, respectively. Nine revisions were performed during the follow-up period because of cup or stem loosening. The Kaplan-Meier survival rate, using cup revision or total revision total hip arthroplasty (THA) as the endpoint of analysis, was 93.7% at 15 years and 73.6% at 20 years. Conclusion: Because all revisions were performed between 15 and 20 years in our study, surgeons should pay greater attention to patients who underwent THA with ceramic-on-polyethylene bearing from 15 years postoperatively. Contemporary alumina ceramic on highly cross-linked polyethylene could certainly be a good alternative bearing couple providing better longevity.

Strategies for Renal Protection in Cardiovascular Interventions

  • Ziad A. Ali;Javier Escaned;Dariusz Dudek;Jai Radhakrishnan;Keyvan Karimi Galougahi
    • Korean Circulation Journal
    • /
    • v.52 no.7
    • /
    • pp.485-495
    • /
    • 2022
  • Coronary artery disease is highly prevalent in chronic kidney disease (CKD) and is a risk factor for contrast-associated acute kidney injury (CA-AKI), a complication of cardiovascular procedures that require contrast administration (e.g., coronary angiography, percutaneous coronary intervention [PCI]). CA-AKI has a major impact on morbidity, mortality, and healthcare resource utilization. The incidence of CA-AKI is particularly high in patients with pre-existing CKD, advanced age and comorbidities that increase the likelihood of CKD. The focus of the present review is to provide a brief overview on the assessment of the risk for and prevention of CA-AKI in patients undergoing angiography and PCI, including recognition of the important patient- and procedure-related factors that may contribute to CA-AKI. Preventive and treatment strategies, the mainstay of which is volume repletion by normal saline, are briefly discussed. The main focus of the review is placed on technical details of contrast minimization techniques, including ultra-low contrast angiography and zerocontrast PCI. Operator competence in such techniques is important to ensure that procedural challenges in patients with CKD, like vessel calcification, multivessel disease and complex anatomical subsets, are effectively addressed by PCI while minimizing the risk of CA-AKI.

Cytomegalovirus retinitis with panretinal occlusive vasculopathy concealed by hypertensive uveitis: a case report

  • Seongyong Jeong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.4
    • /
    • pp.300-305
    • /
    • 2024
  • Cytomegalovirus (CMV) retinitis is a rare disease, and overlapping manifestations involving the anterior segment are extremely uncommon. We report a patient who initially presented with persistent corneal edema and was later diagnosed with CMV retinitis. A 72-year-old man with uncontrolled intraocular pressure (IOP) in his right eye visited a tertiary hospital. At initial presentation, the IOP was 36 mmHg and the fundus was not clear due to corneal edema. Spectral domain optical coherence tomography revealed paracentral acute middle maculopathy (PAMM). Panretinal obstructive vasculopathy was observed on ultra-widefield fluorescein angiography. Three weeks later, trabeculectomy was performed to resolve the persistently high IOP. Once corneal edema improved, a white patch-like peripheral lesion and silver wire-like retinal vasculature were observed. Polymerase chain reaction of the aqueous humor was positive for CMV. Oral valganciclovir and intravitreal ganciclovir were administered as antiviral therapies. Despite treatment for 4 months, the final visual acuity was no light perception, with persistent corneal edema and neovascularization of the iris. We describe a rare case of the simultaneous occurrence of hypertensive uveitis and CMV retinitis. The presence of PAMM could be an initial identifiable sign of CMV retinitis, even in the presence of media opacity.

Terahertz Light Source Using Spin Angular Momentum: Spintronic Terahertz Emission (스핀 각 운동량을 이용한 테라헤르츠파 광원: 스핀트로닉 테라헤르츠 발생)

  • Kyusup Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.5
    • /
    • pp.218-227
    • /
    • 2024
  • The tabletop-scale terahertz (THz) light sources using femtosecond laser pulses are primarily based on spatiotemporal changes in electron charge. This review introduces a new scheme where the spin angular momentum of electrons contributes to THz wave generation. By focusing on laser-induced spin current generation in ferromagnets, we review the outstanding characteristics observed in nanometric ferromagnetic/nonmagnetic thin films, including high power, ultra-broadband, and polarization tunability. Additionally, research on various application technologies is introduced, including the development of devices combining semiconductors, large-area THz devices, and flexible THz devices, all based on nanoscale thin films. Through this, the principle of spintronic THz emission can be understood, contributing the advancement of various application studies utilizing electron spin as a next-generation THz optical device.

A study of Development of Transmission Systems for Terrestrial Single Channel Fixed 4K UHD & Mobile HD Convergence Broadcasting by Employing FEF (Future Extension Frame) Multiplexing Technique (FEF (Future Extension Frame) 다중화 기법을 이용한 지상파 단일 채널 고정 4K UHD & 이동 HD 융합방송 전송시스템 개발에 관한 연구)

  • Oh, JongGyu;Won, YongJu;Lee, JinSeop;Kim, JoonTae
    • Journal of Broadcast Engineering
    • /
    • v.20 no.2
    • /
    • pp.310-339
    • /
    • 2015
  • In this paper, the possibility of a terrestrial fixed 4K UHD (Ultra High Definition) and mobile HD (High Definition) convergence broadcasting service through a single channel employing the FEF (Future Extension Frame) multiplexing technique in DVB (Digital Video Broadcasting)-T2 (Second Generation Terrestrial) systems is examined. The performance of such a service is also investigated. FEF multiplexing technology can be used to adjust the FFT (fast Fourier transform) and CP (cyclic prefix) size for each layer, whereas M-PLP (Multiple-Physical Layer Pipe) multiplexing technology in DVB-T2 systems cannot. The convergence broadcasting service scenario, which can provide fixed 4K UHD and mobile HD broadcasting through a single terrestrial channel, is described, and transmission requirements of the SHVC (Scalable High Efficiency Video Coding) technique are predicted. A convergence broadcasting transmission system structure is described by employing FEF and transmission technologies in DVB-T2 systems. Optimized transmission parameters are drawn to transmit 4K UHD and HD convergence broadcasting by employing a convergence broadcasting transmission structure, and the reception performance of the optimized transmission parameters under AWGN (additive white Gaussian noise), static Brazil-D, and time-varying TU (Typical Urban)-6 channels is examined using computer simulations to find the TOV (threshold of visibility). From the results, for the 6 and 8 MHz bandwidths, reliable reception of both fixed 4K UHD and mobile HD layer data can be achieved under a static fixed and very fast fading multipath channel.

Stud and Puzzle-Strip Shear Connector for Composite Beam of UHPC Deck and Inverted-T Steel Girder (초고성능 콘크리트 바닥판과 역T형 강거더의 합성보를 위한 스터드 및 퍼즐스트립 전단연결재에 관한 연구)

  • Lee, Kyoung-Chan;Joh, Changbin;Choi, Eun-Suk;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.151-157
    • /
    • 2014
  • Since recently developed Ultra-High-Performance-Concrete (UHPC) provides very high strength, stiffness, and durability, many studies have been made on the application of the UHPC to bridge decks. Due to high strength and stiffness of UHPC bridge deck, the structural contribution of top flange of steel girder composite to UHPC deck would be much lower than that of conventional concrete deck. At this point of view, this study proposes a inverted-T shaped steel girder composite to UHPC deck. This girder requires a new type of shear connector because conventional shear connectors are welded on top flange. This study also proposes three different types of shear connectors, and evaluate their ultimate strength via push-out static test. The first one is a stud shear connector welded directly to the web of the girder in the transverse direction. The second one is a puzzle-strip type shear connector developed by the European Commission, and the last one is the combination of the stud and the puzzle-strip shear connectors. Experimental results showed that the ultimate strength of the transverse stud was 26% larger than that given in the AASHTO LRFD Bridge Design Specifications, but a splitting crack observed in the UHPC deck was so severe that another measure needs to be developed to prevent the splitting crack. The ultimate strength of the puzzle-strip specimen was 40% larger than that evaluated by the equation of European Commission. The specimens combined with stud and puzzle-strip shear connectors provided less strength than arithmetical sum of those. Based on the experimental observations, there appears to be no advantage of combining transverse stud and puzzle-strip shear connectors.

Estimation of High Resolution Sea Surface Salinity Using Multi Satellite Data and Machine Learning (다종 위성자료와 기계학습을 이용한 고해상도 표층 염분 추정)

  • Sung, Taejun;Sim, Seongmun;Jang, Eunna;Im, Jungho
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.747-763
    • /
    • 2022
  • Ocean salinity affects ocean circulation on a global scale and low salinity water around coastal areas often has an impact on aquaculture and fisheries. Microwave satellite sensors (e.g., Soil Moisture Active Passive [SMAP]) have provided sea surface salinity (SSS) based on the dielectric characteristics of water associated with SSS and sea surface temperature (SST). In this study, a Light Gradient Boosting Machine (LGBM)-based model for generating high resolution SSS from Geostationary Ocean Color Imager (GOCI) data was proposed, having machine learning-based improved SMAP SSS by Jang et al. (2022) as reference data (SMAP SSS (Jang)). Three schemes with different input variables were tested, and scheme 3 with all variables including Multi-scale Ultra-high Resolution SST yielded the best performance (coefficient of determination = 0.60, root mean square error = 0.91 psu). The proposed LGBM-based GOCI SSS had a similar spatiotemporal pattern with SMAP SSS (Jang), with much higher spatial resolution even in coastal areas, where SMAP SSS (Jang) was not available. In addition, when tested for the great flood occurred in Southern China in August 2020, GOCI SSS well simulated the spatial and temporal change of Changjiang Diluted Water. This research provided a potential that optical satellite data can be used to generate high resolution SSS associated with the improved microwave-based SSS especially in coastal areas.

Benchmark Test Study of Localized Digital Streamer System (국산화 디지털 스트리머 시스템의 벤치마크 테스트 연구)

  • Jungkyun Shin;Jiho Ha;Gabseok Seo;Young-Jun Kim;Nyeonkeon Kang;Jounggyu Choi;Dongwoo Cho;Hanhui Lee;Seong-Pil Kim
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.2
    • /
    • pp.52-61
    • /
    • 2023
  • The use of ultra-high-resolution (UHR) seismic surveys to preceisly characterize coastal and shallow structures have increased recently. UHR surveys derive a spatial resolution of 3.125 m using a high-frequency source (80 Hz to 1 kHz). A digital streamer system is an essential module for acquiring high-quality UHR seismic data. Localization studies have focused on reducing purchase costs and decreasing maintenance periods. Basic performance verification and application tests of the developed streamer have been successfully carried out; however, a comparative analysis with the existing benchmark model was not conducted. In this study, we characterized data obtained by using a developed streamer and a benchmark model simultaneously. Tamhae 2 and auxiliary equipment of the Korea Institute of Geoscience and Mineral Resources were used to acquire 2D seismic data, which were analyzed from different perspectives. The data obtained using the developed streamer differed in sensitivity from that obtained using benchmark model by frequency band.However, both type of data had a very high level of similarity in the range corresponding to the central frequency band of the seismic source. However, in the low frequency band below 60 Hz, data obtained using the developed streamer showed a lower signal-to-noise ratio than that obtained using the benchmark model.This lower ratio can hinder the quality in data acquisition using low-frequency sound sources such as cluster air guns. Three causes for this difference were, and streamers developed in future will attempt to reflect on these improvements.