• Title/Summary/Keyword: Ultra sound

Search Result 92, Processing Time 0.03 seconds

Novel Recycling Technology of Ultra-fine Fibrous Materials

  • Kim, Seong-Hun;Oh, Kyung-Wha;Lee, Shin-Kyung
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.209-209
    • /
    • 2006
  • Ultra-fine fibers are spun by expensive fiber spinning technology using special spinnerets. Ultra-fine fibrous materials have attracted considerable attentions because of their potential applications as high performance wiping cloths, water absorbent sound proofing materials and moisture transfer sporting good. However, production expense of ultra-fine fibers is 5 to 7 times higher than general textile materials. The objective of this research is to develop cost-effective recycling process to produce multi-functional ultra-fine fibrous material in terms of the development of garnetting and carding machines for ultra-fine fibrous material waste and scrap. The efficiency of sound absorption for the recycled polyester nonwoven increased with decreasing length and thickness of component fibers, which was attributed to the reduction of air permeability. It is expected that high value and cost-effective textile products are developed using ultra-fine fibrous wastes and that sound proofing material and oil absorbent f

  • PDF

A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis (혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구)

  • 김희원;이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.329-336
    • /
    • 2003
  • Intra-Vascular Ultra-Sound (IVUS) transducers were developed for the application to diagnose coronary diseases. The transducer consists of 32 piezoelectric elements with a front insulation layer and a polymeric acoustic backing layer on a hollow alumina tube. The optimal geometrical structure of the transducer was designed through theoretical analysis of radiation patterns of the transducer. Samples of the IVUS transducers of the diameter of 3㎜ were fabricated to illustrate the design scheme. For the piezoelectric elements, 2-2 mode piezocomposite materials were employed. Experimental performance of the transducers showed good agreement with the design results, which verified feasibility of the transducer for IVUS applications.

Effects on Electrophysiologic Responses to the Transcutaneous Electrical Nerve Stimulation and Ultra Sound (경피신경전기자극과 초음파가 전기생리학적 반응에 미치는 영향)

  • Baek Su-Jeong;Lee Mi-Ae;Kim Jin-Sang;Choi Jin-ho
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.49-56
    • /
    • 2000
  • The purpose of this study was to investigate the influnce of afferent stimuli, transcutaneous electrical nerve stimulation and ultra sound, on the electrdiagnostic study of normal subjects. Electrodiagnostic study was performed before and after the application of afferent stimulation of the right popliteal fossa on 18 healthy female volunteers. After the transcutaneous electrical nerve stimulation, there is no significantly change of latencies and amplitudes of SEP, H-reflex, peroneal nerve F-wave, and sensory nerve conduction. After the ultra sound, there is no significantly change of latencies and amplitudes of SEP, H-reflex, peroneal nerve F-wave, and sensory nerve conduction. Tibial nope F-wave and motor nerve shows prolonged latency after TENS and US (p<0.01). Ultrasound may have a similar mechanism of action compared to transcutaneous electrical nerve stimulation by having localized inhibitory effects of the peripheral nerve. However, further investigation is needed to assess their mechanism of action and the precise relevance of stimulation modality.

  • PDF

Development of sound level meter provided with ultra-low SPL measuring function -Creation and evaluation of super-silent spaces-

  • Kawakami, Fukushi;Terazono, Shinichi;Lee, Ho-Gi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.760-761
    • /
    • 2010
  • As is widely known, SPL measurement using sound level meter (SLM) is limited to higher than 30 dBA, because of the self-noise n(x) of condenser microphone (CM). The authors confirmed n(x) is composed of 3 kinds, each of which is stable enough under the condition -20 ~ +50 deg C to eliminate the influence of n(x) by subtracting its energy from the squared input signal in the integration process, as well as to develop new type of SLM with ultra-low SPL measuring function. This is so-called "0-dB SLM" since it enables to measure SPL down to around 0 dB-SPL. The RMS of n(x) is acquired and stored in ROM in advance, by placing CM in the supersilent space or by using dummy microphone with equivalent capacitance before the actual measurements.

  • PDF

A Study on System of Subbottom Searched Using Ultra Sonic (초음파를 이용한 저질판독 시스템에 관한 연구)

  • 김재갑;김원중;황두진
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.383-387
    • /
    • 2001
  • The sea flower begins at the water-sediment Interface. In the ocean basins, the sound velocity of the sediments at the interface vary from a few percent less than the sound speed in water just above the interface to somewhat greater. Marine sediments are unconsolidated; that is, the particles are not cemented of fused together. Samples feel like mud, muddy sand, sand, and so on. With the theoretical knowledge, the systematic research on the searching capability of Ultra Sonic Signal will be continued to identify the influence against the sea water subject. In this research, signal will be analyzed according to the influence range, power and sensitiveness of Ultra Sonic Generator. In addition, the radius of Ultra Sonic Signal will be included. The experimental field work will be executed at Nockdong, Pulkyo and other places well known as a habitat of Pan Shell.

  • PDF

Development of Sound Frequency Analyser using an Ultra-Low Power MCU (초저전력 Micro Controller Unit(MCU)를 활용한 소리 주파수 분석기 개발)

  • Choi, Jae-Hoon;Chung, Yong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.403-410
    • /
    • 2016
  • Materials made of metals have their own manifest resonant frequencies. Using this property, the quality test of products from the factory can be performed. An impact is applied to the product and the frequencies of the sound and/or vibration are measured using high-end equipments. They use a general purpose computer or a DSP(: Digital Signal Processor)-based stand-alone system which is usually too large in-size to carry and expensive to build. In this paper, we introduce a system that is developed based on a MSP430 MCU(:Micro-Controller Unit) from TI(: Texas Instruments). The ultra-low power MSP430 MCUs make it possible to make a frequency analyzer in a very small size without the need of using a large-size battery. The proposed system can be used in situations where the frequency analyzer should be carried easily with an investigator and should be built at low cost sacrificing some accuracy. We implemented the system using a launchpad supplied by TI and could confirm that the proposed system could identify with a high-accuracy the frequencies of various artificial and natural sounds.

'Super Hi-Vision'-an ultra-high definition television-and its human factors

  • Sugawara, M.;Masaoka, K.;Emoto, M.;Nojiri, Y.;Okano, F.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.81-85
    • /
    • 2006
  • The ultra-high definition TV system nicknamed "Super Hi-Vision" is a television system with 4000-scanning-line video and 22.2 multichannel sound. NHK has been developing it with the aim of creating a broadcasting system conveying a strong sensation of presence. We believe that it is important to design the system by taking into account human factors such as human visual system characteristics. This paper describes the psychological and physiological experiments on the visual effects of "Super Hi-Vision".

  • PDF

Development of the Ultra-Silence Refrigerator with Considering Consumer's Hearing (소비자 청감을 고려한 초 저소음 냉장고 개발)

  • Joo, Jae-Man;Lee, Jea-Won;Lee, Jin-Woo;Jeoung, Jeoung-Kyo;Kim, Yong-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.435-438
    • /
    • 2005
  • Until now, a home appliance mostly has revealed physical quantities created by the standpoint of engineers, by using the A-weighted sound pressure level and the sound power. It is, however, obviously impossible to characterize a complex sound with a single number. Many parameters must be considered. In addition to loudness, we must take into account frequency and amplitude variation over time, spectral balance, tonality, and many other attributes. Thus, in this research, the general tendency of consumer psychology was investigated for the refrigerator's sound. The noise from the refrigerator was evaluated by not only the simple sound pressure levels but also the consumer's sense of hearing. And also, in order to improve the quality of sound through the design change, the consumer's evaluation was analysed and related to the engineering quantities. With the several design changes, finally the most silence refrigerator in the world was developed with considering the consumer's hearing of sense.

  • PDF

Study on the Fabrication of a Large Steel Ingot with the Ultra Clean and Low Hot Top Ratio (저압탕 고청정 대형 잉고트 제조 연구)

  • Oh, S.H.;Lee, D.H.;Kim, N.S.;NamKung, J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.91-93
    • /
    • 2009
  • A large steel ingot needs to be larger and larger in size and an ultra high clean, no defect in quality with a low hot top ratio for the resent heavy industry. The demands are very difficult to achieve simultaneously because of their contradictive effect to each other in results. In this study, 30ton steel ingot was cast in a foundry with an optimized design parameter of cast mold and cast process conditions for the low hot top ratio, 12%. The cast ingot was analyzed in macro defect, segregations, and cleanness. No macro defect was founded in central surface of the ingot. The degree of segregation and cleanness are in the controlled range with a sound quality.

  • PDF