• 제목/요약/키워드: Ultra sonic treatment

검색결과 14건 처리시간 0.023초

Study on Sonic Influence upon Crop Yield and Insect Pest Damage

  • Yuchuan Qin;Lee, Won-Chu;Park, Young-Cheol
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제3권1호
    • /
    • pp.97-99
    • /
    • 2001
  • Seven vegetables were planted in green houses to compare their yields and damages by insect pests based on three treatments, green music (GM), ultra sonic (US) and control. The vegetable yields of GM treatment were increased by an average of 17.81% than that of control for two years. There was a remarkable statistic difference in the yield between GM and respective controls such as radish, young radish, cucumber, spinach and Brassica oleracea var. acephala. There was no notable yield difference between US and controls for the semen vegetables within two years. The population densities of the insect pests in GM and US treatments were lower than controls. Only a few insect pests of some vegetables in GM and US treatments injured more seriously than in control.

  • PDF

Air-Polisher의 응용법 (Application of Air-Polisher)

  • 김민정
    • 대한심미치과학회지
    • /
    • 제7권1호
    • /
    • pp.72-78
    • /
    • 1998
  • Recently, esthetic dentistry has been developed because beauty is pursued by both dentists and patients. A scope of esthetic treatment has been expanded and the roles of hygienists in dental treatment have also become of importance. Generally, we make use of the ultra-sonic scaler to remove the stains attached to teeth surfaces, but when we utilize the rubber cup and pumice in prophylaxis, this increases the hypersensitivity, patient's anxiety, and chairtime. So, we substitute Air-polishing that increases patient's satisfaction and decreases chairtime for above method, Here, I would like to explain indications and contraindications, advantages and disadvantages, and usages of Air-polilshing briefly.

  • PDF

분산법이 무전해 Ni-CNT 복합도금막 형성에 미치는 영향 (Effect of Dispersion Method on Formation of Electroless Ni-CNT Coatings)

  • 배규식
    • 반도체디스플레이기술학회지
    • /
    • 제13권3호
    • /
    • pp.51-55
    • /
    • 2014
  • Ni-CNT(Carbon Nanotubes) composite coating is often used for the surface treatment of mechanical/electronic devices to improve the properties of the Ni coating. For the Ni-CNT coating, the dispersion of CNT fibers is a critical process. In this study, ultrasonic treatment instead of the conventional ball milling was attempted as a dispersion method for the electroless Ni-CNT coating. SEM-EDX analysis was performed and contact angle, sheet resistance, and micro-hardness were measured. Results showed that the ultrasonic treatment was comparable to the ball milling, as a dispersion method, but the difference was negligible. However, combined ball milling and ultrasonic treatment(double treatment) showed much improved micro-hardness value, above 350Hv(close to the value obtained by the Ni-CNT electroplating). In addition, electroless Ni-CNT(double-treated) coatings formed on the thin Ni film deposited by the electroless plating(double coating) showed better mechanical properties. Thus, double treatment and double coating are suggested as an improved electroless Ni-CNT coating method.

염료감응형 태양전지 광전극의 초음파 열처리를 통한 광전효율 개선에 관한 연구 (A Study of Photo-electric Efficiency Improvement using Ultrasonic and Thermal Treatment on Photo-electrode of DSC)

  • 김희제;김용철;최진영;김호성;이동길;홍지태
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.803-807
    • /
    • 2008
  • A making process of DSC(dye sensitized solar cell) was presented. In general, Photo electrodes of DSC was made by using colloid paste of nano $TiO_2$ and processing of Doctor-blade printing and high temperature sintering for porous structure. These methods lead to cracks on $TiO_2$ surface and ununiform of $TiO_2$ thickness. This phenomenon is one factor that makes low efficiency to cells. After $TiO_2$ printing on TCO glass, a physical vibration was adapted for reducing ununiform of $TiO_2$ thickness. And a thermal treatment at low temperature(under $75^{\circ}C$) was adapted for reducing cracks on $TiO_2$ surface. In this paper, we have designed and manufactured an ultrasonic circuit (100W, frequency and duty variable) and a thermal equipment. Then, we have optimized forcing time, frequency and duty of ultrasonic irradiation and thermal heating for surface treatment of photo-electrode of DSC. In I-V characteristic test of DSC, ultrasonic and thermal treated DSC shows 19% improved its efficiency against monolithic DSC. And it shows stability of light-harvesting from drastically change of light irradiation test.

생산성 향상을 위한 연삭공정의 감시.제어시스템 개발 (Development of Monitoring/Control System for High Productive Grinding System)

  • 정병철;안중환;이상우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 춘계학술대회 논문집
    • /
    • pp.425-428
    • /
    • 1994
  • Non-uniform minute deformation of a cylinderical workpiece resulted from the heat treatment process prior to the grinding makes it diffeclt to control the approaching feedrate of a grinding wheelto a workpiece optimallywithout on-site detection of the grinding states in the plunge grinding. The 4-stage model of the plunge grinding process is proposed according to the state of contact between grinding wheel and workpiece ; precontact, partial contact, entire contact and spark-out. Despite of being scrious to the precision of workpiece finished, the duration of spark-out is determined empirically. The purpose of this research is to develop a monitoring/control system for saving non- production time and setting the optimal spark-out time based on sensor information in the plunge grinding using AE and ultra sonic sensor.

  • PDF

초음파 계측에 의한 2.25Cr-1Mo강의 열화도 평가에 관한 연구 (A Study on the Evaluation of Material Degradation for 2.25Cr-1Mo Steel by Ultrasonic Measurements)

  • 박은수;박익근;김정석
    • 한국공작기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.61-67
    • /
    • 2001
  • The remaining life estimation for the aged component is very important because mechanical properties of the compo-nents are degraded with time of service exposure in high temperature etc. The destructive method is widely used for the estimation of material degradation, but it has a difficulty in preparing specimens from in-service industrial facilities. In order to evaluate the feasibility of ultrasonic evaluation method for properties of high temperature materials, 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at 63$0^{\circ}C$ were evaluated by ultra-sonic measurements investigating the change of velocities and attenuation coefficient. In this results, attenuation coefficient was found to be sensitive to material degradation mainly attributed to the change of grain size and the precipitation of impurities in grain boundaries, but velocity was not for all specimens.

  • PDF

Evaluation of Life Span for Al2O3 Nano Tube Formed by Anodizing with Current Density

  • 이승준;김성종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.148-148
    • /
    • 2017
  • Surface modification is a type of mechanical manipulation skills to achieve extensive aims including corrosion control, exterior appearance, abrasion resistance, electrical insulation and electrical conductivity of substrate materials by generating a protective surface using electrical, physical and chemical treatment on the surface of parts made from metallic materials. Such surface modification includes plating, anodizing, chemical conversion treatment, painting, lining, coating and surface hardening; this study conducted cavitation experiment to assess improvement of durability using anodizing. In order to observe surface characteristics with applied current density, the electrolyte temperature, concentration was maintained at constant condition. To prevent hindrance of stable growth of oxide layer due to local temperature increase during the experiment, stirring was maintained at constant speed. In addition, using galvanostatic method, it was maintained at processing time of 40minutes for 10 to $30mA/cm^2$. The cavitation experiment was carried out with an ultra sonic vibratory apparatus using piezo-electric effect with modified ASTM-G32. The peak-to-peak amplitude was $30{\mu}m$ and the distance between the horn tip and specimen was 1mm. The specimen after the experiment was cleaned in an ultrasonic bath, dried in a vacuum oven for more than 24 hours, and weighed with an electric balance. The surface damage morphology was observed with 3D analysis microscope. As a result of the study, differences were observed surface hardness and anti-cavitation characteristics depending on the development of oxide film with the anodizing process time.

  • PDF

폐 RHDM 촉매의 재생 후 워시코팅에 의한 NOx 저감 효율 (The Efficiency of NOx Reduction by Regeneration and Wash Coating of Spent RHDM Catalyst)

  • 나우진;박해경
    • 한국응용과학기술학회지
    • /
    • 제35권3호
    • /
    • pp.876-885
    • /
    • 2018
  • 폐 RHDM(Residue Hydrodemetallation) 촉매상에 침적된 비활성화 성분인 탄소, 황 을 고온배소 처리하여 제거한 후, 과량 침적되어 있는 바나듐은 초음파 교반기에서 5~15wt% 옥살산 수용액을 이용하여 $50^{\circ}C$, 5분 조건하에 바나듐 추출량을 조절함으로써 NOx 저감을 위한SCR(Selective Catalytic Reduction) 촉매로의 적용 가능성을 확인하고자 하였다. 폐촉매와 단계별 처리된 RHDM 촉매를 대상으로 상압반응기상에서 NOx 저감 효율을 측정하였고, 촉매의 성분분석은 ICP, C & S analyzer 및 XRF를 이용하여 분석하였다. 10wt% 옥살산 수용액으로 바나듐을 침출한 촉매가 가장 안정적이었으며 높은 NOx 저감 효율을 보였다. 이를 메탈폼 형태의 지지체에 워시코팅한 촉매는 상용 SCR 촉매와 동등 수준의 NOx 저감 효율을 나타내었다. 따라서 폐 RHDM 촉매의 처리 조건 조정에 관한 후속 연구를 통하여 각 적용처에 적합한 SCR 촉매로의 이용 가능성은 충분할 것으로 사료된다.

미세기포화 오존과 자외선, 초음파, 과산화수소를 이용한 돈분뇨 슬러리 고도처리 (Advanced Treatment of Piggery Slurry Using Micro Ozone Bubble, UV, Ultra Sonic and Hydroxy Peroxide)

  • 정광화;김재환;곽정훈;정만순;이광희
    • 한국축산시설환경학회지
    • /
    • 제15권3호
    • /
    • pp.209-216
    • /
    • 2009
  • 침전 및 고액분리 후 활성오니 공정 즉 분뇨 오수의 2차 처리공정까지를 거친 돈분뇨슬러리를 대상으로 하여 미세용존 오존 및 초음파와 자외선 그리고 과산화수소 등을 조합하여 적용한 고도처리 시험결과를 요약한 주요결과는 다음과 같다. 1. 돼지분뇨 오수 시료를 대상으로 하여 오존과 UV를 적용하였을 경우 전반적으로 색도와 오염성물질의 농도가 줄어드는 경향이 있었다. 2. 미세용존 오존을 이용하여 오존농도 $52\;g/Nm^3$ 조건에서 색도농도가 각기 다른 시료를 대상으로 하여 30분간 반응시켰을 경우 색도는 각각의 처리구 공히 처리시간의 경과에 따라 감소하는 결과를 보였다. COD를 포함한 오염성 물질의 농도도 처리시간의 경과에 따라 감소하였으며 자외선과 과산화수소 등 유기물질의 분해 및 산화력을 가진 물질의 첨가는 오존처리의 효율을 높이는 역할을 하였다. 3. 오존처리에 의해 처리수 중의 대장균과 살모넬라 수가 감소하였으며 과산화수소를 첨가할 경우 그 감소효과는 더 증가하였다는 경향이 있었다. 오존과 과산화수소수를 병합처리 하였을 경우에는 $7.5{\times}10^\;CFU/mL$ 이었던 살모넬라가 처리 후 10분 만에 10 CFU/L 이하로 낮아졌으며 20분 처리 후에는 오존과 과산화수소수를 병합한 처리구에서는 검출되지 않았다. 이 결과는 과산화수소의 짝염기인 ${HO_2}^-$가 OH 라디칼의 생성을 촉진함으로써 살모넬라 등의 세균감소 효과를 높인것에 기인한 것으로 판단된다.

  • PDF

도말층 존재 유무에 따른 One-step 접착 시스템의 미세인장결합강도 (MICROTENSILE BONDING OF ONE-STEP ADHESIVES TO SHEARED AND NON-SHEARED DENTIN)

  • 송용범;진정희;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.299-309
    • /
    • 2002
  • The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100$^{TM}$) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wet$.$e treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37$^{\circ}C$ distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(mean$\pm$SD) of microtensile test were group 1, 25.69$\pm$4.31MPa; group 2, 40.93$\pm$10.94MPa; group 3, 47.65$\pm$8.85MPa; group 4, 35.98$\pm$9.14MPa; group 5, 39.66$\pm$8.45MPa; group 6, 43.26$\pm$13.01MPa; group 7, 25.07$\pm$4.2MPa;group 8, 30.4$\pm$4.74MPa;group 9, 33.61$\pm$7.88MPa. 2. One-Up Bond F was showed the highest value of 36.98$\pm$9.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p<0.05). 3. All-Bond 2 was showed the highest value of 40.93$\pm$10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p<0.05). 5. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p<0.05).