• 제목/요약/키워드: Ultra low NOx burner

검색결과 2건 처리시간 0.016초

15MW급 부분예혼합 초저 NOx 가스연소기에 관한 실험적 연구 (Experimental Study on 15MW partially premixed Low NOx burner)

  • 권민준;신명철;김세원;이창엽
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.123-125
    • /
    • 2012
  • In this study, combustion characteristics for 20t/h water tube boilers are studied. The burner by applying The fuel staging technology, the air staging technology, the partially premixed technology, the separated flame technology and the flame inner recirculation technology was designed. This study was to determine the combustion characteristics for the three types of burners. It is found that the result of flame temperature measurement is less than $1300^{\circ}C$ at the all flame region. also, emissions of NOx and CO are found to be 15.8 ppm and 18.9 ppm, respectively.

  • PDF

80 kW 초 저 NOx 단일 버너 연소로에서 NOx 감소를 위한 운전특성 연구 (Study on Operating Characteristics for NOx Reduction in Ultra Low NOx Burner Combustion Using 80 kW Furnace)

  • 채태영
    • 청정기술
    • /
    • 제26권3호
    • /
    • pp.211-220
    • /
    • 2020
  • 본 연구는 80 kW급 단일버너 연소로에서 석탄 연소시 초저 NOx 버너 설계인자를 평가하기 위한 실험적 연구이다. 버너 설계 인자인 선회강도, 총 과잉 공기비, 버너 영역 과잉공기비, 1차/2차 산화제 비율, OFA 비율을 변경하여 총 81개 조건을 대상으로 실험을 수행 하였다. 실험 결과, 선회류가 약하면 연소로 출구에서 CO가 증가하고 연소로 내부 온도가 감소하는 것으로 나타났다. 그러나, 선회류가 강하면 NOx가 증가하기 때문에 적절한 선회류 강도를 결정하는 것은 NOx를 줄이는 데 중요한 요소이다. 1차/2차 산화제의 비율 또한 중요한 요소이며, 생성 된 NOx의 양은 산화제의 비율에 따라 달라진다. 2차 산화제의 비율이 증가하면 연소 초기에 NOx 방출량이 증가하고, 측정 된 배출구 NOx가 증가하게 된다. 그러나, 2차 산화제 비율이 감소하면 화염이 길어지고 CO가 증가한다. 본 연구에 사용 된 연소 시스템은 적절한 조건이 만족 될 때 O2 6%를 기준으로 최소 NOx가 82 ppm 생성되는 것으로 확인 되었다. 본 실험에서 대상으로 한 버너는 연소용 공기를 석탄을 이송하는 1차공기 외에 2차공기로 하나의 산화제 유동만 사용하는 방식으로서 추후 3차 및 4차공기로 분할하여 화염형태 및 반응을 세밀하게 제어할 경우 추가적인 NOx 감소가 가능할 것으로 예상된다.