• Title/Summary/Keyword: Ultra high-strength concrete

Search Result 465, Processing Time 0.026 seconds

Analysis Study on The Strength Range of Ultra High Strength Concrete (초고강도 콘크리트의 강도편차 분석연구)

  • Park, Hee-Gon;Lee, Jin-Woo;Bae, Yeoun-Ki;Kim, Woo-Jae;Lee, Jae-Sam;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.53-56
    • /
    • 2008
  • Modern society is experiencing a high population density and a centralization of facilities. The clear trends in the construction field are aggrandizement, elevation and specialization of building structures. Such trends require improvements of skills in raising material performances, structuring, planning, designing, and increasing construction capacities. In order to procure high performance materials and construction techniques, a top-quality concrete should be used since it takes up a large part of the material. In recent years, active researches have been done on the ultra high strength concrete. Therefore, this experimental study is strength management to fixed quantity in the field of ultra-strong concrete.

  • PDF

Evaluation on Mechanical Properties of PP Fiber Ultra High Strength Concrete at Elevated Temperatures (PP섬유 혼입에 따른 초고강도 콘크리트의 고온역학적특성 평가)

  • Bang, Deog-Yun;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Bo-Kyeong;Hwang, Eui-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.53-54
    • /
    • 2016
  • In this study, the effect of high temperature on the compressive strength and elastic modulus of ultra high strength concrete with PP fiber were experimentally investigated. As the result, the compressive strength and elastic modulus of ultra high strength concrete were irrespectively evaluated mixed ratio of PP fiber at high temperature.

  • PDF

Evaluation on Vapor Pressure of Ultra-high-strength Concrete by Heating Condition (가열조건에 따른 초고강도 콘크리트의 내부수증기압력 평가)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Yoon, Min-Ho;Lee, Bo-Kyeong;Seo, Won-woo;Baek, Jae-Uk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.224-225
    • /
    • 2017
  • Ultra-high-strength concrete exposed to high temperature is likely to cause spalling. Spalling is caused by the vapor pressure of the concrete, and the vapor pressure may be different depending on the heating conditions of the concrete. Therefore, in this study, a ring-type restrained specimen was fabricated using ultra-high-strength concrete and the vapor pressure generated in the concrete by heating condition(rapid and slow heating) was evaluated.

  • PDF

Elucidating the mechanical behavior of ultra-high-strength concrete under repeated impact loading

  • Tai, Yuh-Shiou;Wang, Iau-Teh
    • Structural Engineering and Mechanics
    • /
    • v.37 no.1
    • /
    • pp.1-15
    • /
    • 2011
  • The response of concrete to transient dynamic loading has received extensive attention for both civil and military applications. Accordingly, thoroughly understanding the response and failure modes of concrete subjected to impact or explosive loading is vital to the protection provided by fortifications. Reactive powder concrete (RPC), as developed by Richard and Cheyrezy (1995) in recent years, is a unique mixture that is cured such that it has an ultra-high compressive strength. In this work, the concrete cylinders with different steel fiber volume fractions were subjected to repeated impact loading by a split Hopkinson Pressure Bar (SHPB) device. Experimental results indicate that the ability of repeated impact resistance of ultra-high-strength concrete was markedly superior to that of other specimens. Additionally, the rate of damage was decelerated and the energy absorption of ultra-high-strength concrete improved as the steel fiber volume fraction increased.

A Basic Study on Developement of Ultra high-strength concrete (초고강도 콘크리트 개발에 위한 기초적 연구)

  • Son Young-Jun;Kim Han-sik;Yang Dong-Il;Han Da-Hee;Lee Young-Do;Jung Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.41-44
    • /
    • 2005
  • The aim of this study is to develop experimentally ultra high-strength concrete with compressive strength over 100MPa with current materials by important factors to influence the compressive strength of concrete. There are so many factors which influence the manufacturing of ultra high-strength concrete. But the experimental factors selected in this study are the sand aggregate ratio, the silica fume replacement ratio, the type of aggregate. the type of superplasticizer, the fiber mixing ratio. The results of this experimental study show that. it is possible to applicate in the field

  • PDF

Strategic Utilization of Fiber Reinforced UHSC in Slab-Column Connections

  • Yoon, Young-Soo;Lee, Joo-Ha;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.79-82
    • /
    • 2005
  • This study reports on the structural characteristics of slab-column connections using an ultra-high-strength-fiber-reinforced concrete from new and retrospective data. The parameters investigated were the ' puddling ' of ultra-high-strength-fiber-reinforced concrete and the use of high-strength concrete in the slab. The effects of these parameters on the punching shear capacity, negative moment cracking, and stiffness of the two-way slab specimens are investigated. Furthermore, the ACI Code (2002), the CSA Standard (1994), the BS Standard (1985) and the CEB-FIP Code (1990) predictions are compared to the experimental results obtained from some slab-column connections tested in this experiment and those tested by other investigators. The beneficial effects of the ultra-high-strength-fiber-reinforced concrete puddling and of the use of high-strength concrete are demonstrated. It is also concluded that the punching shear strength of slab-column connections is a function of the flexural reinforcement ratio.

  • PDF

Mixing and Strength Properties of 150MPa Ultra High Strength Concrete (150MPa 초고강도 콘크리트 배합 및 강도발현 특성)

  • Ahn, Jong-Mun;Kang, Hoon;Kim, Jong-Keun;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.373-376
    • /
    • 2008
  • Ultra High Strength Concrete(UHSC) is necessary a clear presentation about mechanical property that is different from normal strength concrete and an evaluation of serviceability of high rise building which is used ultra high strength concrete. To mixing ultra high strength concrete with $f_{ck}$=150MPa pre-mix cement were manufactured and experimental study were conducted to evaluated on the mixing properties and compressive strength with major variables as unit cement contents, water-binder ratio and type of pre-mix cement. As a test result, it is shown that the concrete mixing time is required about 5$^{\sim}$6 minute untill the each materials(ordinary portland cement, silica fume, blast-furnace slag powder and anhydrite) are revitalized enough. A slump flow of fresh concrete are shown about 700$^{\sim}$750mm with proper viscosity. And average value of concrete compressive strength are shown about 77% in 7days, 87% in 14days and 102% in 56days for 28days of concrete material age. From this experimental study, a proper mixture proportion of pre-mix cement are recommended about 54$^{\sim}$59% OPC, 25$^{\sim}$30% blast-furnace slag powder and 10$^{\sim}$15% silica fume for mix the ultra high strength concrete with $f_{ck}$=150MPa.

  • PDF

Study on the mix proprotion and the thermal crack of Ultra High Strength Concrete (초고강도 콘크리트의 배합 및 온도균열에 대한 연구)

  • Moon, Han-Young;Kim, Byoung-Kwon;Son, Young-Hyun;Kang, Hoon;Kim, Jeong-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.265-268
    • /
    • 1999
  • In this study, we manufactured the ultra-high strength concrete using mineral admixture which is easily workable. From the test results of compressive strength, It is concluded that the proper replacement ratio of silica fume should not exceed to 10% and the replacement of slag is more effective that the replacement of fly ash to gain very high compressive strength. Thermal stress analysis is conducted to find the way of controlling the thermal crack of ultra-high strength concrete. As results of thermal stress analysis, it was found that reducing placing temperature of concrete(pre-cooling) is effective to reduce thermal crack and placing concrete in high air temperature is more effective than placing concrete in low air temperature.

  • PDF

Spalling Reduction Methods of Ultra High-Strength Reinforced Concrete Columns (초고강도 콘크리트 기둥의 폭렬저감방안에 관한 실험적 연구)

  • Shin, Sung-Woo;Yoo, Suk-Hyeong;Kim, In-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.171-178
    • /
    • 2006
  • It was presented that the spalling of high strength concrete exposed to high temperature could be reduced by using polypropylene fiber. However, as the concrete strength increase, the demanded quantity of PP fiber increase and this results in the loss of workability of ultra high strength concrete. The silica fume which is essentially mixed in ultra high strength concrete decrease the permeability of concrete, and this will increase the degree of spalling. In this study the effect of silica fume on the spalling of ultra high strength concrete and the fire resisting efficiency of PP fiber and poly vinyl alchol, instead of PP fiber, for the security of workability were experimentally examined.

Residual Mechanical Properties of Ultra High Strength Concrete with Aggregate Factor (골재요인에 따른 초고강도 콘크리트의 잔존역학적 특성)

  • Lee, Hee-Kwang;Kim, Gyu-Yong;Lee, Tae-Gyu;Nam, Jeong-Soo;Koo, Kyung-Mo;Youn, Yong-Sang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.211-212
    • /
    • 2011
  • It was very important to evaluate concrete experimentally at elevated temperature because concrete was filled with aggregate of concrete volume about 70 percent. Concrete exposure to high temperatures produces changes in its internal structure, for instance loss of its strength and deformation capacity, in extreme cases risking the service life of the structure. The work of this paper is performed to evaluate the thermal behavior of ultra-high strength concrete having different water to cement ratio (strength), fine aggregate to aggregate ratio and maximum size of coarse aggregate. For exposure to 500℃ during 1 hour, residual mechanical properties of the ultra-high strength concrete decreased as the s/a ratio decreases and the maximum size of coarse aggregate increases.

  • PDF