• Title/Summary/Keyword: Ultimate bearing load

Search Result 247, Processing Time 0.028 seconds

Bearing Capacity of Shallow Foundation on Geogrid-Reinforced Clay (지오그리드로 보강된 점성토사의 얕은 기초의 지지력)

  • Shin, Bang Woong;Das, Braja M.;Shin, Eun Chul;Chung, Kee Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1439-1444
    • /
    • 1994
  • Laboratory model test results for the ultimate bearing capacity and allowable bearing capacity at various settlement levels conducted on a strip foundation supported by geogrid-reinforced clay soil have been presented. For mobilization of the maximum possible load-carrying capacity, the optimum width and depth of the reinforcement layers, and the location of the first layer of reinforcement with respect to the bottom of the foundation have been determined.

  • PDF

Experimental investigation on shear capacity of partially prefabricated steel reinforced concrete columns

  • Yang, Yong;Chen, Yang;Zhang, Jintao;Xue, Yicong;Liu, Ruyue;Yu, Yunlong
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.73-82
    • /
    • 2018
  • This paper experimentally and analytically elucidates the shear behavior and shear bearing capacity of partially prefabricated steel reinforced concrete (PPSRC) columns and hollow partially prefabricated steel reinforced concrete (HPSRC) columns. Seven specimens including five PPSRC column specimens and two HPSRC column specimens were tested under static monotonic loading. In the test, the influences of shear span aspect ratio and difference of cast-in-place concrete strength on the shear behavior of PPSRC and HPSRC columns were investigated. Based on the test results, the failure pattern, the load-displacement behavior and the shear capacity were focused and analyzed. The test results demonstrated that all the column specimens failed in shear failure mode with high bearing capacity and good deformability. Smaller shear span aspect ratio and higher strength of inner concrete resulted in higher shear bearing capacity, with more ductile and better deformability. Furthermore, calculation formula for predicting the ultimate shear capacity of the PPSRC and HPSRC columns were proposed on the basis of the experimental results.

Performance of BMSC column with large eccentricity under natural exposure conditions

  • Ma, Haiyan;Zeng, Xiangchao;Yu, Hongfa;Yue, Peng;Zhu, Haiwei;Wu, Chengyou
    • Structural Engineering and Mechanics
    • /
    • v.76 no.4
    • /
    • pp.541-550
    • /
    • 2020
  • As a new type of concrete material, basic magnesium sulfate cement concrete (BMSC) has the advantages, such as early strength, high strength, good toughness and crack resistance. However, it is unclear about the degradation of the mechanical properties of BMSC columns, which is exposed to the natural environment for several years. In order to apply this new concrete to practical engineering, six large-eccentricity compressive columns of BMSC were studied. The mechanical properties such as the crack propagation, failure morphology, lateral displacement and bearing capacity of BMSC column were studied. The results show that the degradation rate of ultimate load of BMSC column is from 6% to 7%. The degradation rate of the stiffness of the column is from 6% to 13%. With the increase of compressive strength of BMSC, the axial displacement and lateral displacement are gradually reduced. The calculation model of bearing capacity of the BMSC column under the large eccentric compression is proposed. This paper provides a reference for the application of BMSC columns in the civil engineering.

Estimation of resistance coefficient of PHC bored pile by Load Test (재하시험에 의한 PHC 매입말뚝의 저항계수 산정)

  • Park, Jong-Bae;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.233-247
    • /
    • 2017
  • In Europe and the USA, the use of limit state design method has been established, and the Korea Ministry of Land, Transport and Maritime Affairs has implemented the bridge substructure design standard based on the critical state. But Korean piling methods and ground conditions are different from Europe and USA, the limit state design method can not be used immediately. In this study, the resistance coefficient was proposed by comparing and analyzing the results of the static load test(9 times) and dynamic load tests(9 times of EOID and 9 times of Restrike) with the bearing capacity calculated by Meyerhof(LH design standard, Road bridge design standard) method and surcharge load method(using Terzaghi's bearing capacity coefficient and Hansen & Vesic's bearing capacity coefficient). The previous LHI study showed the resistance coefficient of the LH design standard was 0.36 ~ 0.44, and this research result showed the resistance coefficient was 0.39 ~ 0.48 which is about 8% higher than the previous study. In this study, we tried to obtain the resistance coefficient mainly from the static load test and the resistance coefficient was 0.57 ~ 0.69(Meyhof method : LH design standard) based on the ultimate bearing capacity and the resistance coefficient was 0.49 ~ 0.60(Meyhof method : LH design standard) based on the Davissons bearing capacity. The difference of the resistance coefficient between the static and dynamic load test was greater than that we expected, we proposed the resistance coefficient(0.52 ~ 0.62 : Meyerhof method: LH design standard) using the modified bearing capacity of the dynamic load test. Summarizing the result, the coefficient of resistance obtained from the static and dynamic load tests was 0.35 ~ 0.76, which is greater than 0.3 suggested by the Road bridge design standard, so the economical design might be possible using the coefficient of resistance proposed by this study.

Ultimate Capacity of Guardrail Supporting Pile Subjected to Lateral Impact Load Using Centrifuge Model Test (원심모형실험을 통한 차량방호울타리 지지말뚝의 수평방향 충격하중에 대한 극한지지력)

  • Yun, Jong Seok;Lee, Min Jy;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.25-36
    • /
    • 2019
  • The safety barrier is installed on road embankment to prevent vehicles from falling into road side slope. Among the safety barrier, flexible guardrails are usually installed. The flexible guardrail generally consists of a protection cross-beam and supporting in-line piles. These guardrail piles are installed nearby slope edge of road embankment because the side area of the road is much narrow. The protection cross-beam absorbs impact energy caused by vehicle collision. The pile-soil interaction also absorbs the rest of the impact energy and then, finally, the flexible guardrail system resists the impact load. This paper aims to investigate the pile-soil interaction subjected to impact load using centrifuge model tests. In this study, a single pile was installed in compacted residual soil and loaded under lateral impact load. An impact loading system was designed and developed available on centrifuge tests. Using this loading system, a parametric study was performed and the parameters include types of loading and ground. Finally, the ultimate bearing capacity of supporting pile under impact load was analyzed using load-displacement curve and soil reaction pressure distributions at ultimate were evaluated and compared with previous studies.

Static Behavior of Large Stud Shear Connectors (대직경 스터드 전단연결재의 정적거동)

  • Lee, Pil Goo;Shim, Chang Su;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.611-620
    • /
    • 2003
  • Shear studs with a diameter of 19mm or 22mm are typically used in steel-concrete composite bridge. For the simplification of details in steel bridges, the convenience of removing concrete slab, and the efficient distribution of shear pockets for precast decks, large studs can be an excellent alternative. Through push-out tests on large stud shear connectors that transcend the limitation of current design codes, static behavior was investigated and comparisons with design equations performed. The shear stiffness of the connectors in elastic range and trilinear load-slip curves were proposed after shear tests on 25mm, 27mm, and 30mm studs. The ultimate slip capacity and ultimate strength of large studs were also evaluated, with the test results revealing conservative values for the design shear strength in Eurocode-4. For 30mm stud shear connectors, the welding quality and bearing capacity of concrete slab should be improved.

Evaluation of Yield Load in Pile Load Tests on Driven Piles (관입말뚝에 대한 연직재하시험시 항복하중의 판정법)

  • 홍원표;심기석
    • Geotechnical Engineering
    • /
    • v.5 no.1
    • /
    • pp.7-18
    • /
    • 1989
  • In pile load tests on end bearing piles, generally, it is not possible to continue loading to the ultimate load. Thus, the concept of yield load has been introduced for determining design loads Iron the pile load test records. The conventional rules to determine the yield load were not available for evaluation on pile load test records obtained in 6 fields nearby westers 8r Southern Coasts in Korea. A new rule 9.as presented to determine easily the yield load, based on investigations on the pile load test records. The yield load of piles is determined at the infiection point on semi-logarithmic coordinates (P-logS), in which load is plotted in normal scale and settlement is plotted in logarithmic scale. This method may not only save much costs and times but also present safe luorking circumstances for pile load tests in field. It was found that the yield load represented the elastic limit of the pile load-settlement behalf.iota. The ultimate load, which is given at 25.4mm settlement on pile head, was 1.5 times of the yield load. The allowable long-term and short-term load capacities were, respectively, 50% and 75% of the yield load. The safety factors to get the allowable pile capacity were obtained as 2.0~4.0 for the equations to predict the static pile capacity.

  • PDF

Load Transfer Characteristics and Ultimate Bearing Capacity of PHC Pile in Deep Soft Clay Layer (대심도 연약지반에 근입된 PHC말뚝기초의 하중전이특성 및 극한지지력 산정)

  • Lee, Yonghwa;Kim, Myunghak
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • In this study, the analysis of load transition of PHC pile was performed with the static load test, which was driven in deep soft clay layer of MyungJi site in the western area of Pusan. The results of test showed that the range of unit side resistance of pile in sand layer were $7.4t/m^2$ to $23.3t/m^2$ and $6.4t/m^2$ in the soft clay layer, while the unit base resistance was $955t/m^2$ in dense silty sand layer. To select the most reasonable static bearing capacity formular, the field measured values are compared with the calculated ones from the suggested various formular. In the case of side resistance in sand layer, the suggest formular in the Structural Foundation Design Manual by KGS was most reasonable, while in clay layer Railroad Design Manual.

  • PDF

Failure Model for the Adhesively Bonded Tubular Single Lap Joints Under Static Tensile Loads (축방향하중에 대한 튜브형 단면겹치기 접착조인트의 전적 파괴모델에 관한 연구)

  • Kim, Yeong-Gu;Lee, Su-Jeong;Lee, Dae-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.5
    • /
    • pp.1543-1551
    • /
    • 1996
  • The static tensile load bearing capability of as adhesively-bonded tubular single lap jint that is calculated usign the linear mechanical properties of adhesive is usually far from the experimentally determined because the majority of the load transfer of the adhesively-bonded jointd is accomplished by the nonlinear behavior of the rubber-toughened eoxy adhesive. In this paper, both the nonlinear mechanical properties and the fabrication residual thermal stresses of adhesive were included in the calculation of the stresses of adhesively-bonded joints. The onlinear tensile properties of adhesive were approximated by an exponential form which was represented by the initial tensile modulus and ultimate tensile stength of adhesive. The stress distribution in the adhesive were calculated by applying the load obtained from the tensile tests. From the tensile tests and the stress analysis of adhesively-bonded hoints, the failure model for adhesively-bonded tubular single lap joints was proposed.

Study of the longitudinal reinforcement in reinforced concrete-filled steel tube short column subjected to axial loading

  • Alifujiang Xiamuxi;Caijian Liu;Alipujiang Jierula
    • Steel and Composite Structures
    • /
    • v.47 no.6
    • /
    • pp.709-728
    • /
    • 2023
  • Experimental and analytical studies were conducted to clarify the influencing mechanisms of the longitudinal reinforcement on performance of axially loaded Reinforced Concrete-Filled Steel Tube (R-CFST) short columns. The longitudinal reinforcement ratio was set as parameter, and 10 R-CFST specimens with five different ratios and three Concrete-Filled Steel Tube (CFST) specimens for comparison were prepared and tested. Based on the test results, the failure modes, load transfer responses, peak load, stiffness, yield to strength ratio, ductility, fracture toughness, composite efficiency and stress state of steel tube were theoretically analyzed. To further examine, analytical investigations were then performed, material model for concrete core was proposed and verified against the test, and thereafter 36 model specimens with four different wall-thickness of steel tube, coupling with nine reinforcement ratios, were simulated. Finally, considering the experimental and analytical results, the prediction equations for ultimate load bearing capacity of R-CFSTs were modified from the equations of CFSTs given in codes, and a new equation which embeds the effect of reinforcement was proposed, and equations were validated against experimental data. The results indicate that longitudinal reinforcement significantly impacts the behavior of R-CFST as steel tube does; the proposed analytical model is effective and reasonable; proper ratios of longitudinal reinforcement enable the R-CFSTs obtain better balance between the performance and the construction cost, and the range for the proper ratios is recommended between 1.0% and 3.0%, regardless of wall-thickness of steel tube; the proposed equation is recommended for more accurate and stable prediction of the strength of R-CFSTs.