• 제목/요약/키워드: Ultimate Tensile Strength

검색결과 494건 처리시간 0.025초

교정용 강선재의 열처리 효과에 관한 실험적 연구 (THE EFFECTS OF HEAT TREATMENT OF ORTHODONTIC WIRES)

  • 이명석;손병화
    • 대한치과교정학회지
    • /
    • 제22권3호
    • /
    • pp.591-602
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of heat treatment on physical properties of 0.016' and 0.016' x 0.022' stainless steel wires. Temperature of heat treatment had intervals of $50^{\circ}C$ from $400^{\circ}C$ to $700^{\circ}C$, and time of heat treatment were 3, 6 and 9 minutes. Tensile tests were measured by ultimate tensile strength and yield strength. Bending tests were assessed by maximum bending force, recovery force, and stiffness. Torsion test was evaluated by torsion cycle until wires were fractured. The results were as follows: 1. In round wires, the highest value of ultimate tensile strength and yield strength were recorded of heat treatment at $500^{\circ}C$. In rectangular wires, the highest value of ultimate tensile strength were after 9 minutes at $400^{\circ}C,\;450^{\circ}C$ and 3, 6 minutes of heat treatment at $50^{\circ}C$, yield strength were the highest value after 3, 6 minutes of heat treatment at $500^{\circ}C$. 2. In both round and rectangular wires, maximum bending force and recovery force were the highest values after 6 minutes of heat treatment at $500^{\circ}C$. In round wires, highest value of stiffness were formed after 9 minutes at heat treatment at $500^{\circ}C$. In rectangular wires, the highest value of stiffness were for 6 minutes in $500^{\circ}C$. 3. In rectangular wires, torsion cycle was minimum after 6 minutes of heat treatment at $500^{\circ}C$. 4. In all of tension, bending, and torsion tests, the heat treated wires were softened over at $700^{\circ}C$. 5. In all of tension, bending, and torsion tests, physical properties of the wires were more influenced by the temperatures than the duration of the heat treatment.

  • PDF

동적무기력계수에 의한 고장력강의 동적.충격강도 특성 평가 (The Estimation of Dynamic/Impact Strength Characteristics of High Tensile Steel by Dynamic Lethargy Coefficient)

  • 송준혁;박정민;채희창;강희용;양성모
    • 한국자동차공학회논문집
    • /
    • 제10권2호
    • /
    • pp.96-100
    • /
    • 2002
  • The purpose of this paper is presented a rational method of predicting dynamic/impact tensile strength of high tensile steel materials widely used fur structural material of automobiles. It is known that the ultimate strength is related with the loading speed and the Lethargy Coefficient from the tensile test. The Dynamic Lethargy Coefficient is proportional to the disorientation of the molecular structure and indicates the magnitude of defects resulting from the probability of breaking the bonds responsible for its strength. The coefficient is obtained from the simple tensile test such as failure time and stresses at fracture. These factors not only affect the static strength but also have a great influence on the dynamic/impact characteristics of the joist and the adjacent structures. This strength is used to analyze the failure life prediction of mechanical system by virtue of its material fracture. The impact tensile test is performed to evaluate the life parameters due to loading speed with the proposed method. Also the evaluation of the dynamic/impact effect on the material tensile strength characteristics is compared with the result of Campbell-Cooper equation to verify the proposed method.

Square CFST columns under cyclic load and acid rain attack: Experiments

  • Yuan, Fang;Chen, Mengcheng;Huang, Hong
    • Steel and Composite Structures
    • /
    • 제30권2호
    • /
    • pp.171-183
    • /
    • 2019
  • As China's infrastructure continues to grow, concrete filled steel tubular (CFST) structures are attracting increasing interest for use in engineering applications in earthquake prone regions owing to their high section modulus, high strength, and good seismic performance. However, in a corrosive environment, the seismic resistance of the CFST columns may be affected to a certain extent. This study attempts to investigate the mechanical behaviours of square CFST members under both a cyclic load and an acid rain attack. First, the tensile mechanical properties of steel plates with various corrosion rates were tested. Second, a total of 12 columns with different corrosion rates were subjected to a reversed cyclic load and tested. Third, comparisons between the test results and the predicted ultimate strength by using four existing codes were carried out. It was found that the corrosion leads to an evident decrease in yield strength, elastic modulus, and tensile strain capacity of steel plates, and also to a noticeable deterioration in the ultimate strength, ductility, and energy dissipation of the CFST members. A larger axial force ratio leads to a more significant resulting deterioration of the seismic behaviour of the columns. In addition, the losses of both thickness and yield strength of an outer steel tube caused by corrosion should be taken into account when predicting the ultimate strength of corroded CFST columns.

Mg-Zn-(Mn)-Ca 합금의 미세조직 및 기계적성질 (Mechanical Properties and Microstructure of Mg-Zn-(Mn)-Ca Alloys)

  • 엄정필;차동득;임수근;허보영
    • 한국주조공학회지
    • /
    • 제17권6호
    • /
    • pp.592-597
    • /
    • 1997
  • The microstructure and tensile properties of Mg-Zn-Ca and Mg-Zn-Mn-Ca alloys have been investigated. The alloys were obtained by melting in a low carbon crucible coated with boron nitride under an Ar gas atmosphere to prevent oxidation and combustion. The Mg alloy melt was cast into the metallic mold at room temperature, and cooling part was located at the bottom of mold. The phase formed during solidification of the Mg-Zn-(Mn) alloys containing 0.5%Ca is $Ca_2Mg_6Zn_3$. The yield strength and ultimate tensile strength of the alloys increased with increasing Zn content, but the ductility did not change with increasing Zn content. The addition of Mn improves the yield strength and ultimate tensile strength of the alloys, but the ductility did not change. Tensile fracture of the alloys revealed brittle failure, with cracking along the $Ca_2Mg_6Zn_3$ phase. The variation of stress with strain obeyed the relationship of the ${\sigma}=K{\varepsilon}^n$.

  • PDF

PDP 격벽 재료의 인장 물성 측정 방법 (Measurement Method for Tensile Properties of PDP's Barrier Rib Materials)

  • 오충석;배종성;홍병규
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.91-98
    • /
    • 2009
  • A reliable tensile test technique for PDP's barrier rib materials was introduced. A tensile specimen was prepared by punching out of green sheet, curing the specimen in a high temperature furnace, attaching sand paper tabs on each grip ends, and then attaching two strain gages for the strain monitoring and specimen alignment. Preliminary tensile tests were successfully done with the specimens made from ZnO-based lead-free green sheet. The specimens cured at 3 different maximum curing temperatures were tested to demonstrate the applicability of the test method. The Young's modulus was 88 ${\pm}$ 4 GPa regardless of the maximum curing temperature. The ultimate tensile strength was decreased with increasing the temperature. The tensile test method proposed in this study was proven to be reliable, useful and easy to estimate the bulk mechanical properties of barrier rib materials.

자유단 충간분리를 갖는 복합재 적층판의 최종 파괴강도 (Ultimate Strength of Composite Laminates with Free-Edge Delamination)

  • 양광영;윤성운;김재열
    • 한국공작기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.59-64
    • /
    • 2002
  • This paper presets experimental and analytical studies of ultimate strength of [$[30_2/-30_2/90]_S$ carbon/epoxy laminates with free-edge delamination under uniaxial tension. We performed tensile teat far laminates with Telflon inserted on interfaces to simulate initial free-edge delamination, The experiment reveals that extensional stiffness of the laminate decreases by the initiation of the delamination, and that strength of the laminate without delamination is smaller than that of the laminates with delamination. Generalized quasi-three delamination finite element analysis, which employs energy release rate and maximum stress criteria, predicts the ultimate strength of the laminates with sufficient accuracy.

Effect of stress-strain curve changing with equal channel angular pressing on ultimate strength of ship hull stiffened panels

  • Sekban, Dursun Murat;Olmez, Hasan
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.473-484
    • /
    • 2021
  • Similar to other structures, ultimate strength values showing the maximum load that the structure can resist without damaging has great importance on ships. Therefore, increasing the ultimate strength values will be an important benefit for the structure. Low carbon steels used in ships due to their low cost and good weldability. Improving the ultimate strength values without interfering with the chemical composition to prevent of the weldability properties of these steels would be very beneficial for ships. Grain refinement via severe plastic deformation (SPD) is an essential strengthening mechanism without changing the chemical composition of metallic materials. Among SPD methods, equal channel angular pressing (ECAP) is one of the most commonly used one due to its capacity for achieving bulk ultrafine-grained (UFG) materials. When the literature is examined, it is seen that there is no study about ultimate strength calculation in ships after ECAP. Therefore, the mean purpose of this study is to apply ECAP to a shipbuilding low carbon steel to be able to achieve mechanical properties and investigate the alteration of ship hull girder grillage system's ultimate strength via finite element analysis approach. A fine-grained (FG) microstructure with a mean grain size of 6 ㎛ (initial grain size was 25 ㎛) was after ECAP. This microstructural evolution brought about a considerable increase in strength values. Both yield and tensile strength values increased from 280 MPa and 425 MPa to about 420 MPa and 785 MPa, respectively. This improvement in the strength values reflected a finite element method to determine the ultimate strength of ship hull girder grillage system. As a result of calculations, it was reached significantly higher ultimate strength values (237,876 MPa) compared the non-processed situation (192,986 MPa) on ship hull girder grillage system.

Experimental and numerical studies on the behaviour of corroded cold-formed steel columns

  • Nie, Biao;Xu, Shanhua;Zhang, Haijiang;Zhang, Zongxing
    • Steel and Composite Structures
    • /
    • 제35권5호
    • /
    • pp.611-625
    • /
    • 2020
  • Experimental investigation and finite element analysis of corroded cold-formed steel (CFS) columns are presented. 11 tensile coupon specimens and 6 stub columns of corroded CFS that had a channel section of C160x60x20 were subjected to monotonic tensile tests and axial compression tests, respectively. The degradation laws of the mechanical properties of the tensile coupon specimens and stub columns were analysed. An appropriate finite element model for the corroded CFS columns was proposed and the influence of local corrosion on the stability performance of the columns was studied by finite element analysis. Finally, the axial capacity of the experimental results was compared with the predictions obtained from the existing design specifications. The results indicated that with an increasing average thickness loss ratio, the ultimate strength, elastic modulus and yield strength decreased for the tensile coupon specimens. Local buckling deformation was not noticeable until the load reached about 90% of the ultimate load for the non-corroded columns, while local buckling deformation was observed when the load was only 40% of the ultimate load for the corroded columns. The maximum reduction of the ultimate load and critical buckling load was 57% and 81.7%, respectively, compared to those values for the non-corroded columns. The ultimate load of the columns with web thickness reduced by 2 mm was 53% lower than that of the non-corroded columns, which indicates that web corrosion most significantly affects the bearing capacity of the columns with localized corrosion. The results predicted using the design specifications of MOHURD were more accurate than those predicted using the design specifications of AISI.

고인성 시멘트복합체의 인장성능평가에 관한 연구 (A Study on the Estimation of Tensile Properties of High Performance Fiber Reinforced Cementitious Composites)

  • 한병찬;김재환;임승찬;전용재;정연석;권영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.357-360
    • /
    • 2006
  • In this study, it was proposed a direct tensile testing machine(DTTM) to be simple and to be applied to High Performance Fiber Reinforced Cementitious Composites(HPFRCCs), and it was examined the tensile properties of HPFRCCs by this machine. As a results, it was confirmed that a direct tensile test of HPFRCCs could be certainly carried out DTTM to be developed in this study. Also, tensile strength and yield strength of HPFRCCs were similar regardless of specimens thickness. And, all specimens revealed the stable strain-hardening behavior and multiple cracking in flexible and tensile loads. But, deviation of strain at ultimate tensile strength increased with the increase of specimen thickness.

  • PDF

Experimental study on the tensile strength of gravelly soil with different gravel content

  • Ji, Enyue;Chen, Shengshui;Zhu, Jungao;Fu, Zhongzhi
    • Geomechanics and Engineering
    • /
    • 제17권3호
    • /
    • pp.271-278
    • /
    • 2019
  • In recent years, the crack accidents of earth and rockfill dams occur frequently. It is urgent to study the tensile strength and tensile failure mechanism of the gravelly soil in the core for the anti-crack design of the actual high earth core rockfill dam. Based on the self-developed uniaxial tensile test device, a series of uniaxial tensile test was carried out on gravelly soil with different gravel content. The compaction test shows a good linear relationship between the optimum water content and gravel content, and the relation curve of optimum water content versus maximum dry density can be fitting by two times polynomial. For the gravelly soil under its optimum water content and maximum dry density, as the gravel content increased from 0% to 50%, the tensile strength of specimens decreased from 122.6 kPa to 49.8 kPa linearly. The peak tensile strain and ultimate tensile strain all decrease with the increase of the gravel content. From the analysis of fracture energy, it is proved that the tensile capacity of gravelly soil decreases slightly with the increasing gravel content. In the case that the sample under the maximum dry density and the water content higher than the optimum water content, the comprehensive tensile capacity of the sample is the strongest. The relevant test results can provide support for the anti-crack design of the high earth core rockfill dam.