• Title/Summary/Keyword: Ulchin NPP

Search Result 12, Processing Time 0.029 seconds

ASSESSMENT OF THE SAFETY OF ULCHIN NUCLEAR POWER PLANT IN THE EVENT OF TSUNAMI USING PARAMETRIC STUDY

  • Kim, Ji-Young;Kang, Keum-Seok
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.175-186
    • /
    • 2011
  • Previous evaluations of the safety of the Ulchin Nuclear Power Plant in the event of a tsunami have the shortcoming of uncertainty of the tsunami sources. To address this uncertainty, maximum and minimum wave heights at the intake of Ulchin NPP have been estimated through a parametric study, and then assessment of the safety margin for the intake has been carried out. From the simulation results for the Ulchin NPP site, it can be seen that the coefficient of eddy viscosity considerably affects wave height at the inside of the breakwater. In addition, assessment of the safety margin shows that almost all of the intake water pumps have a safety margin over 2 m, and Ulchin NPP site seems to be safe in the event of a tsunami according to this parametric study, although parts of the CWPs rarely have a margin for the minimum wave height.

Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site (원자력발전소 비상디젤발전기의 가동중 진동저감 효과)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF

A Study on Effect of Capture Volume in a Cavity on Direct Containment Heating Phenomena

  • Chung, C.Y.;Kim, M.H.;Lee, H.Y.;Kim, P.S.
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.290-298
    • /
    • 1996
  • Direct Containment Heating, DCH, is supposed to occur during a core melt-down accident if the primary system pressure is still high at the time of vessel breach in a Nuclear Power Plant (NPP). In this case, DCH is considered to be one of very important severe phenomena during postulated severe accident scenario because of the fast heat transfer rate to atmosphere and the sharp pressure increase in a containment. To reduce the effect of this DCH phenomena, the capture volume wes designed at Ulchin NPP units 3 and 4. But, the effect of this has not been studied extensively. This work consists of experimental and numerical analyses of the effects of capture volume in the cavity on DCH phenomena. The experimental model is a 1/30 scaled-down model of Ulchin NPP units 3 and 4. We used three types of capture volumes to investigate the effect of size. Numerical analysis using CONTAIN 1.2 is performed with the correlation for the dispersed fraction of molten corium from the cavity into the containment derived from the experimental data to examine the effect of capture volume on DCH phenomena in full scale of Ulchin NPP units 3 and 4.

  • PDF

Analysis of 766 keV Gamma Peak from NPP Environmental Samples (원전주변 환경시료의 766 keV 감마선에너지 피크에 대한 해석)

  • Kim, Wan;Lee, Hae-Young;Yang, He-Sun;Park, Hae-Soo;Kim, Bong-Kuk;Park, Hwan-Bae;Kim, Hong-Joo;Lee, Sang-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.190-194
    • /
    • 2009
  • Gamma spectral results for macroalgae samples taken from the environment of Ulchin nuclear power plants in Korea (east coast), showed 766 keV peaks, which were identified as $^{95}Nb$ by several research institutes. After the enhancement of liquid radioactive waste disposal facility at Ulchin NPP site, the $^{95}Nb$ amount in the liquid radioactive waste outflow has drastically reduced, but the expected reduction in $^{95}Nb$ specific activity from environmental samples did not actually show up on gamma spectroscopy. Detailed re-investigation revealed that along with 766 keV peak, other peaks (63, 92 and 1001 keV) from $^{234}Th-^{234}mPa$ decay series were also detected on spectroscopy, and that the measured half lives of the four peaks were very close to known half life of $^{234}Th-^{234}mPa$ decay series, which is 24.1 day. The measured gamma yield ratios of 766 keV peak to 1001 peak were very close to known ratio 0.35 for $^{234}mPa$. It is concluded that 766 keV peaks on gamma spectroscopy of Ulchin NPP environmental samples were mainly from $^{234}mPa$, which is one of naturally occurring radionuclides.

Improvement Methods in NPP's Radiation Emergency Plan: An Administrative Approach (행정적 대응을 중심으로 본 원전 방사선비상계획 개선방안)

  • Lee, Yoon-Wook;Yang, He-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.151-154
    • /
    • 2009
  • The Radiation Emergency Plan (REP) can be divided into a technical and an administrative responses. The domestic NPP's REPs are reviewed from the viewpoint of the administrative response and improvement methods are also suggested in this treatise. The fields of the reviews are the composition of the emergency response organizations, the activation criteria of the organizations, the selection of the staffings and the reasonableness of the REP's volume. In addition, the limitations of the current radiation exercises are reviewed and the improvement method of the exercise is presented. It is expected that the suggested recommendations will be helpful in establishing useful REPs and making practical radiation exercises in Korea.

Performance upgrade and analysis report for nuclear safety related emergency diesel generator speed control system (원전 안전등급 비상디젤발전기 속도제어시스템 성능개선 및 분석에 관한 연구)

  • Kim, Y.S.;Jeon, I.Y.;Lee, S.G.;Kim, C.K.;Ahn, J.W.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.581-583
    • /
    • 2005
  • The paper is final report for speed control upgrade and analysis report which recently performed on PWR NPP safety related EDG KHNP Ulchin NPP No.2 Unit. The upgraded system includes more beneficial function like as 'Slow start with starting ramp', 'Generator load sensing & control capability' and 'Emergency ramp during slow start'. This paper shows functional operation of slow start regime according to NRC regulatory guide which guide regulation to NPP safety related environment.

  • PDF

Phase Separation Algorithm for Ex-core Neutron Signal Analysis

  • Jung, Seung-Ho;Kim, Tae-Ryong
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.399-405
    • /
    • 1997
  • In this study a new phase separated spectral analysis algorithm is proposed to identify CSB vibration mode directly from ex-core neutron signals. Ex-core neutron signals can be decomposed into the global, core support barrel (CSB) beam mode, and CSB shell mode components by the new phase separation algorithm based on the characteristics of Fourier transform. By using the proposed algorithm and the conventional spectral analysis the vibration mode of the CSB and the fuel assembly of Ulchin-1 NPP were identified from measured ex-core neutron signals.

  • PDF

Evaluation of Vibration Characteristics of Operating Rotational Machines Depending of Types of Foundation (기초형식에 따른 회전기기의 가동중 진동특성 분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.63-72
    • /
    • 2007
  • The Emergency Diesel Generator (EDG) is a very important equipment for the safety of a Nuclear Power Plant (NPP). In this study, the operating vibration of three kinds of EDG systems was measured. The target EDG systems are Yonggwang 5 unit and Ulchin 2 and 3 units. The Yonggwang 5 and Ulchin 3 unit EDG systems are the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of these measurements is for a verification of the vibration isolation effect depending on the foundation system. As a result, It can be said that the spring and viscous damper system of the EDG performed better for the vibration isolation than that of anchor bolt type.