• Title/Summary/Keyword: UV-Vis method

Search Result 601, Processing Time 0.03 seconds

Application of UV-Vis Spectroscopic Analysis for Transformer Insulating Paper Degradation (UV-Vis 분광분석에 의한 전기변압기 내 절연지 열화도 측정)

  • Kong, Hosung;Han, Hung-Gu
    • Tribology and Lubricants
    • /
    • v.35 no.3
    • /
    • pp.151-157
    • /
    • 2019
  • Insulated oil degradation produces charged by-products, such as acids and hydro-peroxides, which tend to reduce the insulating properties of the oil. In this study, UV-vis spectroscopy measurement technology is developed and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate its ability to monitor the degradation of electrical insulating paper. The degradation characteristics of the insulating paper are appropriately represented through various types of measurement methods, such as the Tan (delta) method, $CO_2$ gas production measurement, the titration method, and IR spectroscopy. The results are demonstrated to be well comparable to a change in the fluorescence emission ratio (FER), which is defined as the shift in fluorescence intensity in the measured wavelength range, and also to the chromatic ratio, which is defined as a color shift to longer wavelength ranges. The results also show that, by using UV-vis spectroscopy, it is possible to detect the degradation of the insulating paper. This study suggests that UV-vis spectroscopy can be applied as an alternative to high-performance liquid chromatography, which is the internationally recognized measurement technology for cellulose paper degradation. The FER detector is also verified to be useful as an effective condition-monitoring device for power transformers.

Determination of C3G Content in Blackish Purple Rice using HPLC and UV-Vis Spectrophotometer

  • Ryu, Su-Noh;Park, Sun-Zik;Kang, Sam-Sik;Han, Sang-Jun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.5
    • /
    • pp.369-371
    • /
    • 2003
  • Cyanidin 3-glucoside (C3G) content contained in the grains of blackish purple rice varieties, Heugjinjubyeo, Kilimheugmi, Heugnambyeo, Sanghaehy-anghyeolla, and the progenies derived from their crosses was evaluated by HPLC and UV-Vis spectroscopy. C3G content was higher in the range of 10-30% by using UV-Vis method compared to HPLC method. A significant linear relationship was, however, observed between two analytical methods. The correlation coefficient was 0.98. Thus, this results suggested that it would be able to use UV-Vis spectroscopy to determine C3G content which does not demanded precise value like selection.

Simultaneous determination of betaine and choline using derivatization by HPLC with UV detection (HPLC-UV검출방법으로 유도체화를 통한 비테인과 콜린의 동시분석)

  • Rhee, Insook;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.112-116
    • /
    • 2015
  • Extraction of quaternary ammonium compounds (choline and betaine) from plant samples (spinach) using ion exchange resin (AG1, OH form) is a very simple and inexpensive approach. However, it is very hard to determine amounts of choline and betaine simultaneously using high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. Unlike choline, betaine has low molar absorptivity in UV-visible (UV-Vis) region, which makes it difficult to carry out UV-Vis detection of betaine. The mixture of quaternary ammonium compounds (choline and betaine) was derivatized using 2-bromo acetophenone as a derivatizing agent. As a result, choline did not react with the derivatizing agent, whereas betaine formed a betaine derivative. This betaine derivative exhibited detectable UV absorption with baseline separation between choline and the betaine derivative. Thus, with this method, choline and betaine can be determined simultaneously by using the HPLCUV method through one-step derivatization, which is an easy, sensitive, and reliable method.

Synthesis of CdSe-TiO2 Photocatalyst and Their Enhanced Photocatalytic Activities under UV and Visible Light

  • Lim, Chang-Sung;Chen, Ming-Liang;Oh, Won-Chun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.1657-1661
    • /
    • 2011
  • In this study, CdSe-$TiO_2$ photocatalyst were synthesized by a facile solvothermal method and characterized by X-ray diffraction (XRD), Scanning electron microscopy (SEM) with energy dispersive X-ray (EDX) analysis and UV-vis diffuse reflectance spectrophotometer. The photocatalytic activity was investigated by degrading methylene blue (MB) in aqueous solution under irradiation of UV light as well as visible light. The absorbance of degraded MB solution was determined by UV-vis spectrophotometer. The results revealed that the CdSe-$TiO_2$ photocatalyst exhibited much higher photocatalytic activity than $TiO_2$ both under irradiation of UV light as well as visible light.

A Quantitative Analysis Method for Studing AKD Hydrolysis (AKD 가수분해 연구를 위한 정량분석 방법)

  • 민춘기;신동소
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.3
    • /
    • pp.29-37
    • /
    • 1998
  • In order to set up a proper AKD quantification method for studing AKD hydrolysis, a quantitative analysis method using Uv/vis spectroscopy was evaluated and compared to the conventional GC-MS analysis. Hydrolysis rates of AKD emulsions during storage at 4$0^{\circ}C$ were measured by the UV/vis analysis. Owing to its simplicity and capability of measuring the unreacted AKD significantly even in a small amount, UV/vis method proved to be more suitable for studing AKD hydrolysis than GC-MS analysis. AKD hydrolysis was affected by the types of emulsifiers. Polymer stabilized AKD emulsion hydrolyzed more rapidly than starch stabilized AKD.

  • PDF

Method comparison for analyzing formaldehyde in marker pen ink (마킹펜 잉크 내 폼알데하이드 분석법 비교)

  • Park, Kwang Seo;Kim, Yong Shin;Choe, Eun Kyung
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.115-124
    • /
    • 2020
  • Marker pens belong to school things that are controlled by the regulation system called safety confirmation under special act on the safety of products for children with the formaldehyde criteria of 20 mg/kg. With nine marker pens available commercially, formaldehyde in marker pen ink was analyzed by present test standard where marking on a fabric swatch with a pen and extracting the swatch in water and derivatization with Nash reagent followed by UV/Vis spectrophotometeric measurement (Nash-UV/Vis method), giving not detected results or a false positive result in case of a colored water extract. However, the contents of formaldehyde in ink of nine marker pens were determinded to range between 3.2 ~ 93.2 mg/kg with three results above the safety criteria of 20 mg/kg by HPLC/DAD measurements on DNPH derivatives of formaldehyde (DNPH-HPLC/DAD method) in ink dissolved directly in water using an ultrasonic bath. Therefore, the DNPH-HPLC/DAD method with the extraction of ultrasonic dissolving ink in water is proposed as a proper method for analyzing formaldehyde in ink. The proposed method has advantages of lower detection limit and accuracy with colored extracts as well as a simple and fast extraction. The accuracy and precision of this method was estimated to be 90.1 ~ 105.4 % and 0.6 ~ 3.3 %, respectively by spiking tests in the ranges of 20 mg/kg and 40 mg/kg using matrixes such as highlighter pen ink, board marker ink, chalk marker pen ink and painter marker ink.

Optimum Concentration of the Cd(II)-Quercetin Complexation Reaction (Quercetin의 카드뮴 착물반응에 대한 최적농도)

  • Lee, Jeong-Ho;Shin, Sun-Woo;Baek, Seung-Hwa
    • YAKHAK HOEJI
    • /
    • v.53 no.5
    • /
    • pp.235-240
    • /
    • 2009
  • The interaction of cadmium (II) ion with quercetin was investigated in aqueous solution at different pH. The quercetin/cadmium stochiometries for cadmium (II) binding have been determined by UV-vis spectrophotometric method. The complexation of Cd(II) ion with 54.72 ${\mu}M$ quercetin (A=1.00793) was formed in 0.2 M $NH_3-0.2$ M $NH_4Cl$ (pH 8.0) buffer solution. 1:1 Cd(II)-complex had a maximum absorbance and showed the bathochromic shift of the long-wavelength band of the UV-vis spectra in the alkaline pH when interacted with quercetin in buffer solution. These results suggest that Cd(II)-quercetin complex has the optimal condition of chelation in basic buffer solution.

Ultraviolet Blocking Material Based on Silver-doped Hydroxyapatite (수산화인회석에 은이 도입된 자외선차단재료)

  • Pyo, Eunji;Kim, Youngyong;Kwon, Ki-Young
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.669-671
    • /
    • 2016
  • Hydroxyapatite (HAP) was prepared by a hydrothermal synthesis method and also silver was introduced on the surface of HAP through an ion exchange reaction. The crystal phase and morphology of HAP were then evaluated by X-ray diffraction (XRD) and transmission electron microscopy (TEM). In addition, the absorption property of HAP was characterized by diffuse reflectance UV-Vis spectroscopy. The presence of silver nanoparticles on the surface of HAP was also verified by XRD and TEM analysis. Particularly, the silver doped HAP showed an enhanced absorption property in UV-Vis region compared to that of the pristine HAP.

Mass Balance Method for Purity Assessment of Organic Reference Materials: for Thermolabile Materials with LC-UV Method

  • Lee, Joonhee;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3275-3279
    • /
    • 2014
  • A mass balance method for purity assessment of thermolabile organic reference materials was established by combining several techniques, including liquid chromatography with UV/VIS detector (LC-UV), Karl-Fischer (K-F) Coulometry, and thermal gravimetric analysis (TGA). This method was applied to three fluoroquinolones like enrofloxacin, norfloxacin and ciprofloxacin. LC-UV was used to analyze structurally related organic impurities based on UV/VIS absorbance spectra obtained in combination with LC separation. For all three organic reference materials, the UV/VIS spectra of the separated impurities were similar to that of the major component of the corresponding materials. This indicates that the impurities are structurally related to the respective reference material sharing common chromophores. Impurities could be quantified by comparing their absorbances at the wavelength of maximum absorbance (${\lambda}_{max}$). The water contents of the reference materials were measured by K-F Coulometry by an oven-drying method. The total inorganic impurities contents were assayed from ash residues in TGA analysis with using air as a reagent gas. The final purities estimated from results of those analytical techniques were assigned as ($99.91{\pm}0.06$), ($97.09{\pm}0.17$) and ($91.85{\pm}0.17$)% (kg/kg) for enrofloxacin, norfloxacin and ciprofloxacin, respectively. The assigned final purities would be applied to the reference materials which will be used as calibrators for the certification of those compounds in matrix CRMs as starting points for the traceability of their certified values to SI units.

Some considerations for the analytical approaches to measure atmospheric ammonia: tests on a relative performance of a portable colorimeter against UV/VIS spectrophotometer (대기 중 암모니아 성분의 분석법 연구: UV/VIS 분광계를 이용한 간이비색계의 상대 성능평가)

  • Kim, K.H.;Park, S.Y.;Kim, S.T.
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.425-430
    • /
    • 2005
  • In this study, we investigated the performance of a portable colorimeter used for the measurements of atmospheric ammonia against the more reliable method like UV/VIS spectrophotometer. For the purpose of this study, we tested a portable colorimeter and UV/VIS spectrophotometer for such basic analytical parameters as detectibility, reproducibility, linearity, and accuracy. According to our study, the performance of the colorimeter was fairly good to show a good agreement with the UV/VIS system. However, the performance of colorimeter suffered from both low and high concentration ranges: it was found to have very poor reproducibility at lower concentration (below $10\mu}g$), while its linear dynamic range was limited at the upper end (e.g., near $100{\mu}g$). If we assume that air samples are collected up to 30 liter, it implies that the colorimeter can be used to measure samples containing NH3 in the range of 500 ppb to 5 ppm (without the aid of diluting technique). Consequently, we recommend the use of such instrument with the awareness of its basic properties pertaining to the fundamental performance (such as its detectable range).