Purpose: The purpose of this study is to demonstrate inactivation effect of UVA-LED ultraviolet radiation upon Pseudomonas aeruginosa and Staphylococcus aureus which are the major bacteria causing eye diseases. Methods: The small sterilization device was made using UVA-LED of 400 nm. After Pseudomonas aeruginosa was diluted to $10^{-7}$ and Staphylococcus aureus to $10^{-5}$ and diluted solutions were put onto each liquid medium. They were irradiated by 400 nm of UVA for different amount of time; 15 min, 30 min, 60 min, 120 min, 240 min, 360 min and 480 min each. Results: The data from sterilization test was solved to regression line equation and the target log inactivation was obtained. The 3 log inactivation UV irradiation value of Pseudomonas aeruginosa was 54,847 UV dose ($mJ/cm^2$) and irradiation time was 135.42 min while the 3 log inactivation of Staphylococcus aureus was 39,066 UV dose ($mJ/cm^2$) and irradiation time was 98.72 min. Conclusions: The inactivation effect of sterilization method using 400 nm of UVA-LED upon Pseudomonas aeruginosa and Staphylococcus aureus has been verified and it is considered as a useful method in inactivating the contact lenses.
In order to continuously perform quarantine in public places, it is not easy to secure manpower, but using self-driving-based robots can solve problems caused by manpower. Self-driving-based quarantine robots can continuously prevent the spread of harmful viruses and diseases in public institutions and hospitals without additional manpower. The location of the autonomous driving function was estimated by applying the Pinnacle filter algorithm, and the UV sterilization system and chlorine dioxide injection system were applied for quarantine. The driving time is more than 3 hours and the position error is 0.5m.Soon, the stop-avoidance function was operated at 95% and the obstacle detection distance was 1.5 m, and the automatic charge recovery was charged by moving to the charging cradle at the remaining 10% of the battery capacity. As a result of quarantine with an unmanned quarantine system, UV sterilization is 99% and chlorine dioxide is sterilized more than 95%, which can contribute to reducing enormous social costs.
Journal of the Korea Academia-Industrial cooperation Society
/
v.17
no.6
/
pp.199-206
/
2016
The aim of this study was to establish the optimal conditions to design a shoe rack that could effectively sterilize and deodorize shoes contaminated by various bacteria. The manufacture and evaluation of a shoe rock was conducted for one year from October 2014 to September 2015. The antibacterial efficacies were evaluated using Escherichia coli and Staphylococcus aureus by JIS Z 2801:2010. The deodorization efficiency was identified by the standard method for deodorization efficiency evaluation of an indoor air cleaner established by Korea Air Cleaning Association, SPS-KACA002-132:2006. The results showed that antibacterial evaluation showed more than 99.9% of the sterilization effects on Escherichia coli and Staphylococcus aureus after exposure to ultraviolet (UV) light for 30 seconds. The average deodorization efficiency for the test gases was 42.5%. The temperature in the shoes and in the shoe rack was lower than $40^{\circ}C$ and $25^{\circ}C$, respectively, when the UV lamp was turned on for 5 minutes and off for 25 minutes repeatedly. This was controlled by turning the UV lamp on and off to maintain the appropriate temperature in the shoes. In conclusion, the real deodorization efficiency is expected to be higher than the measured value because the internal volume of the shoe rack was smaller than the test chamber used to measure the deodorization efficiency. The deodorization effect could be increased further by the sterilization of bacteria causing bad odors in shoes. Further studies will be needed to determine the temperature deviations within the shoe rack to provide constant conditions.
Choe, Su Bin;Han, Sang Jin;Han, Ouk Hee;Kim, Hak Su;Kang, Sung Tae
Journal of the Korean Society of Food Science and Nutrition
/
v.42
no.1
/
pp.148-152
/
2013
An ultraviolet (UV) sterilization system was developed to decrease the number of microorganisms in filtered Acer mono sap (FAS). The Acer mono sap (AS) was passed through 18 strips of PTA fluoroplastic tubing with 30 UV lamps (total 1,170 W). During passage, the AS was effectively exposed to the UV rays. The total bacteria, coliform group and fungi were sterilized at a flow rate ranging from 852 to 1,358 mL/min and a UV power higher than 156 W. Although the sensory score of the UV-sterilized AS was significantly lower than that of the untreated AS, the sensory score was better under the condition of 390 W and 852~1,358 mL/min than under the other conditions examined. ANOVA did not reveal a significant difference in pH, total acidity, sugar content and color characteristic under all conditions tested (p<0.05). Considering the overall attributes of the AS quality, the optimum sterilization condition was determined to be 390 W and 852~1,358 mL/min.
Sung, Su-Jin;Huh, Jung-Bo;Yun, Mi-Jung;Chang, Brian Myung W.;Jeong, Chang-Mo;Jeon, Young-Chan
The Journal of Advanced Prosthodontics
/
v.5
no.1
/
pp.2-8
/
2013
PURPOSE. Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated. MATERIALS AND METHODS. After inoculating E. coli and B. subtilis the diamond burs and polyvinyl siloxane materials were sterilized by exposing them to the plasma for different lengths of time (30, 60, 90, 120, 180 and, 240 seconds). The diamond burs and polyvinyl siloxane materials were immersed in PBS solutions, cultured on agar plates and quantified by counting the colony forming units. The data were analyzed using one-way ANOVA and significance was assessed by the LSD post hoc test (${\alpha}$=0.05). RESULTS. The device was effective in killing E. coli contained in the plasma device compared with the UV sterilizer. The atmospheric pressure non-thermal air plasma device contributed greatly to the sterilization of diamond burs and polyvinyl siloxane materials inoculated with E. coli and B. subtilis. Diamond burs and polyvinyl siloxane materials inoculated with E. coli was effective after 60 and 90 seconds. The diamond burs and polyvinyl siloxane materials inoculated with B. subtilis was effective after 120 and 180 seconds. CONCLUSION. The atmospheric pressure non-thermal air plasma device was effective in killing both E. coli and B. subtilis, and was more effective in killing E. coli than the UV sterilizer.
Park, Seul-Ki;Lee, Da-eun;Jo, Du-Min;Song, Mi-Ru;Kim, Young-Mog
Microbiology and Biotechnology Letters
/
v.50
no.1
/
pp.95-101
/
2022
Due to the pandemic caused by COVID-19, the demand for face masks is soaring and has often caused a shortage. The aim of this study was to evaluate the effect of ultraviolet (UV) and drying treatments on microbial contaminants in facial masks. To conduct this study, standard procedures were designed to develop samples contaminated by the control bacteria Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The contamination level of the standard samples was approximately 6.30 × 106 CFU/ml, and the UV light treatment was performed 1, 3, 5, and 7 times. To evaluate the effect of the UV and drying treatments, the masks were first treated with UV 1, 2, and 3 times, followed by the drying process. As a result, the mask contaminated with E. coli and P. aeruginosa showed a bacterial rate of approximately 99.9% after 1 UV irradiation, and in the case of the S. aureus-contaminated mask, it exhibited a bactericidal rate of approximately 99.9% after 7 UV irradiations. However, when the drying process was included after UV irradiation, all the samples contaminated with E. coli, S. aureus, and P. aeruginosa showed a bactericidal rate of 99.9% or more. The results of this study suggest that UV and drying treatments can effectively reduce the bacterial contaminants in facial masks. In addition, these results provide fundamental data and appropriate sterilization methods for reusing masks.
There has been increasing awareness on the importance of not only removal of organic materials but also sterilization of microbial cell in the drinking water purification research, so there has been many researches on that area. This study has been designed to analyze the effects of $TiO_{2}$ and ZnO coated on activated carbon on Escherichia coli. In this study, the sterilization power was analyzed by (1) variation of $TiO_{2}$ and ZnO concentration coated on activated carbon (2) variation of UV intensity. In addition, the kinetics between exposure time and sterilization velocity was viewed by the method of Chick. The results are as follows. 1. Survival ratio of E. coli decreased as time goes on in application of $TiO_{2}$, ZnO and $TiO_{2}{\cdot}ZnO$. In $TiO_{2}$ and ZnO, the effect increased upto certain concentration, but decreased there-after. In $TiO_{2}{\cdot}ZnO$, the effect of sterilization was in similar way among 3 combinations. 2. Survival ratio of E. coli decreased proportionately to an increase of light intensity in ZnO and $TiO_{2}{\cdit}ZnO$. In $TiO_{2}$, the survival ratio differed over extent of irradiation but the difference over the light intensity was not significant. 3. When Chick's law of sterilization was applied, m values of three concentrations of $TiO_{2}$ were 1.57,0.98, 1.96 respectively. M values of three concentration of ZnO were 1.10, 1.18,0. 11 respectively and those of three combination of $TiO_{2}{\cdot}ZnO$ were 1.17, 1.24, 1.74 respectively.
The Transactions of The Korean Institute of Electrical Engineers
/
v.58
no.3
/
pp.559-565
/
2009
In this paper, we invented a new and unique technique for the sterilization of Escherichia coli(E. coli) in polluted water. We applied a rich ultra-violet(UV) light from pulsed xenon flashlamp and photocatalyst(TiO2) to sterilize E. coli in polluted water. This method based on the use of UV light and photocatalyst is eco-friendly and does not cause secondary pollution. The proposed elliptical reactor is able to concentrate on quartz sleeve coated TiO2 or general quartz sleeve. The primary objective of our research was to determine the important parameters such as pulse repetition rate and input voltage and to know on the sterilizing efficiency of quartz sleeve coated TiO2 and general quartz sleeve. We obtained to achieve 99.999% sterilization in as little as 6 pulses at 800V in case of quartz sleeve coated Ti02, and 10 pulses at 800V in case of general quartz sleeve for 5 minutes. Although transmitted light of quartz sleeve coated TiO2 is deceased, the sterilizing efficiency is increased by 40% than general quartz sleeve. The reason of high sterilizing efficiency is that generated hydroxyl radical(OH) by photocatalyst and is able to concentrate light at a focus by using elliptical reactor.
Journal of the Korea Academia-Industrial cooperation Society
/
v.12
no.11
/
pp.4924-4931
/
2011
This research performed to evaluate a production processes reporting by the HACCP system of green vegetable juice products, containing lactic acid bacteria, stage of processing raw materials agricultural products and production facilities of general bacteria and pathogenic micro organism. General bacteria are found from four samples of storage of agricultural products at process stage and water was detected 8.67~14.67 CFU/ml. However, all samples were detected less than 105 CFU/ml as a legal standards after the process of UV sterilization. For the outcome of experiment of E.coli, E.coli O157:H7, B.cereus, L.moonocytogenes, Salmonella spp, Staph.aureus as the food poisoning bacterial, E.coli was detected until UV pre-step process in storage process and B.cereus was detected partly till 1st washing. Since all bacterial, Yeast and Mold are detected in main materials, pre-control method is a necessary to establish for decreasing with a number of initial bacteria of main materials and it is considered to establish the effective ways of washing and sterilization such as production facilities for cross contamination prevention of bacteria and Sthaphylococcus. Based on above results, the process of UV sterilization should be managed with CCP as an important process to reduce or eliminate the general and food poisoning bacterial of green vegetable juice products, including lactic acid bacteria. Therefore, it is considered to need an exhaustive HACCP plan such as control manual of UV sterilization, solution method, verification, education and training and record management.
UV disinfection system allows the disinfection of municipal and industrial water and wastewater without the use of expensive chlorination and dechlorination techniques, labor intensive equipments In traditional ultraviolet systems the UV lamps are seperated from water by quartz sleeves. quartz is one of. the few materials that is virtually transparent to UV light, the UV lamp is placed inside the Quartz sleeve. UV light from the lamp is passed through the quartz and into the water, thereby providing disinfection. In fluoropolymer tube-used non-contact UV systems, the water flows through fluoropolymer plastic tubes. banks of UV lamps surround these tubes such that each tube gets exposed to ultra violet light from all sides. in non-contact design the lamps operates at almost constant temperature. this design is extremly efficient in the utilization of UV energy and superior to conventional contact- systems.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.