• 제목/요약/키워드: UV fluorescence

검색결과 325건 처리시간 0.042초

Intrinsic UV Reflection and Fluorescence Studies for Water Sorption in Polycarbonate, Polyurethane and Poly(Ethylene Terephthalate) Films

  • Kim Min Sun;Sung Chong Sook Paik
    • Fibers and Polymers
    • /
    • 제6권2호
    • /
    • pp.127-130
    • /
    • 2005
  • Intrinsic UV reflection and fluorescence behaviors of polycarbonate, polyurethane and poly(ethylene terephthalate) films were investigated in order to characterize the interaction of water in these films. During water sorption process, UV reflection spectra of polycarbonate and polyurethane films showed little peak position changes. Fluorescence emission spectra of polycarbonate films showed red spectral shifts from 332 nm with water immersion time. This red-shifted peak could be due to phenyl-2-phenoxybenzoate, which is one of the major thermal degradation products in polycarbonate. Fluorescence peaks of polyurethane films appeared at two different positions and the ratio of these peak intensities increased with increasing immersion time. In the case of PET films, the UV reflection spectrum showed the peak intensity around 340 nm to change in response to water sorption. The fluorescence near 388 nm probably due to ground state dimer exhibited sensitivity with water sorption, when excited at 340 nm.

자외선 유도 형광의 사과 성숙도 평가 적용 (UV/blue Light-induced Fluorescence for Assessing Apple Quality)

  • 노현권
    • Journal of Biosystems Engineering
    • /
    • 제35권2호
    • /
    • pp.124-131
    • /
    • 2010
  • Chlorophyll fluorescence has been researched for assessing fruit post-harvest quality and condition. The objective of this preliminary research was to investigate the potential of fluorescence spectroscopy for measuring apple fruit quality. Ultraviolet (UV) and blue light was used as an excitation source for inducing fluorescence in apples. Fluorescence spectra were measured from 'Golden Delicious' (GD) and 'Red Delicious' (RD) apples using a visible/near-infrared spectrometer after one, three, and five minutes of continuous UV/blue light illumination. Standard destructive tests were performed to measure fruit firmness, skin and flesh color, soluble solids and acid content from the apples. Calibration models for each of the three illumination time periods were developed to predict fruit quality indexes. The results showed that fluorescence emission decreased steadily during the first three minutes of UV/blue light illumination and was stable within five minutes. The differences were minimal in the model prediction results based on fluorescence data at one, three or five minutes of illumination. Overall, better predictions were obtained for apple skin chroma and hue and flesh hue with values for the correlation coefficient of validation between 0.80 and 0.90 for both GD and RD. Relatively poor predictions were obtained for fruit firmness, soluble solids content, titrational acid, and flesh chroma. This research has demonstrated that fluorescence spectroscopy is potentially useful for assessing selected quality attributes of apple fruit and further research is needed to improve fluorescence measurements so that better predictions of fruit quality can be achieved.

UV 광풍화에 의한 미세플라스틱 기원 유기물 용출과 형광 특성: 자연유래 유기성 입자와의 비교 (Dissolved Organic Matter (DOM) Leaching from Microplastics under UV-Irradiation and Its Fluorescence P roperties: Comparison with Natural P articles)

  • 최나은;이윤경;허진
    • 한국물환경학회지
    • /
    • 제38권2호
    • /
    • pp.72-81
    • /
    • 2022
  • Numerous studies have investigated the occurrence and fate of microplastics in the environment; however, only limited effort has been devoted to exploring the characteristics of dissolved organic matter (DOM) leached from microplastics. In microplastic (MP)-contaminated environment, MPs are typically mixed with naturally-occurring particles, which interferes with their detection in the environment. Thus, it is necessary to distinguish between the DOM leached from MPs and those leached from natural particles and also to characterize their properties. This study investigated DOM leaching behavior from MPs (polystyrene: PS, polyvinylchloride: PVC) and natural particulates (forest soil: FS, litter leaves: LL) under light, which is considered one of the main weathering processes that affect MPs in the environment. The leached DOM concentrations and fluorescence characteristics were compared under dark versus light conditions. Regardless of the origins, UV light promoted DOM release from all the particulates. More DOM was released from natural particles than from MPs under both conditions. However, the effect of promoting DOM release by UV was more pronounced for MPs than for natural particles. It was observed from fluorescence spectra that the intensity of the humic-like region was substantially reduced when MP-derived DOM was exposed to UV light, whereas the change of intensity was very little for natural particles. Under light conditions, the ratio of protein-like to humic-like fluorescence of MP-derived DOM was higher than that of DOM from natural particles. This study implies that a substantial amount of DOM could be leached from MPs even in MP-polluted environment under UV irradiation. Protein/humic fluorescence ratio could be utilized as a fast probing indicator to separate the two sources of particles under light.

하천 분광특성을 이용한 수질항목 모니터링 연구 - 울산 지역 (Monitoring of Water Quality Parameters using Spectroscopic Characteristics of River Water - Ulsan Area)

  • 허진;김미경;신재기
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.863-871
    • /
    • 2007
  • Spectroscopic characteristics of river water from four major watersheds in the Ulsan area were measured to examine their potential for estimating water quality parameters. The total 176 river samples were collected from 44 sites of small streams within the watersheds during the year 2006. Spectroscopic characteristics investigated included protein-like fluorescence (FLF) intensity, fulvic-like fluorescence (FLF) intensity, terrestrial humic-like fluorescence (TLF) intensity, UV absorbance at 254 nm, and UV absorbance difference at 220 nm and 254 nm. Protein-like fluorescence intensity showed linear relationships with biochemical oxygen demand (BOD), chemical oxygen demand (COD), total phosphorous (TP) concentrations of the samples with the correlation of 0.784, 0.779, and 0.733, respectively. Due to the UV absorption characteristics of nitrate at 220 nm, UV absorbance difference at 220 nm and 254 nm was selected to represent total nitrogen (TN) concentration. Exclusion of some samples with PLF intensity higher than 5.0 improved the correlation between the UV absorbance difference and TN as demonstrated by the increase of the correlation coefficient from 0.392 to 0.784. Instead, for the samples with PLF intensity lower than 5.0, the highest correlation of TN was achieved with UV absorbance at 254 nm. The results suggest that PLF intensity could be used as the estimation index for BOD, COD, and TP concentration of river water, and as the primary screening index for the prediction of TN using UV absorbance difference. Some BOD-based water quality levels among the river water were statistically discriminated by the PLF intensity. Low p-values were obtained from the t-tests on the samples with the first level and the second level (p=0.0003) and the samples with the second and the third levels (p=0.0413). Our combined results demonstrated that the selected spectroscopic characteristics of river water could be utilized as a tool for on-site real-time monitoring and/or the primary estimation of water quality.

Spectroscopic Studies on the Oxidation of Catechin in Aqueous Solution

  • Bark, Ki-Min;Yeom, Ji-Eun;Yang, Jeong-Im;Yang, Ik-Jun;Park, Chul-Ho;Park, Hyoung-Ryun
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권9호
    • /
    • pp.3443-3447
    • /
    • 2011
  • The spectroscopic behavior of catechin (5,7,3',4'-tetrahydroxyflavan-3-ol), has been studied in the presence and the absence of air using UV-vis absorption spectrophotometry and fluorescence spectroscopy. The UV-vis absorption spectrum of catechin shows a very sharp and strong absorption maximum peak at 275 nm in deaerated water. New absorption maximum peaks appeared in aerated water, as well as in basic aqueous solution, caused by the oxidation of catechin. The absorbances in the UV-vis absorption spectrum of catechin decreased when the solution was left in the dark for a long time. The fluorescence emission spectrum of catechin after a long time period differs markedly from that in freshly prepared solution; the fluorescence maxia shifted as time passes after adding catechin to the solutions. When the deaerated basic catechin solutions were left in the dark for a long time, their fluorescence quantum yields were found to be nearly zero. This suggests that the oxidized catechin molecules were seen to have slowly undergone successive chemical reactions in basic buffer solution.

Quinine Assay with Home-Built UV-LED Fluorometer: Quantitative Analysis, Photo-Bleaching, Fluorescence Quenching, and Urine Analysis

  • Cheon, Tae-Min;Cheong, Byeong-Seo;Cho, Han-Gook;Kim, Jin-Hee;Kim, Kyoug-Soo
    • 대한화학회지
    • /
    • 제56권5호
    • /
    • pp.577-582
    • /
    • 2012
  • Quinine quantitative analysis, photo-bleaching, fluorescence quenching, and urine analysis have been performed by means of a UV-LED fluorometer, which can be easily built and used in a high-school laboratory. The quinine detection range is estimated to be 0.05-80 ppm, enough for many classroom luminescence experiments. The quinine content in commercial tonic water is determined from the calibration curve, and UV photo-bleaching of this anti-malarial drug is demonstrated with clear wavelength dependence. Halide quenching of quinine fluorescence is also observed and the increase in quenching efficiency in the order of $Cl^-$, $Br^-$, and $I^-$ is evident. Urine analyses for the student volunteers have been carried out and the results clearly reveal excretion of the ingested quinine. The student participants are exuberant throughout the course of this study and sense the practices resourceful.

Drug-Biomacromolecule Interaction XII: Comparative binding study of sulfaethidole to bovine serum albumin by equilibrium dialysis, fluorescence probe technique, uv difference spectrophotometry and circular dichroism

  • Kim, Chong-Kook;Chun, Yang-Sook;Lah, Woon-Lyong
    • Archives of Pharmacal Research
    • /
    • 제12권3호
    • /
    • pp.160-165
    • /
    • 1989
  • Binding of sulfaethidole to bovine serum albumin was studied by equilibrium dialysis, fluorescence probe technique, uv difference spectrophotometry and circular dichroism. Equilibrium dialysis method enabled us to estimate the total number of drug binding sites of albumin molecule. For sulfaethidole, albumin had 6 primary and 40 secondary binding sites. The primary and secondary binding constants were 0.9 * 10/sup 5/ M/sup -1/ and 0.2 * 10/sup 6/ M/sup -1/, respectivitely. 1-Anilino-8-naphthalenesulfonate (ANS) and 2-(4-hydroxylbenzeneazo)- benzoic acid (HBAB) were used as the fluorescence probe and the uv spectrophotometric probe, respectively. In fluorescence probe technique, results indicated that the number of higher affinity drug binding site of albumin was 1 and the number of lower affinity drug binding sites of albumin was 3, and the primary and secondary drug binding constants for bovine serum albumin were 2.15 * 10/sup 5/M/sup -1/ and 1.04 * 10/sup 5/ M/sup -1/, respectively. In uv difference spectrophotometry, binding sites were 3 and binding constant was 1.88 * 10/sup 5/M/sup -1/. The above spectrophotometry, binding sites were 3 and binding constant was 1.88 * 10/sup 5/M/sup -1/. The above results suggest that several different methods should be used in ompensation for insufficient information about drug binding to albumin molecule given by only one method.

  • PDF

박테리오파지 f2에 대한 자외광선의 살균효과 (The Inactivation Effects of UV Light on Bacteriophage f2)

  • Kim, Chi-Kyung;Quae Chae
    • 한국미생물·생명공학회지
    • /
    • 제11권3호
    • /
    • pp.155-161
    • /
    • 1983
  • Bacteriophage f2에 대한 자외광선의 살균효과와 외투막 단백질의 구조에 미치는 영향을 Ray-onet photoreactor PPR-208을 사용하여 300nm의 광선으로 연구하였다. 처음 20분간의 조사에서는 약 4 log의 phage가 감소되고 그후 완만한 살균효과를 보이다가 90분 이상의 조사에서는 생존 바이러스가 발견되지 않았다. Tryptophan residue의 fluorescenve quenching, 자외선으로 조신한 phage에 부착시킨 ANS (8-anilino-1-napht-halene sulfonate)의 fluorescence emission의 감소, tryptophan에서 ANS로의 energy transfer 의 감소 등 spectroscopic technique에 의한 결과와 자외선 조사에 의하여 단백질 외투만이 파손되는 전자현미경 관찰의 결과에 의하여 자외광선은 phage f2의 외투막 단백질의 구조에 변화를 일으킨다는 것이 밝혀졌다.

  • PDF

HPLC에 의한 aflatoxin 분석법에 관한 연구 형광 및 자외선 흡광 검출의 비교 (Determination of Aflatoxins Using High-Performance Liquid Chromatography and Fluorescence or UV Absorbence Detection)

  • 김종규;강회양;민경진
    • 한국환경보건학회지
    • /
    • 제22권1호
    • /
    • pp.36-44
    • /
    • 1996
  • A comparison was made of two detection methods(UV absorbence detection and fluorescence detection with pre-column derivatization, with trifluoroacetic acid) coupled with HPLC for the simultaneous determination of aflatoxin $B_1, B_2, G_1$ and $G_2$. A good separation of the four aflatoxins was achieved on a reversed-phase $C_{18}$ column (30 cm x 3.9 mm) with methanol-acetonitrile-water(20+20+60) for absorbence detection or acetonitrile-water(25+75) for fluorescence detection at the flow rate of 1.0 ml/min. The calibration graphs were linear over the ranges 100 ppb-1 ppm for $B_1/G_1$ and 30~300 ppb for $B_2/G_1$ with absorbence detection, and 1~500 ppb for $B_1/G_1$ and 0.3~150 ppb for $B_2/G_2$ with fluorescence detection. The correlation coefficients were greater than 0.94 and 0.99 for absorbance detection and for fluorescence detection, respectively. The detection limit was 100 ng for $B_1/G_1$ and 30 ng for $B_2/G_2$ with absorbence detection, and 1 ng for $B_1/G_1$ and 0.3 ng for $B_2/G_2$ with fluorescence detection. Recovery rates of aflatoxin $B_1, B_2, G_1$ and $G_2$ added to yeast-extract sucrose broth medium were 66.6%, 59.4%, 67.5% and 59.2%, respectively, for absorbence detection and 82.9%, 71.5%, 80.0% and 69.3%, respectively, for fluorescence detection. The four aflatoxins in culture medium were quantitatively detected by the two methods. The aflatoxins in the rice sample were not detected the absorbence detection method, but were below 10 ppb using the fluorescence detection method. Analysis of aflatoxins by both the absorbence and fluorescence methods coupled with HPLC showed acceptable linearity and good recovery. The absorbence detection was less timeconsuming and safer for treatment. The fluorescence detection was more elective and sensitive though elevated $B_1$ and $G_1$ contents were determined from the TFA-induced conversion of $B_1$ to $B_{2a}$ and $G_1$ to $G_{2a}$.

  • PDF