• 제목/요약/키워드: UV dose

검색결과 350건 처리시간 0.026초

CFD에 의한 Axial Reactor Type 자외선 유수살균장치의 출구 위치에 따른 UV Dose 예측 (UV Dose Predictions for Ultra Violet Flowing Water Purification of Axial Reactor Type based on the location of the exit by CFD)

  • 최종웅;김성수;박노석;이영주;채선하
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.521-533
    • /
    • 2012
  • Interest in application of ultraviolet light technology for primary disinfection that used for the treatment of water for consumption and wastewater has increased significantly in recent years. Analysis of these systems has been carried out using Computational Fluid Dynamics (CFD) procedure. It offers advantages over other techniques in specific circumstances. CFD has emerged as a powerful tool to aid design of a UV reactor by providing the UV dose delivered by the proposed reactor design and allowing engineers to evaluate alternative designs in much less time and at a reasonable cost. In this study, five different configurations of the apparatus depending on the location of the exit are evaluated in terms of maximum dose, minimum dose, flow patterns, particle tracks and transient dose. The configuration 3 results have higher minimum UV dose value and uniform particle distribution of the UV dose on the outlet than other's.

Dose-dependent UV Stabilization of p53 in Cultured Human Cells Undergoing Apoptosis Is Mediated by Poly(ADP-ribosyl)ation

  • Won, Jungyeon;Chung, So Young;Kim, Seung Beom;Byun, Boo Hyeong;Yoon, Yoo Sik;Joe, Cheol O.
    • Molecules and Cells
    • /
    • 제21권2호
    • /
    • pp.218-223
    • /
    • 2006
  • The effect of poly(ADP-ribosyl)ation on the stability of p53 in SK-HEP1 cells treated with UV light was examined. Intracellular levels of p53 increased in cells treated with a low dose of UV light ($20J/m^2$), whereas they increased but then declined after a higher dose of UV ($100J/m^2$). Intracellular levels of p53 in the UV treated SK-HEP1 cells were dependent on the UV dose. Use of proteasome inhibitors revealed that p53 is degraded by proteasomal proteolysis after high doses of UV light. We present evidence that, at low doses, poly(ADP-ribose)polymerase (PARP) poly(ADP-ribosyl) ates p53 and protects it from proteasomal degradation before caspase-3 is activated, whereas at high doses the cells undergo UV induced apoptosis and PARP is cleaved by caspase-3 before it can protect p53 from degradation. Destabilization of p53 by cleavage of PARP may be important in cell fate decision favoring apoptosis.

Solar Ultraviolet Irradiance Incident on a Horizontal Surface At taegu In Korea During 1995-1998 : (I) Ultraviolet -A

  • Suh, Kye-Hong
    • Journal of Photoscience
    • /
    • 제6권1호
    • /
    • pp.1-3
    • /
    • 1999
  • Solar ultraviolet-A (UV-A) irradiances indicent on a horizontal surface at Taegu of Korea during 1995-1998 were calculated with 5 min averages of measurements taken every 30 seconds by a broadband UV- A sensor. The maximum and minimum of monthly averages of daily UV-A dose were 499.37 KJ m-2 day-1 inJuly and 171.09 KJ m--2 day-1 in December for 4 years of the observation period. The maxima of daily UV-A dose and instandaneous UV-A were observed as 846.46KJ m-2 day-1 June 7, 1998 and 37.22 W m-2 at 12 : 15, July 16, 1998, respectively. Increasing trends in annual maxima of daily UV-A dose and instantaneous UV-A were averaged to 6.4% and 6.7% , respectively, per year during 1995-1998 at Taegu, Korea.

  • PDF

광-펜톤 산화반응을 이용한 Rhodamine B의 탈색 (Decolorization of Rhodamine B by Photo-Fenton Oxidation)

  • 박영식
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.274-280
    • /
    • 2007
  • The photochemical decolorization of Rhodamine B (RhB) in water has been carried out by photo-Fenton process. The effect of applied $H_2O_2$, $Fe^{2+}$ dose, solution pH and UV dose have been studied. The influence of constituent processes of photo-Fenton such as UV, $H_2O_2$ and Fenton has been investigated. Comparison of RhB removal was made between the photo-Fenton and $UV/H_2O_2$ process. The results obtained showed that the optimum dosage of $Fe^{2+}$ and $H_2O_2$ were 0.0031 mmol and 0.625 mol, respectively. pH 3 is found to be the optimum pH of for photo-Fenton process. pH and UV dose strongly influenced the decolorization of RhB in photo-Fenton process. The photo-Fenton and $UV/H_2O_2$ processes showed similar decolorization and seem to be appropriate for the decolorization of dye wastewater.

Disinfection and Reactivation of Microorganisms after UV Irradiation for Agricultural Water Reuse of Biofilter Effluent

  • Jung, Kwang-Wook;Yoon, Chun-G.;Hwang, Ha-Sun;Ham, Jong-Hwa
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.94-106
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of UV disinfection system and the reactivation of indicator microorganisms (TC, FC, E. coli) after UV irradiation for agricultural reuse of reclaimed water. Photoreactivation and dark repair enable UV-inactivated microorganisms to recover and may reduce the efficacy of UV inactivation, which might be drawbacks of the UV disinfection method. The effluent of biofilter for 16-unit apartment house was used as input to the UV disinfection system, and average SS and BOD concentration were 3.8 and 5.7 mg/L, respectively, and the mean level of total coliform was in the range of $1.0\times10^4$ MPN/100mL. UV disinfection was found to be effective and it reduced mean concentration of indicator microorganisms (total coliform, fecal coliform, and E. coli) to less than 100 MPN/100mL within 60s exposure using 17, 25, and 40W lamps. Two UV doses of 6 and 16 mW$\cdot$s/$\textrm{km}^2$ were applied and microorganisms reactivation was monitored under the dark, photoreactivating light, and solar irradiation. Microorganisms reactivation was observed in the UV dose of 6 mW$\cdot$s/$\textrm{km}^2$, and numbers increased up to 5% at the photoreactivating light and 1% at the dark. However, microorganisms were inactivated rather than reactivated at the solar radiation and numbers decreased to non-detectible level about below 2 MPN/100mL in 4 hours. In the case of 16 mW$\cdot$s/$\textrm{km}^2$, microorganism reactivation was not observed indicating that UV dose might affect the reactivation process such as photoreactivation and dark repair. Therefore, concerns associated with microorganism reactivation could be controlled by sufficient UV dose application. Agricultural reuse of reclaimed water might be even less concerned due to exposure to the solar irradiation that could further inactivate microorganisms. The pilot study result is encouraging, however, sanitary concern in water reuse is so critical that more comprehensive investigation is recommended.

UV/H2O2 고도산화기술을 이용한 수중 잔류의약물질 제거 (Degradation of residual pharmaceuticals in water by UV/H2O2 advanced oxidation process)

  • 박진영;서상원;조익환;전용성;하현섭;황태문
    • 상하수도학회지
    • /
    • 제33권6호
    • /
    • pp.469-480
    • /
    • 2019
  • This study was conducted to evaluate the degradation and mineralization of PPCPs (Pharmaceuticals and Personal Care Products) using a CBD(Collimated Beam Device) of UV/H2O2 advanced oxidation process. The decomposition rate of each substance was regarded as the first reaction rate to the ultraviolet irradiation dose. The decomposition rate constants for PPCPs were determined by the concentration of hydrogen peroxide and ultraviolet irradiation intensity. If the decomposition rate constant is large, the PPCPs concentration decreases rapidly. According to the decomposition rate constant, chlortetracycline and sulfamethoxazole are expected to be sufficiently removed by UV irradiation only without the addition of hydrogen peroxide. In the case of carbamazepine, however, very high UV dose was required in the absence of hydrogen peroxide. Other PPCPs required an appropriate concentration of hydrogen peroxide and ultraviolet irradiation intensity. The UV dose required to remove 90% of each PPCPs using the degradation rate constant can be calculated according to the concentration of hydrogen peroxide in each sample. Using this reaction rate, the optimum UV dose and hydrogen peroxide concentration for achieving the target removal rate can be obtained by the target PPCPs and water properties. It can be a necessary data to establish design and operating conditions such as UV lamp type, quantity and hydrogen peroxide concentration depending on the residence time for the most economical operation.

항 방사선 인삼단백분획의 DNA수복능력 증진효과 (DNA Repair Enhancement by Radioprotective Ginseng Protein Fraction)

  • 김춘미;최미경
    • 약학회지
    • /
    • 제36권5호
    • /
    • pp.449-454
    • /
    • 1992
  • The effect of radioprotective ginseng protein fraction on DNA repair capacity was determined by measuring the amount of $^{3}H-thymidine$ incorporated into DNA in the process of repair synthesis for UV damaged DNA. CHO-Kl cells were prepared whose semiconservative replication was inhibited by trimethylpsoralen plus near-UV(PUVA) treatment. When the cells were exposed to UV light alone, the DNA repair capacity was increased at first and then decreased as UV dose increased. However, when the ginseng fraction was treated to the cells, the DNA repair capacity was kept increasing regardless of UV dose increment. When the concentration of protein contained in the added fraction was increased gradually, the repair capacity was also increased almost linearly showing dose-response relationship of the effect. These results suggest that the enhancement of DNA repair capacity of the cell can be one of the mechanisms of radioprotection by the ginseng fraction.

  • PDF

UV 챔버 내부 온도 및 체류시간이 Urethane Acrylate의 경화속도에 미치는 영향 (The Effect of Temperature and Exposure Time on UV-curing of Urethane Acrylate)

  • 문승호;김광희;김정식
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.3822-3826
    • /
    • 2012
  • 소형 UV 챔버 내부온도 및 챔버 내 체류시간이 Urethane Acrylate 의 경화속도에 미치는 영향을 조사하였다. UV 램프에 가해지는 Power를 60, 80, 100% 로 조절하여 UV 조사량 (UV dose)를 변경하였고 필름이 지나가는 챔버 내부의 가이드롤 (또는 패턴롤)에 냉각수를 투입하여 롤 자체의 온도에 변화를 주었다. 또한 코팅속도를 조절하여 챔버 내부에서의 체류 시간을 변경시켰는데 이들 조건들이 Urethane Acrylate 의 경화에 어떠한 영향을 미치는지를 알아보기 위하여 경화된 필름의 gel 분율을 측정, 비교하였다. 본 연구를 통해 Power가 증가 할수록 경화기 내부의 온도는 상승 하였으며 냉각수 투입에 따라 경화기 내부의 온도는 감소하였는데 이러한 경화기 내부의 온도변화는 UV 경화에 큰 영향을 미치지 않음을 알 수 있었다. 반면에 코팅속도가 증가할수록 경화필름의 gel 분율은 감소하였는데 이는 충분한 경화를 위해서는 경화기내부에서의 체류시간이 일정 이상이 되어야 함을 의미하였다. 한편, 체류시간에 따른 UV dose 측정 및 UV 램프주변의 열유동 해석을 통하여 램프주변의 온도분포 해석을 시도하였는데 이러한 결과들을 바탕으로 UV 경화기 구조 및 운전 조건이 UV 경화된 제품의 특성에 어떠한 영향을 미치는지 알 수 있었다.

염소주입량과 반응시간에 따른 HAAs 생성과 고도산화처리에 의한 전구물질 제거 영향 (HAAs Formation by Chlorine Dose and Reaction Time and The Removal Effect of Precursors by The Advanced Oxidation Processes)

  • 김경숙;오병수;주설;강준원
    • 한국물환경학회지
    • /
    • 제20권2호
    • /
    • pp.145-150
    • /
    • 2004
  • This study investigated the effect of chlorine dose and chlorine reaction time for the formation of haloacetic acids (HAAs). According to the results, HAA formation was highly affected by chlorine dose and chlorine reaction time. HAA formation reached a plateau value at 30 mg/L of chlorine dose and 24 hr of chlorine reaction time. For the speciation of formed HAAs in the test water, the concentration of brominated-HAAs was significantly lower than that of chlorinated-HAAs because of low level of bromide ion concentration in the test water. It also investigated the removal efficiency of HAA precursors by several unit processes, such as ozone alone, UV alone, and combined ozone/UV system. Of them, ozone/UV system was proved as the best process to control the HAAs formation. The increase of the brominated-HAAs was observed during ozonation with and without UV irradiation showing the slight increase of total HAA concentrations.

Relationship between Stratospheric Ozone and Solar Ultraviolet B Irradiance in Taegu, Korea

  • Suh, Kye-Hong;Cho, Young-Joon
    • The Korean Journal of Ecology
    • /
    • 제24권2호
    • /
    • pp.117-119
    • /
    • 2001
  • Solar ultraviolet-B (UV-B) irradiances incident on a horizontal surface at Taegu, Korea during 1996-1998 were calculated with 5 minute averages of measurements taken every 30 seconds by a broadband UV-B sensor. The average, maximum and minimum of daily UV-B dose were 11.31, 22.04 and 3.20kJ m$^{-2}$ day$^{-1}$ , respectively, for the measuring period. Variations in stratospheric ozone concentration measured from space explain 85% of changes in the daily UV-B dose. It was expected that decrease of 50 Du in stratospheric ozone cause increase of 24.1% in daily UV-B dose in this study.

  • PDF