• 제목/요약/키워드: UV disinfection system

검색결과 45건 처리시간 0.026초

자외선 강도 산정 모델과 영향 인자에 관한 연구 (A Study on the UV Intensity Models and their Affecting Factors)

  • 김두일;최영균;김성홍
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.421-427
    • /
    • 2008
  • UV disinfection is widely used in water treatment facilities and wastewater treatment plant because of its effectiveness to removal of pathogen and Giardia which is resistant to traditional chemical disinfection. As a design and performance tool of UV disinfection system, 3 dimensional UV intensity models were composed and simulated to compare each other and to find affecting factors in this study. Reflection, refraction and absorption are important parameters in UV intensity model and MPSS and MSSS model can reflect these parameters while LSI model can not. Absorption is the most important parameters among the reflection, refraction, absorption and shadowing so, this should not be neglect. Based on this simulation, shadowing effect is negligible when the number of installed lamp is a few but, this effect can not be neglectable when the number of installed lamp is quite a few. The errors according to shadowing effect is increased as the number of lamp installed increased.

비접촉식 자외선 광반응조를 이용한 하수 대장균의 살균과 Log 불활성화율 지표 (Disinfection of E. coli from Wastewater using a Non-contact type UV Photoreactor and Log Inactivation Index)

  • 김성홍;김경면;김광일;최재완
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.139-145
    • /
    • 2016
  • Disinfection of microorganisms using UV light is widely used in the field of water supply and wastewater treatment plant, In spite of high germicidal effect and relatively clean by-product, UV disinfection has fundamental defeat that is accumulation of fouling materials at the interface of water and lamp sleeve. Non-contact type of UV photoreactor which can avoid this fouling generation was developed and the experimental performance evaluation of the system was carried out in this study. Log inactivation rate of E. coli was selected as a disinfection index. The concentration of E. coli of second clarifier effluent was $8.2{\times}10^1-8.2{\times}10^3$ colony per mL and was well inactivated by the non-contact type of UV photoreactor. Under the UV intensity condition of $2.1-2.5mW/cm^2$, E. coli removal rate was observed in the range of 54 - 95% when the HRT was increased from 10 to 52 seconds. Experimental results showed that log inactivation of E. coli was proportional to UV dosage and $200mJ/cm^2$ of UV dose is expected for the 2.0 log inactivation of E. coli from the second clarifier effluent. Between the two parameters of UV intensity and contact time which are consist of UV dose, UV intensity was 4 times more effective than contact time.

자외선램프를 이용한 선박평형수 처리시스템의 설계 및 제작 (Design and Fabrication of a Ballast Water Treatment System Using UV Lamps)

  • 표태성;천상규;박대원;최성국;김성연;길경석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.952-958
    • /
    • 2009
  • The International Maritime Organization (IMO) has adopted the ballast water management convention at a diplomatic conference in early 2004 that all ships should be equipped with a treatment system from 2010 gradually. In this paper, the disinfection characteristic of ultra-violet (UV) rays was studied and a ballast water treatment system (BWTS) which can treat $50m^3$/h sea water was manufactured. The system consists of a disinfection chamber with six 3.5 kW UV lamps which are operated by magnetic ballasts, a programmable logic controller (PLC) and set of pipe lines. The biological disinfection efficacy of the prototype BWTS was evaluated following the IMO rules using zooplankton such as Artemia and Rotifer species for the size over $50{\mu}m$, and phytoplankton such as Tetraselmis and Thalassiosira species for the size between 10 to $50{\mu}m$. From the experimental results, the disinfection efficacy was 99.99 % that meets the IMO requirement. However, more studies on an energy saving system are needed because the consumption power of the prototype system is as high as over 21 kWh for $50m^3$/h.

TiO2 광촉매 시스템을 이용한 음용수 중의 대장균 살균연구 (Disinfection of E.coli in Drinking Water by TiO2 Photocatalytic System)

  • 정진아;곽도환;오대웅;박동민;양오봉
    • Korean Chemical Engineering Research
    • /
    • 제50권1호
    • /
    • pp.11-17
    • /
    • 2012
  • 졸-겔 방법에 의하여 제조된 $TiO_2$$TiO_2-SiO_2$ 광촉매를 이용한 음용수 중의 대장균 살균과 엔도톡신 제거에 관한 연구를 수행하였다. 대장균 살균실험은 대장균이 포함된 물이 순환되는 annular-흐름식 광촉매 코팅 반응기에서 수행되었다. 대장균의 살균능은 $TiO_2$$TiO_2-SiO_2$ 광촉매의 아나타제 결정성피크의 세기와 비례하였다. UV-A 조사하에 $TiO_2$가 코팅된 반응기에서 2시간 내에 대장균을 100% 살균시킬 수 있었으며, 대장균 사멸시 생성되는 독성물질인 엔도톡신이 존재하지 않았다. 그러나 UV-C 조사하에서는 30분 이내에 대장균을 100% 살균할 수 있었으나 엔도톡신이 완전히 제게되지 않았다. 따라서 광촉매와 UV-A 조사가 음용수 살균에 유용함을 알 수 있었다.

유입수의 기계적 여과 후 자외선 살균에 의한 넙치 치어의 질병 저감 사례 연구 (Effect of UV disinfection following mechanical filtration for influent seawater on decrease in disease outbreak of juvenile olive flounder (Paralichthys olivaceus))

  • 강봉조;장영환;전봉근;박범희;신동혁
    • 한국어병학회지
    • /
    • 제28권3호
    • /
    • pp.125-131
    • /
    • 2015
  • 본 연구는 기계적 여과 후 자외선 살균처리한 양식장 유입수의 살균효율과 넙치 치어의 질병저감 효과를 평가하였다. 유입해수의 살균효율은 99.27%로 조사되었고, 기계적 여과 및 UV 살균처리 해수로 4개월 동안 사육한 넙치 치어는 대조구에 비하여 20~30%의 폐사율 저감효과가 관찰되었다.

Simulation Study for a UV Water Disinfection Unit Powered by a Photovoltaic System

  • Riahi, Said;Mami, Abdelkader;Minzu, Viorel
    • International Journal of Computer Science & Network Security
    • /
    • 제22권1호
    • /
    • pp.175-182
    • /
    • 2022
  • This work presents a simulation model for a specific UV disinfection system (UVDS) powered by a Photovoltaic System. The global UVDS also includes the electronic converters, Electronic Ballast, UV Lamp and Motor Pump. The equations that model the physical components' behaviour are connected to obtain a dynamic global model. The latter is converted in a Simulink/Matlab model, which allows to carry out simulation series concerning the entire UVDS. The physical parameters: the irradiation G and the temperature T, are considered as inputs. series of measurements carried out in order to show how these parameters affect the current, the voltage of the PVs and especially the value of the current of the UV lamp, on the other hand a study on the behavior and the evolution of the parameters of the motor pump such as the armature current, motor torque, speed of rotation and the water flow. The purpose of all this is to realize how important are the two parameters concerning the lamp current and the water flow because they are two very important factors to keep an adequate water quality.

하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동 (Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents)

  • 한지희;손진식
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

Impact of UV-C Irradiation on Bacterial Disinfection in a Drinking Water Purification System

  • Hyun-Joong Kim;Hee-Won Yoon;Min-A Lee;Young-Hoon Kim;Chang Joo Lee
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권1호
    • /
    • pp.106-113
    • /
    • 2023
  • The supply of microbiological risk-free water is essential to keep food safety and public hygiene. And removal, inactivation, and destruction of microorganisms in drinking water are key for ensuring safety in the food industry. Ultraviolet-C (UV-C) irradiation is an attractive method for efficient disinfection of water without generating toxicity and adversely affecting human health. In this study, the disinfection efficiencies of UV-C irradiation on Shigella flexneri (Gram negative) and Listeria monocytogenes (Gram positive) at various concentrations in drinking water were evaluated using a water purifier. Their morphological and physiological characteristics after UV-C irradiation were observed using fluorescence microscopy and flow cytometry combined with live/dead staining. UV-C irradiation (254 nm wavelength, irradiation dose: 40 mJ/cm2) at a water flow velocity of 3.4 L/min showed disinfection ability on both bacteria up to 108 CFU/4 L. And flow cytometric analysis showed different physiological shift between S. flexneri and L. monocytogenes after UV-C irradiation, but no significant shift of morphology in both bacteria. In addition, each bacterium revealed different characteristics with time-course observation after UV-C irradiation: L. monocytogenes dramatically changed its physiological feature and seemed to reach maximum damage at 4 h and then recovered, whereas S. flexneri seemed to gradually die over time. This study revealed that UV-C irradiation of water purifiers is effective in disinfecting microbial contaminants in drinking water and provides basic information on bacterial features/responses after UV-C irradiation.

Inactivation of various bacteriophages by different ultraviolet technologies: Development of a reliable virus indicator system for water reuse

  • Bae, Kyung Seon;Shin, Gwy-Am
    • Environmental Engineering Research
    • /
    • 제21권4호
    • /
    • pp.350-354
    • /
    • 2016
  • There is an urgent need to identify more reliable indicator systems for human pathogenic viruses in water reuse practice. In this study, we determined the response of different bacteriophages representing various bacteriophage groups to different ultraviolet (UV) technologies in real wastewater in order to identify more reliable bacteriophage indicator systems for UV disinfection in wastewater. Bacteriophage ${\varphi}X174$ PRD1, and MS2 in two different real wastewaters were irradiated with several doses of both low pressure (LP) and medium pressure (MP) UV irradiation through bench-scale UV collimated apparatus. The inactivation rate of ${\varphi}X174$ by both LP and MP UV was rapid and reached ${\sim}4{\log}_{10}$ within a UV dose of $20mJ/cm^2$. However, the inactivation rates of bacteriophage PRD1 and MS2 were much slower than the one for ${\varphi}X174$ and only ${\sim}1{\log}_{10}$ inactivation was achieved by the same UV dose of $20mJ/cm^2$. Overall, the results of this study suggest that bacteriophage MS2 could be a reliable indicator for human pathogenic viruses for both LP and MP UV disinfection in wastewater treatment processes and water reuse practice.

사여과수에 존재하는 우점세균의 중압 자외선 램프 소독능 (Disinfection Efficiency of Medium Pressure UV Lamp on Major Bacteria in Sand Filtered Water)

  • 안승구;양윤용
    • 대한환경공학회지
    • /
    • 제32권12호
    • /
    • pp.1141-1146
    • /
    • 2010
  • 상수공급계 모래여과수에 존재하는 종속영양 호기성 세균을 NA 및 TSBA 고체배지로 분리하고 군체의 형태 및 색체로 구분 정량하여 우점종 8종을 선정, 정제하고 Sherlock System으로 동정하였다. 이들 각 종류의 세균에 대하여 액체배양한 후 세정하여 $10^6{\sim}10^7\;cells/mL$ 증류수 현탁액을 조제하여 CBD 중압 자외선 램프로 0, 5, 16, 40, $60\;mJ/cm^2$ 조사량으로 조사한 후 희석, 평판배지에 접종 배양하여 생존 세균농도를 정량하여 불활성화율을 평가하였다. Gram 양성균으로 Bacillus subtillis, Bacillus megaterium, Rhodococcus erythropolis, Microbacterium laevaniformans 등이 Gram 음성균으로 Pseudomonas pseudoflava, Pseudomonas vesicularis, Alcaligenes paradoxus, Zooglea ramigera 등이 동정되었다. 분리된 세균종들은 중압 자외선 조사에 높은 저항성을 나타내었으며, 표준균주보다 강하였다. 또한 Gram 양성세균이 Gram 음성세균에 비해 월등히 강한 내성을 나타내었다. 중압 자외선 램프를 상수처리장의 소독목적으로 도입할 경우 $60{\sim}100\;mJ/cm^2$의 조사량으로 높여 조사하여야 할 것으로 판단된다.