• Title/Summary/Keyword: UT

Search Result 478, Processing Time 0.027 seconds

GPS TEC Fluctuations in the Low and High Latitudes During the 2015 St. Patrick's Day Storm

  • Chung, Jong-Kyun;Hong, Junseok;Yoo, Sung-Moon;Kim, Jeong-Han;Jee, Geonhwa;Hegai, Valery V.
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.245-250
    • /
    • 2017
  • As a part of collaborative efforts to understand ionospheric irregularities, the Korea ionospheric scintillation sites (KISS) network has been built based on global positioning system (GPS) receivers with sampling rates higher than 1 Hz. We produce the rate of TEC index (ROTI) to represent GPS TEC fluctuations related to ionospheric irregularities. In the KISS network, two ground-based GPS sites at Kiruna (marker: KIRN; geographic: $67.9^{\circ}$ N, $21.4^{\circ}$ E; geomagnetic: $65.2^{\circ}$ N) and Chuuk (marker: CHUK; geographic: $7.5^{\circ}$ N, $151.9^{\circ}$ E; geomagnetic: $0.4^{\circ}$ N) were selected to evaluate the ROTI value for ionospheric irregularities during the occurrence of the 2015 St. Patrick's Day storm. The KIRN ROTI values in the aurora region appear to be generally much higher than the CHUK ROTI values in the EIA region. The CHUK ROTI values increased to ~0.5 TECU/min around UT=13:00 (LT=23:00) on March 16 in the quiet geomagnetic condition. On March 17, 2015, CHUK ROTI values more than 1.0 TECU/min were measured between UT=9:00 and 12:00 (LT=19:00 and 22:00) during the first main phase of the St. Patrick's Day storm. This may be due to ionospheric irregularities by increased pre-reversal enhancement (PRE) after sunset during the geomagnetic storm. Post-midnight, the CHUK ROTI showed two peaks of ~0.5 TECU/min and ~0.3 TECU/min near UT=15:00 (LT=01:00) and UT=18:00 (LT=04:00) at the second main phase. The KIRN site showed significant peaks of ROTI around geomagnetic latitude=$63.3^{\circ}$ N and MLT=15:40 on the same day. These can be explained by enhanced ionospheric irregularities in the auroral oval at the maximum of AE index

Comparison of Muscle Activation on Cervical and Lumbar Erector Spinae, and Upper Trapezius according to Sitting Postures while using a Smartphone in a Bathroom (화장실에서의 스마트폰 사용 시 앉은 자세에 따른 목, 어깨, 허리의 근활성도에 미치는 영향)

  • Seo, Joon-Ho;Lee, Mi-Young;Kwon, Hyeok-Gyu
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.2
    • /
    • pp.71-77
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the level of muscle activation on the cervical erector spinae (CES), lumbar erector spinae (LES), and upper trapezius (UT) according to the sitting postures while using a smartphone in the bathroom. Method: Thirty-two healthy subjects were recruited for this study. The CES, LES, and UT were evaluated by surface electromyography according to two sitting postures while using a smartphone on the toilet seat. A paired t test was performed for the root mean square of reference voluntary contraction (%RVC) comparisons between two sitting postures, and one-way ANOVA was used to compare the three muscle activations within each posture. Results: A comparison between the two sitting postures revealed the muscle activation of both CESs in sitting posture 2 and both LESs in sitting posture 1 to be significantly higher than those of the others. In sitting posture 1, the muscle activation of both LESs was significantly higher than those of the CES and UT. In sitting posture 2, the muscle activation of both CESs was significantly higher than those of the LES and UT. Conclusion: High muscle activation of the CES and LES was observed according to the sitting postures when using smartphone in the restroom. Therefore, long time use of smartphones on a toilet seat should be avoided.

Comparison of the Serratus Anterior, Upper Trapezius, and Pectoralis Major Muscle Activity According to Horizontal Abduction and Horizontal Adduction Resistance and External Weight During Protraction Exercise (어깨뼈 내밈 운동 시 어깨관절 수평 벌림과 수평모음 저항과 외부 무게에 따른 앞톱니근, 위등세모근, 그리고 큰가슴근 근활성도 비교)

  • Bae, Chang-hwan;Kim, Kyu-ryeong;Cui, Zhe;Kim, Myoung-kwon;Park, Su-hyung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.37-46
    • /
    • 2021
  • Background: The increase in the activity of the upper trapezius (UT) muscle and decrease in the activity of the serratus anterior (SA) and lower trapezius (LT) muscle produce an abnormal scapulohumeral rhythem. Therefore, the SA is the focus of therapeutic exercise protocols for the rehabilitation. This study aimed to compare the activity of the muscles according to resistance levels during protraction exercise. Methods: Thirteen healthy 20 to 30 years old male and female subjected participated in the study. All subjects performed the scapular protraction exercise with the weights of 0, 5, and 10kg, combined with horizontal shoulder abduction and adduction. The electromyography data of the SA, UT, and pectoralis major (PM) during the exercise were recorded using surface electrodes. The ratios of PM/SA and UT/SA were calculated. Repeated one-way ANOVA was used to determine the statistical significance. Results: There was a significant difference in the muscle activity of the SA and PM (p<.05). Specifically, SA had the highest activity and PM had the lowest activity at an abduction resistance 10kg (p<.01). There was a significant difference in the ratios of UT/SA and PM/SA (p<.05). The ratio of PM/SA was the lowest at the abduction resistance of 10kg (p<.01). Conclusion: According to this study, for the selective activation of the serratus anterior, protraction exercises should be applied as a method of adding resistance to protraction and horizontal abduction.

Precise Orbit Determination Based on the Unscented Transform for Optical Observations

  • Hwang, Hyewon;Lee, Eunji;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.249-264
    • /
    • 2019
  • In this study, the precise orbit determination (POD) software is developed for optical observation. To improve the performance of the estimation algorithm, a nonlinear batch filter, based on the unscented transform (UT) that overcomes the disadvantages of the least-squares (LS) batch filter, is utilized. The LS and UT batch filter algorithms are verified through numerical simulation analysis using artificial optical measurements. We use the real optical observation data of a low Earth orbit (LEO) satellite, Cryosat-2, observed from optical wide-field patrol network (OWL-Net), to verify the performance of the POD software developed. The effects of light travel time, annual aberration, and diurnal aberration are considered as error models to correct OWL-Net data. As a result of POD, measurement residual and estimated state vector of the LS batch filter converge to the local minimum when the initial orbit error is large or the initial covariance matrix is smaller than the initial error level. However, UT batch filter converges to the global minimum, irrespective of the initial orbit error and the initial covariance matrix.

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

Development of Wall-Thinning Evaluation Procedure for Nuclear Power Plant Piping-Part 1: Quantification of Thickness Measurement Deviation

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.820-830
    • /
    • 2016
  • Pipe wall thinning by flow-accelerated corrosion and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall thinning that includes periodic measurements for pipe wall thicknesses using nondestructive evaluation techniques. Numerous measurements using ultrasonic tests (UTs; one of the nondestructive evaluation technologies) have been performed during scheduled outages in NPPs. Using the thickness measurement data, wall thinning rates of each component are determined conservatively according to several evaluation methods developed by the United States Electric Power Research Institute. However, little is known about the conservativeness or reliability of the evaluation methods because of a lack of understanding of the measurement error. In this study, quantitative models for UT thickness measurement deviations of nuclear pipes and fittings were developed as the first step for establishing an optimized thinning evaluation procedure considering measurement error. In order to understand the characteristics of UT thickness measurement errors of nuclear pipes and fittings, round robin test results, which were obtained by previous researchers under laboratory conditions, were analyzed. Then, based on a large dataset of actual plant data from four NPPs, a quantitative model for UT thickness measurement deviation is proposed for plant conditions.

Development of ISI UT Auto Flaw Evaluation and Acceptance Module of Nuclear Power Plants (원전 ISI UT 자동 결함평가 및 판정 모듈 개발)

  • Park, Ik-Keun;Park, Un-Su;Kim, Hyun-Mook;Kim, Chung-Seok;Um, Byong-Guk;Lee, Jong-Po
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.212-218
    • /
    • 2000
  • The importance and role of pre-/in-service inspection(PSI/ISI) for nuclear power plant(NPP) components are intimately related to plant design, safety, reliability, operation, etc. In this paper, for an effective and efficient management of large amounts of PSI/ISI data in NPPs, an intelligent database program(WS-IDPIN) for PSI/ISI data management of NPP was developed. WS-IDPIN program enables the prompt extraction of previously conducted PSI/ISI conditions and results so that the time-consuming data management, painstaking data processing and analysis in the past are avoided. Furthermore, development of ISI UT auto flaw evaluation and acceptance module based on ASME Code Sec. XI were presented. This module can be used for any angle beam examination from flat plate to spherical shapes as selected by the proper azimuthal angle. This program can be further developed as a unique PSI/ISI data management expert system.

  • PDF

A Feasibility Study for Flaw Detection in J-groove Weld of Reactor Upper Head Penetration Using Time of Flight Diffraction UT Technique (TOFD UT 기법을 활용한 원자로 상부헤드관통부 J-groove 용접부 결함 검출 가능성 평가)

  • Lee, Jeong Seok;Lee, Tae Hun;Kim, Yong Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.1-5
    • /
    • 2015
  • A failure or degradation of reactor upper head penetration is a troublesome problem at Nuclear Power Plants. A flaw in the reactor upper head penetration can result in unplanned plant shutdown for repair, and cause serious economic losses on the plants. Consequently, a detection of flaws is a matter of more importance. Until now, only the base metal, not including J-groove weld, in reactor upper head penetration has been inspected in accordance with 10 CFR 50.55a and ASME code case N-729-1 requirements. Accordingly, it is rather difficult to detect manufacturing defects and repair defects in J-groove weld. This paper presents a case study on the application of Time of Flight Diffraction UT technique to examine the J-groove weld in reactor head penetration using reactor head penetration mockup with artificial flaws. We expect that this study result will offer a way to understand the non-destructive examination technology for J-groove weld in reactor upper head penetration.

Consolidation Behavior of Soft Ground by prefabricated Vertical Drains (연직드레인 공법에 의한 연약지반의 압밀거동)

  • 이달원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.5
    • /
    • pp.133-143
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains was performed to anayze the effect of parameters of the very soft clay at a test site. compression index and the coefficient of horizontal consolidation obtained by back-analysis of settlement data were compared with those obtained by means of laboratory tests. Hyperbolic method, Asaoka meoth and curve fitting method were used to compute final settlement of coefficient of consolidation. The relationships of settlement measurement(Sm) versus design settlement(St) and the measurement consolidation ratio(Um) versus design consolidation (Ut) were shown as Sm=(1.0~1.1) St , Um=(1.13~1.17) Ut at 1.0m spacing of drain and Sm=(0.7~0.8)St, Um= (0.92~0.99) Ut at 1.5 m spacing of drain, respectively . The relationships of the field compression index(CcField) and virgin compression index(vcc lab) were shown as Ccfield =(1.0~1.2)vcc lab . But it was nearly within the same range when considering the error factor with the determination method of virgin compression index and the prediction back-analysis of the settlement data was larger than the coefficient of vertical consolidation, and the ratio of consolidation coefficient (Ch/Cv) was Ch =(2.4~2.9) Cv , Ch=(3.4~4.2) Cv at 1.0m and 1.5m spacing of drain, respectively.

  • PDF

A Study on the of influence to precision equipment by utility vibration of TFT-LCD fab (TFT-LCD 생산공장의 유틸리티 진동으로 인한 공장 구조물과 정밀장비로의 영향성)

  • Park, Hae-Dong;Im, Jung-Bin;Ryu, Kuk-Hyun;Baek, Jae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.886-892
    • /
    • 2006
  • 반도체 및 TFT-LCD등을 생산하는 공장 구조물에는 C/R이 있으며, 여기에는 외부 진동에 엄격한 특성을 갖고 있는 각종 수 많은 정밀장비가 설치되어 있다. 더구나, 이러한 정밀장비등의 정상운용을 위하여 각종 UT(유틸리티)등이 병행하여 C/R내 산재해 설치되어 있다. 이러한 UT는 정밀장비와 각종 배관들로 연결되어 설치되어 있다. 또한 C/R의 항온/항습등을 유지하기 위하여 공조등 부대 유틸리티도 또한 설치되어 있으며, 이러한 각종 유틸리티는 진동은 유발하는 진동원이 되며, 여기서 발생하는 진동은 C/R의 진동환경을 열악하게 만들 수 있다. 이에, 본 연구에서는 TFT-LCD 생산 공장에서 UT와 배관등에서 발생하는 진동이 공장 구조물(격자보)와 공진현상을 일으켜 인접하여 설치 된 정밀장비에 악영향을 끼치고 있음을 현장 진동 측정과 구조물 동적 해석을 통하여 확인하였고, 제안한 저감대책을 수행 후 진동 영향성의 감소됨을 확인하였다.

  • PDF