• 제목/요약/키워드: USP

검색결과 153건 처리시간 0.032초

Synthesis and Characterization of Al2O3/ZrO2, Al2O3/TiO2 and Al2O3/ZrO2/TiO2 Ceramic Composite Particles Prepared by Ultrasonic Spray Pyrolysis

  • Shim, In-Soo;Lee, Chang-Seop
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권8호
    • /
    • pp.1127-1134
    • /
    • 2002
  • Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutio ns of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle syntheses have been proposed.

아세트아미노펜 좌제의 용출과 직장흡수 (Dissoultion and Rectal Absorption of Acetaminophen from Suppositories)

  • 한정선;심창구;김신근
    • 약학회지
    • /
    • 제31권5호
    • /
    • pp.286-295
    • /
    • 1987
  • The relationship between in vitro release and in vivo bioavailability of acetaminophen from suppositories was investigated. Effect of glycyrrhizin on the drug release and rectal absorption in rats was also examined. Suppositories containing 25mg of acetaminophen were prepared with Wecobee FS (fatty base) or PEG (water-soluble base) bases. The release from the suppositories were determined with USP rotating basket dissolution apparatus and with the suppository release tester. The temperature of the dissolution medium was very critical for the dissolution of acetaminophen from Wecobee FS suppositories. The bioavailability of acetaminophen was calculated from the plasma concentration-time curve after rectal administration of the suppositories to the rats. There were no significant differences in AUC following rectal administration of Wecobee FS and PEG suppositories, but the release and absorption from the Wecobee FS suppositories were faster than those from PEG suppositories. The dissolution rate obtained by the suppository release tester was better correlated with in vivo absorption rate constant than that by the USP dissolution apparatus. It suggests that the partitioning between rectal fluid and suppository base is the rate-limiting step in the rectal absorption of acetaminophen from suppositories. Glycyrrhizin was found not to affect in vitro dissolution and rectal absorption of acetaminophen.

  • PDF

Development of a Food-Grade Integration Vector for Heterologous Gene Expression and Protein Secretion in Lactococcus lactis

  • Jeong, Do-Won;Lee, Jong-Hoon;Kim, Kyoung-Heon;Lee, Hyong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권11호
    • /
    • pp.1799-1808
    • /
    • 2006
  • A food-grade integration vector based on site-specific recombination was constructed. The 5.7-kb vector, pIMA20, contained an integrase gene and a phage attachment site originating from bacteriophage A2, with the ${\alpha}$-galactosidase gene from Lactobacillus plantarum KCTC 3104 as a selection marker. pIMA20 was also equipped with a controllable promoter of nisA ($P_{nisA}$) and a signal peptide-encoding sequence of usp45 ($SP_{usp45}$) for the production and secretion of foreign proteins. pIMA20 and its derivatives mediated site-specific integration into the attB-like site on the Lactococcus lactis NZ9800 chromosome. The vector-integrated recombinant lactococci were easily detected by the appearance of blue colonies on a medium containing $X-{\alpha}-gal$ and also by their ability to grow on a medium containing melibiose as the sole carbon source. Recombinant lactococci maintained these traits in the absence of selection pressure during 100 generations. The ${\alpha}-amylase$ gene from Bacillus licheniformis, lacking a signal peptide-encoding. sequence, was inserted downstream of $P_{nisA}\;and\;SP_{usp45}$ in pIMA20, and the plasmid was integrated into the L. lactis chromosome. ${\alpha}-Amylase$ was successfully produced and secreted by the recombinant L. lactis, controlled by the addition and concentration of nisin.

Efficacy of reciprocating instruments and final irrigant activation protocols on retreatment of mesiobuccal roots of maxillary molars: a micro-CT analysis

  • Lilian Tietz;Renan Diego Furlan;Ricardo Abreu da Rosa;Marco Antonio Hungaro Duarte;Murilo Priori Alcalde;Rodrigo Ricci Vivan;Theodoro Weissheimer;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.13.1-13.13
    • /
    • 2022
  • Objectives: This study evaluated the efficacy of 3 reciprocating systems and the effects of 2 instruments for irrigant activation on filling material removal. Materials and Methods: Forty mesiobuccal roots of maxillary molars were prepared up to size 25.06 and obturated. Micro-computed tomography (micro-CT) examination #1 was performed. Teeth were then divided into 4 groups (n = 10), according to the retreatment protocol: (1) manual, (2) Reciproc Blue, (3) WaveOne Gold, and (4) X1 Blue. Micro-CT examinations #2 and #3 were performed after filling removal and repreparation, respectively. Next, all teeth were divided into 2 new groups (n = 20) according to the irrigant activation protocol: XP Clean (XP Clean size 25.02) and Flatsonic (Flatsonic ultrasonic tip). Micro-CT examination #4 was performed after irrigant activation. Statistical analysis was performed with a significance level set at 5%. Results: WaveOne Gold removed a significantly greater amount of filling material than the manual group (p < 0.05). The time to reach the WL was similar for all reciprocating systems (p > 0.05). X1 Blue was faster than the manual group (p < 0.05). Only manual group improved the filling material removal after the repreparation stage (p < 0.05). Both activation protocols significantly improved the filling material removal (p < 0.05), without differences between them (p > 0.05). Conclusions: None of the tested instruments completely removed the filling material. X1 Blue size 25.06 reached the working length in the shortest time. XP Clean and Flatsonic improved the filling material removal.

기체 크로마토그래피를 이용한 $[^{18}F]$FDG 주사액 중의 잔류 용매의 정도관리 (Quality Control of Residual Solvents in $[^{18}F]$FDG Preparations by Gas Chromatography)

  • 이학정;정재민;이윤상;김형우;장영수;이동수;정준기;이명철
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권6호
    • /
    • pp.566-569
    • /
    • 2007
  • 목적: 의약품의 FDA 개정에 따라 $[^{18}F]$FDG에 휘발성 유기 용매의 분석을 GC로 수행하였다. $[^{18}F]$FDG 주사액은 약 3개월에 걸쳐 생산하면서 정도관리를 수행하였다. 대상 및 방법: $[^{18}F]$FDG 주사액에 존재하는 잔류유기용매의 종류를 줄이기 위해 $[^{18}F]$FDG자동합성장치를 ethanol을 이용해 세정하였다. $[^{18}F]$FDG주사액은 FID가 장착된 Hewlett-Packard 6890 Gas Chromatograph로 분석을 수행하였다. 생산된 $[^{18}F]$FDG의 시료는 상온에서 밀봉된 Vial에 보관하였고 일주일 내에 분석하였다. 결과: $[^{18}F]$FDG 생성물에서 ethanol의 양은 $16.8\sim2762.8ppm$이 검출 되었고 acetonitrile의 양은 $2.3\sim327.6ppm$이 검출 되었다. 결론: 약 3개월간 생산한 $[^{18}F]$FDG 주사액 중에 ethanol과 acetonitrile잔류 용매를 측정해본 결과 USP 허용기준인 ethanol 5000 ppm과 acetonitrile 400 ppm 이하가 유지됨을 확인하였다.

COINCIDENCE OF MAPS BETWEEN SURFACES

  • Goncalves, Daciberg L.
    • 대한수학회지
    • /
    • 제36권2호
    • /
    • pp.243-256
    • /
    • 1999
  • We will consider f,g : S1longrightarrowS2 a pair of maps between two orientable compact surfaces. The purpose of this paper is to decide when the pair can be deformed to a pair (f', g') such that

  • PDF

판크레아틴의 규격 표준화 연구 (Standardization of Pancreatin)

  • 신지은;윤혜경;김동현
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권4호
    • /
    • pp.273-279
    • /
    • 2003
  • Pancreatin is a enzyme mixture breaking down carbohydrates, proteins and lipids. Most pancreatin used in Korea is imported from foreign countries. However, guideline of each country for pancreatin produced from each country is different. Therefore, guideline for pancreatin imported from several countries, such as Europe, Japan and America, it is standardized to control its quality. Assay of enzyme activity for pancreatin in KP is similar to tat in JP, but it is significantly different from those in FP ad in USP. We measured pancreatin digestive activities of 17 commercial products. Activity assay of digestive enzymes, starch- and lipid-digestive enzymes, for pancreatin by KP method (including JP) was difficult compared to those by FIP ad USP methods. Particularly, activity assays of starch- and lipid-digestive enzymes by KP method were mistakable, ad varied in diluted samples than those by FIP. However, activity assay of protein-digestive enzyme by KP method was similar to that by FIP. Starch-digestive enzyme activities of 17 commercial pancreatins by KP method were lower 0.079-fold compared to those by FIP method. Their protein-digestive enzyme activities by KP method were higher 75.7-fold than those by FIP method. Their lipid-digestive enzyme activities by KP method were lower 0.234-fold compared to those by FIP method.