Implementation of BOOST Converter with Power Factor Correction(PFC) using a Single-phase On-line UPS (단상 On-line UPS를 이용하여 역율을 개선하는 BOOST 컨버터의 구현)

  • Han, Wan-Ok;Kim, Tae-Woong
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.47-52
    • /
    • 1999
  • This paper proposed simplified method to complicated Power Stage with a new On-line UPS scheme by replacing essential battery-voltage booster with a dual-functional PFC. Direct Load Voltage (${V_o}$) can not be applied to high voltage switching converter due to ripple from traditional Power Factor Correction (PFC) but Boost Function of On-line UPS is united so that the cost of system design and development is inexpensive. Through varification of experimental result, proposed UPS scheme shows its performance, low cost and high power density.

  • PDF

Design and Stability Analysis of a Fuzzy Adaptive SMC System for Three-Phase UPS Inverter

  • Naheem, Khawar;Choi, Young-Sik;Mwasilu, Francis;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.704-711
    • /
    • 2014
  • This paper proposes a combined fuzzy adaptive sliding-mode voltage controller (FASVC) for a three-phase UPS inverter. The proposed FASVC encapsulates two control terms: a fuzzy adaptive compensation control term, which solves the problem of parameter uncertainties, and a sliding-mode feedback control term, which stabilizes the error dynamics of the system. To extract precise load current information, the proposed method uses a conventional load current observer instead of current sensors. In addition, the stability of the proposed control scheme is fully guaranteed by using the Lyapunov stability theory. It is shown that the proposed FASVC can attain excellent voltage regulation features such as a fast dynamic response, low total harmonic distortion (THD), and a small steady-state error under sudden load disturbances, nonlinear loads, and unbalanced loads in the existence of the parameter uncertainties. Finally, experimental results are obtained from a prototype 1 kVA three-phase UPS inverter system via a TMS320F28335 DSP. A comparison of these results with those obtained from a conventional sliding-mode controller (SMC) confirms the superior transient and steady-state performances of the proposed control technique.

Design of High Stability Space Tube

  • Lee Deog-Gyu;Woo Sun-Hee;Lee Eung-Shik;Youn Heong-Sik;Paik Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.479-482
    • /
    • 2004
  • Laminate Design of a composite tube for a space telescope(Fig. 1) under hygrothermal load is studied. Carpet plots for laminate effective engineering constants are generated and used for selecting the best tube lay-ups satisfying the optomechanical requirements for a space telescope being dimensional1y stable under orbital thermal loading. Despace of the tubes constructed with the selected lay-ups are calculated with a Zig-Zag Triangular Element which accurately represents through thickness stress variations for laminated structures. The effects of moisture absorption when exposed to humidity environment and moisture desorption through outgassing on the dimensional stability are also investigated.

  • PDF

PWM Inverter Controller Design for UPS(Uninterruptible Power Supply) Using a DSP(TMS320F240) (DSP(TMS320F240)을 이용한 무정전 전원장치(UPS)용 PWM 인버터 제어기 설계)

  • Jang, J.Y.;Lee, J.P.;Choi, J.Y.;Choy, I.;Lee, S.C.;Yoo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2587-2589
    • /
    • 1999
  • In this paper, we propose a new control scheme for a PWM inverter using digital control. Digital control has various advantages in comparison with conventional analogue control. It can achieve high frequency switching of inverter and can be little influenced for temperature variations and aging of devices. This digitally-controlled PWM inverter is implemented using a Digital Signal Processor(DSPTMS320F240). The simulation results are given to verify the DSP based PWM inverter design and implementation.

  • PDF

Research on the optimization method for PGNAA system design based on Signal-to-Noise Ratio evaluation

  • Li, JiaTong;Jia, WenBao;Hei, DaQian;Yao, Zeen;Cheng, Can
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2221-2229
    • /
    • 2022
  • In this research, for improving the measurement performance of Prompt Gamma-ray Neutron Activation Analysis (PGNAA) set-up, a new optimization method for set-up design was proposed and investigated. At first, the calculation method for Signal-to-Noise Ratio (SNR) was proposed. Since the SNR could be calculated and quantified accurately, the SNR was chosen as the evaluation parameter in the new optimization method. For discussing the feasibility of the SNR optimization method, two kinds of PGNAA set-ups were designed in the MCNP code, based on the SNR optimization method and the previous signal optimization method, respectively. Meanwhile, the single element spectra analysis method was proposed, and the analysis effect of single element spectra as well as element sensitivity were used for comparing the measurement performance. Since the simulation results showed the better measurement performance of set-up designed by SNR optimization method, the experimental set-ups were built for the further testing, finally demonstrating the feasibility of the SNR optimization method for PGNAA setup design.

A study on single phase UPS inverter control with PDFF method (PDFF 제어기법을 이용한 단상 UPS 인버터 전압, 전류제어에 관한 연구)

  • Oh B. W.;Lee S. Y.;Lee Y. K.;Jeon Y. S.;Choe G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.799-802
    • /
    • 2004
  • There are many methods in controlling inverter's voltage and currents. most of all, PI control method is a general method. PI control has some merits. But, PI control has zero effect. So, steady-state response errors always exist by the zero effect. For removing the steady-state error, This paper presents the modeling, design and analysis of the double loop feedback control scheme. and computing the value of parameters and applying In the single-phase full bridge inverter for comparison and analysis between the PI control and PDFF control. The system model is employed to examine the dynamics of power circuit and select appropriate feedback variables for stable operation of the closed-loop UPS inverter system. It analyzes and proves the output characteristic of inverter system with the PDFF control.

  • PDF

Comparison of Current Control Method for Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 전류 제어기법 비교)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • This paper describes the performance comparison results for current controller of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS(Uninterruptible Power Supply). A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of current controller design and comparison of current control method has not been known after the converter circuit was proposed. For the performance comparison of current control, single-phase 3 kVA double-conversion UPS was tested. The performance of PI and PR current controller is experimentally confirmed with followings - input current reference tracking, input power factor correction and input current THD suppression.

A Study on the Effect of Follow-Up on Mail Survey for Park Users (공원이용자 연구시, Follow-Up 기법이 우송조사법에 미치는 경향에 관한 연구)

  • 홍성권
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.21 no.4
    • /
    • pp.29-41
    • /
    • 1994
  • The purposes of this study are (a)to investigate the effect of follow-up on the increase of response rate;(b)to analyze the effect of follow-up on the statistics by predetermined response rates ; therefore, (c)to describe the importance of high response rate and to suggest methods in order to increase response rate in mail survey. Telephone directory of Seoul was utilized as a sampling frame, and modified Total Design Method(TDM) was applied to collect the data. The results are summarized as follows. 1. Final response rate was 76.5% by 2 follow-ups. 2. The first follow-up with telephone call had a significant effect on increase of response rate. As a result, follow-up by postcard in TDM could be omitted in this method. 3. The second follow-up by registered mail did not have a significant effect. Therefore, use of this procedure is depending upon such research situtations as importance of high response rate and cost available. 4. Follow-ups helped to make collected sample highly representative. 5. Most questionnaires were arrived on the first half of data collection period in each follow-up. 6. Most of questionnaires were collected for 10 weeks. Accumulated responses could be fitted by exponential and logistic curve, simultaneously. The fitted curve suggested that eventually limited number of questionnaires by arrived. So, if researchers want higher response rate, they have to conduct more follow-ups. 7. Statistics in the predetermined response rate were not changed significantly. But replications are needed to generalize this result.

  • PDF

Design and Control Method for Critical Load Supply Equipment using MCFC Electricity Generation Systems (대용량 MCFC 발전시스템을 이용한 비상부하 전력 공급 장치 설계 및 제어방법)

  • Kim, Dong-Hee;Kim, Jong-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Kawk, Cheol-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.20-29
    • /
    • 2011
  • This paper proposes critical load following back-up system using MCFC stack. This system enables MCFC generation system to supply power to critical load without UPS and to generate rated power under grid fault state. This back-up system includes 'Load Leveler' that is connected with 3-phase inverter and is controlled by additional algorithm that includes critical load following. The proposed system and algorithm are verified by computer simulation based on 5kW system.