• Title/Summary/Keyword: UPS design

Search Result 211, Processing Time 0.029 seconds

Design of Input.Output Filter of Single Multifunctional UPS (단상 다기능 UPS 입.출력 필터 설계)

  • 김제홍
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Design and Implementation UPS Management System in HFC Network (HFC 전송망을 이용한 UPS 원격관리 시스템의 설계와 구현)

  • 김영화;강준우
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.75-78
    • /
    • 2002
  • Since power failures in high-speed communication network, especially in HFC(Hybrid Fiber Coaxial cable) network are critical, microcontroller-based UPS(Uninterrupted Power Supply) are commonly used in the network. Hardware and software of UPS management system is designed and implemented to monitor and control UPS status to supply electric power to ONU and TBA in the HFC network. The result of laboratory tests and field tess of this system shows the scan rate to be 1 to 10 minutes to sufficiently monitor the status of UPS in the network.

  • PDF

The Configurations of the large scale UPS system (대규모 무정전 전원공급 시스템의 구성방안)

  • 송언빈;윤병도
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.80-83
    • /
    • 1991
  • The need of UPS (Uninterruptible Power Sup-ply) system is dramatically increasing with the increased use of computers, telecommunica-tion system, building automation system, and office automation system in office buildings. The consequence of the power failure is very disas trous in intelligent office buil-dings. Thus, the nucessity of large scale UPS system with generations of large scale UPS system with generator is increasing. In this study, the configurations of large scale UPS system are reviewed and analyzed. The design guide and technical considerations of high reliability system are presented.

  • PDF

The Construction of the UPS system for supercomputer system (슈퍼컴퓨터 시스템을 위한 무정전 전원공급 시스템의 구축)

  • Sung, Jin-Woo;Woo, Joon;Kim, Sung-Jun;Choi, Yun-Keon;Hong, Tae-Yeong;Lee, Young-Joo;Jang, Ji-Hoon;Lee, Sang-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.462-465
    • /
    • 2009
  • This study described the design and construction of uninterruptible power supply(UPS) system for supercomputering system. KISTI's supercomputer system is served for all 24 hours, and power be achieved in stable voltage and frequency range. We analyzed the electric power usage for 4 years, and we considered cost and stability and we contructed UPS for supercomputer system.

  • PDF

Design of Input Output Filter of Uninterruptible Power Supply (무정전전원장치(UPS)의 입출력필터설계에 관한 연구)

  • Kim, Je-Hong;Cho, Yang-Heang;Son, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.132-135
    • /
    • 2005
  • A design for the input filter and the output filter of a single-phase uninterruptible power supply (UPS) system is proposed. A filter design example is presented. And also, this dissertation describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Design of off-line UPS with AVR (AVR 기능 부가 off-line UPS 설계)

  • Lee, Seung-Hee;Park, Tae-Jun;Lee, Jin-Hee;Lee, Wang-Ha;Lee, Chi-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.605-607
    • /
    • 2001
  • In this paper, an off-tine UPS with CVT(constant voltage transformer) is designed and the experimental result and problems of the designed UPS is given and discussed. This off-line UPS consists of triple-port CVT and PWM inverter which acts as charger and inverter. It can be evaluated in low price because haying simple structure. It offers high performance because CVT restricts the short current automatically about two or three times of rated current, has nearly unit power factor and constant output voltage to varying input voltage. The weak points of this UPS are that the output voltage waveform is not perfect sinusoidal and has phase difference to input voltage. The experimental result and problems of the designed UPS is given.

  • PDF

Analysis of Output Characteristics and Design of LC Filter for Line-Interactive 3-Phase APF (3상 라인인터액티브형 능동전력필터 시스템을 위한 LC필터 출력특성 해석 및 설계)

  • 김응진
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.127-132
    • /
    • 2000
  • This paper describes a 3-phase Line-Interactive APF system and analyzes its operating characteristics considering LC Filter output characteristics. Topology of APF is similar to that of Off-Line UPS in the point of parallelly operating inverter system. So it is possible to be multi-functioned active compensating system according to power condition. Likewise this actively operating system from APF to UPS and vice versa is often to be called Line-Interactive system. And more than that Line-Interactive system needs precise design of LC filter on converter output side to make this system fully operate in both APF and UPS modes. The problem in this point is how to design LC Filter to be contented with two different system characteristics so this paper analyzes this problem and proposes its design procedures. Then suggested filter design is verified to be contented by the simulations and experimental results

  • PDF

The Development of Uninterruptible Power Supply for Power Pla (발전소용 무정전전원장치 (UPS)개발)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2085-2087
    • /
    • 1997
  • The UPS for power plant is mainly used as the critical power supply of power plant. This is very much alike to the general UPS but it requires the special design criteria of power plant. In this study, we designed and develope system according to the design criteria of p plant. In the development of the special system, the designs of IGBT Drive, heat protection and monitoring system, and p components are key techniques. This Paper describes the power circuits, key techniques, the control and monitoring of the developed UPS(DC 125V $3{\Phi}$ 100K Finally, using the UPS we verified superiority through the type test.

  • PDF

Design of UPS system using SMB Flywheel Energy Storage System (초전도 플라이휠 에너지 저장시스템을 이용한 UPS 설계)

  • 정환명;최재호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.610-619
    • /
    • 2000
  • This paper presents an off-line UPS using the high temperature superconductive magnetic bearing. FES(Flywheel Energy Storage) system has good advantages in compare with lead acid battery. So, high efficiency FES using high temperature SMB(superconductive magnetic bearing) was composed in this paper. The outer rotor type of PMSM(Permanent Magnet Synchronous Motor) as motor/generator was used for the experiment, and square wave current and sinusoidal wave control methods was compared for high efficiency operation of motor/generator. The circuit for in phase sinusoidal wave current control with EMF in the full speed range was designed and the proposed flywheel energy storage system was applied in single phase off-line UPS system. As the stable operation characteristics of prototype system was confirmed, the its excellence as energy storage device in Off-line UPS was proved.

  • PDF

A Modular UPS Design with an Active Multiple Interphase Reactor and Double PLL Control (능동 다중인터페이스 리액터와 Double PLL제어를 이용한 Modular UPS 설계)

  • 박인덕;정상식;안형회;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.489-497
    • /
    • 2001
  • The proposed dobule phase locked loop and active multiple interphase reactor are used to eliminate the circular current and the voltage ripples caused by the system parameter unbalance of parallel connected UPSs. In this paper, digital controller for the dobule PLL and active interphase reactor is implemented with ADSP21061 as an aspect of functional convenience.

  • PDF