• 제목/요약/키워드: UL 1699

검색결과 37건 처리시간 0.028초

이산 웨이블렛 변환을 이용한 직렬 아크고장 신호 검출 방법 분석 (Analysis of Detection Method for Series Arc Fault Signal by using DWT)

  • 방선배;김종민;박종연;정영식
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.362-368
    • /
    • 2009
  • Electrical fires have been occurred continuously in spite of installing ELB. Therefore the concern with the electrical arc-fault that cause the fire has growing. This paper measured series arc fault currents by the method of arc generator test in UL standard 1699. The used analysis methods in this paper are three different ways using DWT(discrete wavelet transform) those are frequently used for the arc fault current signal analysis. The arc fault detection probability is 100 % by method using noise-energy/shoulder-duration ratio of approximation coefficient. As these results, the variation of noise-energy and shoulder-duration ratio of approximation coefficient are founded important factors for the analysis of arc fault.

아크발생에 따른 태양광 인버터의 효율 특성 연구 (The Study Efficiency Characteristics of PV Inverter by Series Arc)

  • 김승열;서현욱;권완성;이영진;한동화;반충환;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.159-160
    • /
    • 2012
  • For renewable energy has been studied by many research. among them, non-pollution and infinite solar energy using solar power system is newly spotlighed. the DC output characteristic of the solar cell, connection to grid and using the inverter is essential to the process of converter DC to AC. in this paper, study the corresponding changes in the efficiency of the inverter and arcing occurs in the inverter, depending on the conditions and regulations in the UL-1699 series arc occurs.

  • PDF

직렬아크 방전의 주파수 스펙스럼 분석

  • 김선재;정광석;박대원;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.24-24
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of electromagnetic waves which is generated by series arc discharges to develop a condition monitoring technique in a closed-distribution board. We fabricated an arc generator specified in UL1699 to simulate series arc discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of a Ultra Log Antenna and a EMI Test Receiver. The results showed that the frequency spectrum during series arc discharges was distributed in ranges of 30~500 [MHz], and the peak values were existed at 40 [Mhz] and 80 [MHz].

  • PDF

이산 웨이블렛 변환을 이용한 직렬 아크고장전류 분석 (Analysis of Series Arc Fault Current Using Discrete Wavelet Transform)

  • 방선배;김종민;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.318-321
    • /
    • 2009
  • 누전차단기 설치 상태에서도 전기화재가 지속적으로 발생함에 따라 전기화재의 원인이 되는 전기 아크에 대한 관심이 증가하고 있는 실정으로 본 논문에서는 UL1699의 아크 저해시험(inhibition tests)에서 제시하고 있는 직렬 아크코장시험(Arc generator test)을 실시하고, 아크고장전류 분석방법으로 최근에 많이 사용되고 있는 이산 웨이블렛 변환을 이용한 3가지 분석방법에 대하여 아크고장전류 검출 확률을 분석하였다. 분석결과, (1) 근사계수 분석에 의한 최대치 변화율 실효치 변화율 분석방법은 46%의 검출 확률을 얻을 수 있었고, (2) 상세계수 분석에 의한 최대치 변화율 실효치 변화율 분석방법은 62%, (3) 근사계수 분석에 의한 잡음량 변화율 shoulder 변화율 분석방법은 100% 검출 확률을 얻을 수 있었다.

  • PDF

방사전자파의 주파수분석에 의한 배전반 진단기술 (Diagnostic Technique of a Switchboard by Frequency Analysis of Radiated Electromagnetic Wave)

  • 박대원;김선재;정광석;길경석;조은제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves generated by series arc- and corona- discharges as a basic study to develop an online diagnostic technique for power facilities installed inside switchboards. To simulate corona and series arc discharges, an arc generator specified in UL1699 and a corona generator were fabricated. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. The frequency spectrum exists in ranges from 30 to 500 [MHz] for series arc discharge and 30 [MHz] to 2 [GHz] depending on defects for corona discharge. The peak frequency of series arc discharge and corona were 40 [MHz], 80 [MHz] and 35 [MHz]~160 [MHz], respectively.

  • PDF

에어컨에서 직렬아크검출 알고리즘에 관한 연구 (A Study on the Detection Algorithm of Series Arc Signals in Air Conditioners)

  • 지홍근;최성국;정광석;박대원;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1970-1976
    • /
    • 2009
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 170 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF

저압계통에서 직렬아크신호의 검출 (Detection of Series Arc Signal in Low-voltage Systems)

  • 지홍근;박찬용;길경석;김일권;조영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.316-320
    • /
    • 2008
  • This paper described the design and fabrication of a series arc detection module to monitor electrical insulation in low-voltage system. The module consists of a passive high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a frequency of 4 kHz to detect series arc signals only. For the application experiment, we simulated series arcing phenomena on various loads such as incandescent lamp controlled by dimmer and inverter fed induction motors by an arc generator specified in UL1699. From the experimental results, we could detect series arc signals without an influence of noises.

  • PDF

선형부하의 직렬아크검출을 위한 주파수영역 분석 (Frequency Domain Analysis of the Linear Load for Series Arc Detection)

  • 강경필;방선배;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.524-525
    • /
    • 2014
  • In this paper, we propose algorithm plan variable for detection of DC arc. Changes of surrounding frequencies of harmonic wave is proposed to detect DC arc. To prove validity of these variables, we analyzed frequency based on the measured data and waveform of load current by performing the experiment which generates DC arc by using DC arc generator regulated in UL1699 was carried out.

  • PDF

교류부하에서 발생되는 직렬 아크의 신속한 검출 방법에 관한 연구 (A Study on Fast Detecting Technique of Series Arc in the AC Load)

  • 김승열;권완성;변병주;임종웅;방선배;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.580-581
    • /
    • 2012
  • 아크는 전기화재의 주요 원인 중 하나이며 전기 배선이나 설비 등에서 두 전극 사이의 기체를 통하여 방전되면서 빛과 열을 발산하는 현상이다. 본 논문에서는 UL-1699에서 규정하고 있는 직렬아크의 발생 조건에 따라 모의 아크 발생장치를 통하여 여러 가정용 부하에서 아크를 발생시키고 주파수 영역에서의 아크전류파형을 분석해 보고 신속한 아크 검출 방법을 연구하고자 한다.

  • PDF

직렬아크신호의 검출 (Detection of Series Arc Signal)

  • 지홍근;박대원;김일권;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.225-229
    • /
    • 2008
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 3 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF