• Title/Summary/Keyword: UCLA

Search Result 347, Processing Time 0.033 seconds

Current Status of Immunotherapeutic Strategies for Central Nervous System Tumors

  • Yang, Meng-Yin;Khan-Farooqi, Haumith;Prins, Robert M.;Liau, Linda M.
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.217-226
    • /
    • 2006
  • Malignant gliomas are the most common type of primary brain tumor and are in great need of novel therapeutic approaches. Advances in treatment have been very modest, significant improvement in survival has been lacking for many decades, and prognosis remains dismal. Despite "gross total" surgical resections and currently available radio-chemotherapy, malignant gliomas inevitably recur due to reservoirs of notoriously invasive tumor cells that infiltrate adjacent and non-adjacent areas of normal brain parenchyma. In principle, the immune system is uniquely qualified to recognize and target these infiltrative pockets of tumors cells, which have generally eluded conventional treatment approaches, In the span of the last 10 years, our understanding of the cancer-immune system relationship has increased exponentially; and yet we are only beginning to tease apart the intricacies of the central nervous system and immune cell interactions. This article reviews the complex associations of the immune system with brain tumors. We provide an overview of currently available treatment options for malignant gliomas, existing gaps in our knowledge of brain tumor immunology, and strategies that might be exploited for improved design of "custom immunotherapeutics." We will also examine major new immunotherapy approaches that are being actively investigated to treat patients with malignant glioma, and identify some current and future research priorities in this area.

Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer (합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향)

  • Lee, Yun-Hui;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • Purpose: The object of this study was to determine if the low-priced alloy and metal UCLA abutment could be available for manufacturing bar-retained framework of implant prosthesis. Materials and methods: Bar structure was classified into 4 groups, The specimen of group 1 and 2 were based on casting high noble metal alloys and noble metal alloys with gold UCLA abutment. The specimen of group 3 and 4 were based on casting noble metal alloys and base metal alloys with metal UCLA abutment. Cast bar structure was installed in an acrylic resin model and only the screw on the hexed abutment side was tightened to 20 Ncm. On the opposite side, vertical discrepancy was measured with stereo microscope from front, back, and lateral side of the implant-abutment interface. One-way ANOVA was performed to analyze the marginal fit discrepancy. Results: One-way ANOVA test showed significant differences among all groups ($P$<.05) except for Group 1 and 3. Among them, difference between Group 1 and 2 was noticeable. Measured vertical discrepancies were all below $70{\mu}m$ except to Group 2. Conclusion: Base metal alloy and metal UCLA abutment could be used as an alternative to high-priced gold alloy for implant bar-retained framework.

EFFECT OF CASTING PROCEDURE ON SCREW LOOSENING OF UCLA ABUTMENT IN TWO IMPLANT-ABUTMENT CONNECTION SYSTEMS

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.246-254
    • /
    • 2008
  • STATEMENT OF PROBLEM: The cast abutment has advantages of overcoming angulation problem and esthetic problem. However, when a gold-machined UCLA abutment undergoes casting, the abutment surfaces in contact with the implant may change. PURPOSE: The purpose of this study was to compare the detorque values of prefabricated machined abutments with gold-premachined cast-on UCLA abutments before and after casting in two types of internal implant-abutment connection systems: (1) internal hexagonal joint, (2) internal octagonal joint. Furthermore, the detorque values of two implant-abutment connection systems were compared. MATERIALS AND METHODS: Twenty internal hexagonal implants with an 11-degree taper and twenty internal octagonal implants with an 8-degree taper were acquired. Ten prefabricated titanium abutments and ten gold-premachined UCLA abutments were used for each systems. Each abutment was torqued to 30 N㎝ according to the manufacturer's instructions and detorque value was recorded. The detorque values were measured once more, after casting with gold alloy for UCLA abutment, and preparation for titanium abutments. Group means were calculated and compared using independent t-test and paired t-test (${\alpha}$=0.05). RESULTS: The results were as follows: 1. The detorque values between titanium abutments and UCLA-type abutments showed significant differences in internal octagonal implants (P<0.05), not in internal hexagonal implants (P>0.05). 2. In comparison of internal hexagonal and octagonal implants, the detorque values of titanium abutments had significant differences between two connection systems on the initial analysis (P<0.05), not on the second analysis (P>0.05) and the detorque values of UCLA-type abutments were not significantly different between two connection systems (P>0.05). 3. The detorque values of titanium abutments and UCLA-type abutments decreased significantly on the second analysis than the initial analysis in internal hexagonal implants (P<0.05), not in internal octagonal implants (P>0.05). CONCLUSION: Casting procedures of UCLA-type abutments had no significant effect on screw loosening in internal implant-abutment connection systems, and UCLA-type abutments showed higher detorque values than titanium abutments in internal octagonal implants.

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

  • Yoon, Ki-Joon;Park, Young-Bum;Choi, Hyunmin;Cho, Youngsung;Lee, Jae-Hoon;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.465-471
    • /
    • 2016
  • PURPOSE. The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of $1.0{\times}10^6$cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

Multiple shRNA expressing vector enhances efficiency of gene silencing

  • Song, Jun;Giang, An;Lu, Yingchun;Pang, Shen;Chiu, Robert
    • BMB Reports
    • /
    • v.41 no.5
    • /
    • pp.358-362
    • /
    • 2008
  • RNA interference (RNAi) is the process of sequence-specific gene silencing. However, RNAi efficiency still needs to be improved for effective inhibition of target genes. We have developed an effective strategy to express multiple shRNAs (small hairpin RNA) simultaneously using multiple RNA Polymerase III (Pol III) promoters in a single vector. Our data demonstrate that multiple shRNAs expressed from Pol III promoters have a synergistic effect in repressing the target gene. Silencing of endogenous cyclophilin A (CypA) or key HIV viral genes by multiple shRNAs results in significant inhibition of the target gene.

Korean Version of the Revised UCLA Loneliness Scale : Reliability and Validity Test (한국어로 번역된 UCLA 외로움 사정도구의 신뢰도 및 타당도 조사)

  • Kim Ok Soo;Rn., Ph.D.
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.871-879
    • /
    • 1997
  • 인간은 사회적 접촉을 필요로 하고 타인과의 상호작용을 원하는 사회적 동물이다. 외로움은 한 개인의 사회적 관계의 망이 양적이나 질적으로 부족할 때 발생하는 불유쾌한 감정이다. 외로움은 매우 보편적인 감정이나 고통스러울 수 있으며 이러한 경험이 지속되면 정신적, 신체적 건강을 해칠 수 있을 뿐 아니라 자살을 초래하기도 한다. 특히 노인은 여러 가지 종류의 변화와 상실을 경험하기 때문에 외로움을 더 느낄 수 있다. 본 연구의 목적은 번역과 역번역 과정을 통해 Revised UCLA Loneliness Scale에 대한 한국어 UCLA 외로움 사정도구를 만들고 이 도구를 한국노인에게 적용하여 신뢰도와 타당도를 조사하는 것이다. 개정판UCLA외로움 사정 도구는 각각 3번씩의 번역과 역번역 과정을 통해 원본 영문도구와 역번역된 영문도구 사이에 의미의 차이가 없다고 판단될 때까지 만들어졌다. 번역과 역번역 과정은 미국에서 석사나 박사학위를 취득한 6명의 한국유학생들에 의해 이루어 졌으며 원본 영문도구와 역번역된 도구사이의 의미의 차이는 본 저자와 미국인 간호학 교수에 의해 사정되었다. 번역된 한국어 외로움 사정도구는 미국의 3개 주에 거주하는 203명의 한국노인들을 대상으로 신뢰도와 타당도 조사가 이루어졌다. 한국어 UCLA외로움 사정도구의 신뢰계수는 .93으로 한국어 도구의 내용이 전반적으로 동질성을 띈다는 것을 알 수 있었다. 이는 Barren등(1992)이 미국인 노인여성을 대상으로 한 연구에서 얻은 신뢰계수 .87보다 높은 것이었다. 한국어 도구의 구성타당도를 조사하기 위해 요인 분석을 실시한 결과 본 도구는 친밀한 주변인, 사회적 주변인, 및 소속감 등의 3개 요인을 가지는 것으로 분석되었다. 구성타당도에 대한 이러한 결과는 미국의 대학생들을 대상으로 한 Austin(1983)의 연구결과와 일치하는 것이었다. 각 요인에 대한 신뢰계수는 .88(제 1요인), .90(제 2요인), .84(제 3요인)로 나타났다. 전반적으로 대상자들은 한국어 도구에 대해 이해를 잘 하는 편이었으나 부정문인 4번 항목, '나는 혼자라고 느끼지 않는다'에 대해서는 응답을 할 때는 다른 항목에 비해 시간이 더 소요되거나 연구보조자에 의한 반복 설명이 필요하기도 하였다.

  • PDF

Interest in Health Promotion Among Korean American Seventh-day Adventists Attending a Religious Retreat

  • Jo, Angela M.;Maxwell, Annette E.;Choi, Sun-Hye;Bastani, Roshan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2923-2930
    • /
    • 2012
  • Background: Little is known about interest in faith-based health promotion programs among Asian American populations. Among the Christian denominations, the Seventh-day Adventist (SDA) church is known to place a strong doctrinal emphasis on health. Objectives: To understand appropriate ways to develop and implement health promotion programs and to conduct research among Korean American SDAs. Methods: We collaborated with the North American Division of Korean SDA Churches which sponsors annual week-long religious retreats for their church members. We developed and administered a 10-page questionnaire at their 2009 retreat in order to assess socio-demographic and church characteristics, religiosity, perceived relationship between health and religion, and interest and preferences for church-based health promotion programs. Results: Overall, 223 participants completed our survey (123 in Korean and 100 in English). The sample consisted of regular churchgoers who were involved in a variety of helping activities, and many holding leadership positions in their home churches. The vast majority was interested in receiving health information at church (80%) in the form of seminars, cooking classes and workshops (50-60%). Fewer respondents were interested in support groups (27%). Some interests and preferences differed between English and Korean language groups. Conclusion: Korean American SDA church retreat participants from a large geographic area are very interested in receiving health information and promoting health at their churches and can potentially serve as "agents of influence" in their respective communities.