• 제목/요약/키워드: U. V. Laser

검색결과 45건 처리시간 0.025초

비정질 칼코게나이드에서 광유기 스칼라 현상의 가역성에 관한 연구 (A Study on the Reversibility Scalar Phenomena in Amorphous Chalcogenides)

  • 박수호;정진만;이현용;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.31-34
    • /
    • 1997
  • A reversible scalar phenomena in amorphous As$_{40}$ Ge$_{10}$ Se$_{15}$ S$_{35}$ have been investigated by blue-pass-filtered Hg lamp and He-Ne laser. Annealing causes the shift of the absorption edge to shelter wavelengths approximately 0.17ev, also illumination moves it to longer wavelengths about 0.05 ~ 0.07eV and it increases the refractive index maximum 0.3. Therefore the thermalbleaching(TB) and photodarkening(PD) effects have been understood by the results related to optical absorption characteristics. TB could be estimated as increasing the stabilization of amorphous chalcogenide films since absorption slope of extended regions(U) was not changed by annealing. On the other hand, PD could be understood as due to the enhancement of disorder since the slope of Urbach’s tail(1/F) around an absorption edge were decreased by illumination.ion.n.

  • PDF

A Backlight Feedback Control System with Integrated Color Sensor on LCD

  • Lee, Ki-Chan;Park, Yun-Jae;Ko, Hyun-Seok;Moon, Seung-Hwan;Park, Jin-Hyeok;Berkeley, Brian;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1550-1551
    • /
    • 2005
  • In this paper, to improve the well-known photo conductivity degradation of amorphous silicon, a new LASER immersion treatment has been applied. The optical feedback control LED backlighting system with integrated LCD panel sensor increased the color variation less than 0.008 ${\Delta}u'v'$ compared to 0.025 for a non-feedback system.

  • PDF

탄산가스 레이저 조사가 노출 치수에 미치는 영향에 관한 연구 (AN HISTOPATHOLOGICAL STUDY ON THE EFFECT OF $CO_2$ LASER IRRADIATION ON THE EXPOSED DENTAL PULP)

  • 김종규;이긍호
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.27-40
    • /
    • 1997
  • This study investigated the effects of laser irradiation on the exposed pulp and the possibility of direct pulp capping with the $CO_2$ laser. Results were obtained from the observation of the residual pulpal healing process. Class V cavities on 48 anterior teeth from 8 adult dogs were prepared and pulp chambers were intentionally opened with dental explorer. The control group consisted of 16 teeth. $Dycal^{(R)}$(Caulk Co., U.S.A.) was applied to exposed site once bleeding was stopped. Cavities were sealed with $I.R.M^{(R)}$. In the experimental group 1 (16 teeth), laser(LASERSAT $CO_2^{(R)}$, Satelec Co.) was irradiated on the exposed pulp. The laser procedure followed the manufacturers recommendations for the treatment of human pulp(1.5 Watts, 0.2 seconds, unfocused), and cavities were sealed with $I.R.M^{(R)}$. In the experimental group 2 (16 teeth), laser was irradiated on the exposed pulp in a more powerful dosage(5.0 Watts, 0.2 seconds, unfocused), and cavities were sealed with $I.R.M^{(R)}$. Two dogs were sacrificed immediately after experiment and the others were sacrificed at intervals of one, three, and eight weeks respectively. All teeth were routinely processed and the pulpal tissues and odontoblastic layers were observed by the light microscope. The results were as follows; 1. In the control group, the initial mild inflammation had improved to normal by week eight. An active formation of reparative dentin was observed at week three, and at week eight, a firm dentin bridge was present beneath the $Dycal^{(R)}$ with no inflammatory responses in the remaining pulp. 2. In the experimental group 1, immediately following irradiation, the superficial shape of the exposed pulp was crater-like. And it was lined with the coagulated layer, $60{\sim}70{\mu}m$ in width. Moderate inflammatory pulpal conditions existing at week one were improved to mild at week eight. And from the week three specimens, a reparative dentin formation was observed in the adjacent odontoblastic layer of the exposed site. A dentin bridge at the exposed site, however, did not form during the experimental period. 3. In the experimental group 2, the width of the coagulation layer lining the crater was $70{\sim}130{\mu}m$. Beneath the coagulated layer, severe inflammatory pulpal responses were observed at week one, and conditions did not improve during the experimental period.

  • PDF

자외선 레이저를 이용한 고정밀 저항체 가공기술 개발 (Development of Trimming Technology in High-fine Resistor Using U.V. Laser)

  • 노상수;김동현;정귀상;김형표;김광호
    • 센서학회지
    • /
    • 제11권6호
    • /
    • pp.358-364
    • /
    • 2002
  • 본 논문에서는 백금박막 온도센서의 $0^{\circ}C$, $100{\Omega}$ 세팅을 위해 355nm 파장을 갖는 자외선 레이저를 이용하였다. 국제적으로 온도센서의 A-class 기준오차는 $0^{\circ}C$에서 ${\pm}0.060{\Omega}$이다. 실제적으로 이 값은 $0.15^{\circ}C$이하에 해당하는 오차로 저항체 제작시 고정밀 가공 기술을 필요로 한다. 가공에 이용된 355nm DYP(Diode-Pumped YAG) 레이저는 power : 37mW, rep rate 주파수 : 200Hz 그리고 bite size : $7.5{\mu}m$에서 $1{\sim}1.5{\mu}m$ 두께의 백금박막을 가장 안전하게 가공할 수 있었으며, 가공선폭은 $10{\mu}m$ 안팎임을 확인하였다. 그리고 사진식각 공정기술을 이용하여 제작된 $2"{\times}2"$ 기판내의 96개(4 by 24) 저항체는 상온 $25^{\circ}C$에서 $79{\sim}90{\Omega}$ : 42.7%, $91{\sim}102{\Omega}$ : 57.3%의 비율로 각각 제작되어졌다. $109.73{\Omega}$를 목표 값으로 $25^{\circ}C$에서 자외선 레이저를 이용하여 가공한 결과, 82.3%가 가공오차가 ${\pm}0.03{\Omega}$이하에 들어왔으며 나머지 17.7%도 국제규격 A-Class내인 ${\pm}0.06{\Omega}$내에 포함되었다.

심미수복재의 수복방법과 광조사기기에 따른 치질과의 인장결합강도에 관한 연구 (A STUDY ON THE TENSILE BOND STRENGTH TO TOOTH STRUCTURE OF TOOTH COLORED MATERIALS ACCORDING TO FILLING METHODS AND LIGHT CURING UNITS)

  • 황호길;김영관;오행진
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.652-663
    • /
    • 1996
  • The purpose of this study was to evaluate the tensile bond strength to tooth structure of composite resin and glass ionomer cement according to filling methods and light curing units. In this study, two class V cavities were prepared on the buccal surface of each tooth of 140 extracted human molars, and they were randomly assigned into 3 experimental groups with 40 teeth and control group with 20 teeth. And then, each experimental groups subdivided into 2 groups(A,B) according to light curing units. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin(Group 1), Vitremer$^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the Vitrebond$^{TM}$ liner(Group 3). And subdivided A Group used Argon Laser(SPECTRUM$^{TM}$, U.S.A.), B Group used XL 1,000 curing light (3M, U.S.A.). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling, specimens were stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then, the tensile bond strength of specimens were calculated with Universal Testing Machine(AGS-100A, Japan). The results were as follows : 1. Among the experimental groups, the group 2-B showed the highest tensile bond strength ($18.89{\pm}7.80$) and the group 1-A showed the lowest tensile bond strength ($11.68{\pm}2.28$). There was significant difference between group 2-B and group 1-A(p<0.01). 2. Between the light curing units, the XL 1,000 unit showed higher tensile bond strength ($16.63{\pm}3.20$) than that of the Argon Laser unit ($13.73{\pm}2.30$). There was significant difference between XL 1,000 and Argon Laser(p<0.01). 3. About filling methods and materials, the group 2 showed the highest tensile bond strength ($17.56{\pm}1.89$) and the group 1 showed the lowest tensile bond strength($13.03{\pm}1.90$). There was significant difference between group 2 and group 1,3(p<0.01). In conclusion, the results showed that the glass-ionomer cement that cured by XL 1,000 light curing unit demonstrated significantly higher tensile bond strength than other curing unit and filling methods.

  • PDF

셀룰로오스 아세테이트 기반 어레이 촉각 액추에이터의 제작 및 특성평가 (Fabrication and Characterization of Array Tactile Actuator Based on Cellulose Acetate)

  • 김현찬;윤성률;고현우;김재환
    • 한국정밀공학회지
    • /
    • 제32권8호
    • /
    • pp.743-748
    • /
    • 2015
  • This paper reports the enhanced fabrication and characterization of a $3{\times}3$ array tactile actuator composed of cellulose acetate. The array tactile actuator, with dimensions of $15{\times}15{\times}1mm^3$, consists of 9 pillar-supported cells made from a cellulose-acetate molding. The fabrication process and performance test along with the results for the suggested actuator are explained. To improve the cell-array fabrication, a laser cut was adopted after the molding process. The displacement of the unit cell increased the input voltage and frequency. Various top masses are added onto the actuator to mimic the touch force, and the acceleration of the actuator is measured under actuation. When 2 kV is applied to the actuator, the maximum acceleration is 0.64 g, which is above the vibrotactile threshold. The actuation mechanism is associated with the electrostatic force between the top and bottom electrodes.

Measurement of Turbulent Intensity Distributions of a Cylinder Wake

  • Doh, Deog Hee;Cho, Gyeong Rae;Moon, Kyeong Rok;Cho, Yong Beom
    • 한국가시화정보학회지
    • /
    • 제11권1호
    • /
    • pp.41-47
    • /
    • 2013
  • Turbulence properties of a cylinder wake (d=10 mm) have been investigated with a new volume PTV algorithm. The measurement system consists of two-high-cameras(1 $k{\times}1$ k), a Nd-Yag laser and a host computer. A fitness function representing three-dimensional coherency has been adopted to sort out spurious vectors. A hybrid fitness function representing the relations between the fitness and the three-dimensional shortest distances constructed by the two collinears of the two cameras has been also adopted. The constructed algorithm has been employed for the measurements of the cylinder wakes. The Reynolds numbers tested in this paper are 360, 540, 720, 900, 1080 and 1260. More than 10,000 instantaneous 3D vectors have been obtained by the constructed system. The volumetric distributions of the turbulence intensities (for u', v', w') indicate that clearly different patterns for all Reynolds numbers and imply that a regular pattern (like a similarity rule) for the turbulent properties exists.

Terahertz Detection Characteristics of Low-Temperature Grown InGaAs/InAlAs Multi Quantum Well

  • 박동우;한임식;김창수;노삼규;지영빈;태인;이기주;김진수;김종수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.317-318
    • /
    • 2013
  • Terahertz (THz) wave는 광학 영역과 방송파 영역 사이에 광대역 주파수 스펙트럼을 차지하고 있다. X선과는 달리 비이온화 광원으로 직진성, 투과성, 낮은 에너지 (meV)를 가지고 있어 비파괴적이고 무해한 장점을 지니고 있다. 본 연구에서는 In0.53Ga0.47As:Be/In0.52Al0.48As의 multi quantum well (MQW)을 Semi-insulting InP:Fe substrate 위에 active layer의 두께와 적층을 변화주어서 성장하였고Au (200 nm)/Ti (30 nm)의 금속전극으로 공정을 하였다. Ti:Sapphire femtosecond pulse laser를 조사하여 THz time-domain spectrometer 시스템을 이용하여 광전도검출법으로 THz 검출 특성을 연구하였다. THz 검출은 짧은 전하수명과 높은 저항을 요구한다. LTInGaAs의 경우 AsGa antisite로 인하여 짧은 전하수명을 얻게 되면 n-type의 높은 전하밀도를 가지게 되어서 저항이 낮아지게 된다. 높은 저항을 만들기 위하여 Be doping을 이용하여 과잉의 전자들을 보상하고 InAlAs layer를 삽입시켜 보다 높은 저항을 얻었다. LT-InGaAs:Be는 LT-GaAs보다 1/70 정도의 amplitude를 보이는데 LT-InGaAs/InAlAs MQW의 경우 LT-GaAs 대비 약 3/4 정도의 큰 amplitude를 얻었다. 또 active layer의 두께가 얇고 적층이 많을수록 신호가 커지는 것을 알 수 있었다. 이는 상대적으로 band gap이 큰 InAlAs층이 더 높은 저항을 만든 것으로 사료된다.

  • PDF

AUTOMATIC MULTITORCH WELDING SYSTEM WITH HIGH SPEED

  • Moon, H.S;Kim, J.S.;Jung, M.Y.;Kweon, H.J.;Kim, H.S.;Youn, J.G.
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.320-323
    • /
    • 2002
  • This paper presents a new generation of system for pressure vessel and shipbuilding. Typical pressure vessel and ship building weld joint preparations are either traditional V, butt, fillet grooves or have narrow or semi narrow gap profiles. The fillet and U groove are prevalently used in heavy industries and shipbuilding to melt and join the parts. Since the wall thickness can be up to 6" or greater, welds must be made in many layers, each layer containing several passes. However, the welding time for the conventional processes such as SAW(Submerged Arc Welding) and FCAW(Flux Cored Arc Welding) can be many hours. Although SAW and FCAW are normally a mechanized process, pressure vessel and ship structures welding up to now have usually been controlled by a full time operator. The operator has typically been responsible for positioning each individual weld run, for setting weld process parameters, for maintaining flux and wire levels, for removing slag and so on. The aim of the system is to develop a high speed welding system with multitorch for increasing the production speed on the line and to remove the need for the operator so that the system can run automatically for the complete multi-torch multi-layer weld. To achieve this, a laser vision sensor, a rotating torch and an image processing algorithm have been made. Also, the multitorch welding system can be applicable for the fine grained steel because of the high welding speed and lower heat input compare to a conventional welding process.

  • PDF