• Title/Summary/Keyword: U-type test

Search Result 391, Processing Time 0.03 seconds

Evaluation of Heat Exchange Rate of Different Types of Ground Heat Exchangers (수직밀폐형 지중 열교환기 형태에 따른 열효율 평가)

  • Yoon, Seok;Go, Gyu-Hyun;Lee, Seung-Rae;Cho, Nam-Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2393-2400
    • /
    • 2013
  • This research presents an experimental study of heat exchange rate of U, W, 2U and coil type ground heat exchangers (GHEs) measured by thermal performance tests (TPTs). The four types of GHEs were installed in a partially saturated dredged soil deposit of Incheon International Airport area. Thermal response tests (TRTs) were conducted for U, W and 2U type GHEs to deduce the ground thermal conductivity. Besides, TPTs were also conducted for U, W, 2U and coil type GHEs to evaluate heat exchanger rates under 100-hr continuous and 8-hr intermittent operation conditions for five days. Coil shaped GHE showed about twice higher thermal performance than the others GHEs. Furthermore, intermittent operation condition showed 30~40% higher heat exchange rates than continuous operation condition.

Tensile Resistance and Field Application of Hang-type PC Beam (걸이형 PC보의 인장저항성 및 현장적용)

  • Ha, Sang-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.449-457
    • /
    • 2020
  • Due to the improvement of living standards and avoidance of the 3D industry, it is difficult to find young and competent domestic workers at construction sites, and most foreign workers are contributing to the replacement, but the quality is still deteriorating due to lack of skilled workers and aging. Precast method is a method that make members in factory and assembles them on site, which can be expected to improve labor force and quality. This study is intended to provide basic data for the development of hang-type PC beams that can be applied to the determination of the field application of developed PC beams. The U-type connecting material is installed on both ends of the hang-up PC beam, and the role of the U-type connecting material is very important because it is a simple construction method through the U-type connecting material. In addition, the performance of the U-type connecting material will determine the performance of the hang-type PC beam as the final destruction occurs in the hang-type PC beam. The material properties of U-type connecting material were identified through structural experiments, and the end test corresponding to the partial experiment was conducted based on the material test results identified. Finally, the final design value of PC beams was proposed through structural experiments for application to the site.

Factors Affecting Length of Stay and Death in Tuberculosis Patients(2008-2017): Focus on the Korean National Hospital Discharge In-depth Injury Survey (결핵 환자의 재원기간과 사망에 영향을 미치는 요인(2008-2017): 퇴원손상자료를 중심으로)

  • Lee, Hyun-Sook;Kim, Sang-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.487-497
    • /
    • 2021
  • The purpose of this study is to identify factors affecting length of stay(LOS) and death in tuberculosis(TB) patients by disease type, patient characteristic, admission and disease characteristic, and hospital characteristic from 2008 to 2017. Survey data was using Korean national hospital discharge in-depth survey data produced by Korea Disease Control and Prevention Agency. Study subjects were 10,634 inpatients with TB(A15, A16, A17, A18, A19, U88.0, U88.1, U84.30, U84.31) and analyzed frequency, chi-square test, Fisher's exact test, and logistic regression by using STATA 13.0. As a study result, the type of TB(extrapulmonary TB, multidrug-resistant TB, extensively drug-resistant TB), sex(woman), age(35-49, 50-64, 65-74, 75 years old or older), admission type(outpatient department), CCI(1-2 point, 3 point over), hospital location(metropolitan city) and bed size(300-499, 500-999, over 1000) were significantly influence LOS. Also, the type of TB(extrapulmonary TB, extensively drug-resistant TB), sex(woman), age(50-64, 65-74, 75 years old or older), residence(small town/rural), admission type(outpatient department), CCI(1-2 point, 3 point over), hospital location(provincial) were significantly influence death. In conclusion, the existing tuberculosis management has been patient management with rapid diagnosis and treatment following early detection. But other studies should be carried out for the system that identifies and supports high-risk groups of the long-term length of stay in hospital or high mortality rates as a result of treatment.

5kg $U_3O_8$/Batch Scale Mock-up Test for the Electrochemical Reduction of Spent Oxide Fuel (사용후핵연료의 전기화학적 금속전환을 위한 5kg $U_3O_8$/Batch 규모의 Mock-up시험)

  • 오승철;허진목;홍순석;이원경;서중석;박성원
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.358-362
    • /
    • 2003
  • An electrochemical reduction technology which can reduce the decay heat, volume, and radioactivity of spent fuel by a factor of quarter by converting oxide type spent fuel to a metallic form in a molten salt was developed and mock-up test in a 5kg $U_3O_8$/batch scale was carried out. The electrochemical reaction was analyzed regarding the operational factors. The research efforts was also concentrated on the apparatus development for a hot test. Fresh $U_3O_8$ powder was metallized with a more than 99% yield via this electrochemical technology and design data for the 20kg $U_3O_8$/batch scale apparatus were also obtained.

  • PDF

A Performance Test on Exterior T-type Joint for RCS Composite System (철근콘크리트 기둥 철골 보의 합성구조 외부형 접합부 구조성능에 관한 연구)

  • 양승렬;이상호;김병국;정하선;김종락;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.977-982
    • /
    • 2000
  • As a newly structural system, RCS composite system has been researched last two decades. However mechanism of exterior T-type joint for RCS composite system is not well known. This research is focus on the exterior T-type joint for RCS composite system. Specimens are designed by the ASCE guideline, tested and compared with the inner RCS joint. Test variables include face bearing plate(FBP), extended face bearing plate(E-FBP) and U-bar. The tests indicate that the strength of exterior T-type joint is higher than that of the guideline by ASCE. The U-bar has a significant effect on the joint strength and absorbing the strain energy.

Evaluation of performance of closed-loop vertical ground heat exchanger by In-situ thermal response test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Kwak, Tae-Hoon;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.229-239
    • /
    • 2010
  • Performing a series of in-situ thermal response tests, the effective thermal conductivity of six vertical closed-loop ground heat exchangers was experimentally evaluated and compared each other, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than that of bentonite grouting, and the efficiency of graphite better performs over silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance.

  • PDF

5kg $U_{3}O_{8}$ Batch Scale Mock-up Test for the Electrochemical Reduction of Spent Oxide Fuel (사용후핵연료의 전기화학적 금속전환을 위한 5kg $U_{3}O_{8}$ Batch 규모의 Mock-up 시험)

  • 오승철;허진목;홍순석;이원경;서중석;박승원
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 2003
  • An electrochemical reduction technology which can reduce the decay heat, volume, and radioactivity of spent fuel by a factor of quarter through converting oxide type spent fuel to a metallic form in a molten salt was developed and tests in a scale of g (3- 40g $U_{3}O_{8}$ batch) have been carried out by Korea Atomic Energy Research Institute. In this research, the reaction apparatus in a scale of 5kg $U_{3}O_{8}$ batch was designed and manufactured for the mock-up test to obtain design data of the apparatus which will be used for the hot test in a scale of 20kg $U_{3}O_{8}$ batch. The electrochemical reduction behavior of $U_{3}O_{8}$ was analyzed regarding the operational factors and fresh $U_{3}O_{8}$ powder was metallized with a more than 99% yield verifying the process validity of electrochemical reduction process in a kg scale.

  • PDF

Effects of Blending Fatty Acid-Glycerol-pMDI with Urea-Formaldehyde Resin Adhesives to Their Adhesion for the Use of Soybean Oil (콩기름 이용을 위한 지방산-글리세롤-pMDI와 요소수지 혼용 접착제가 접착성능에 미치는 영향-)

  • You, Young-Sam;Choi, Jin-Lim;Seo, Jun-Won;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.31-36
    • /
    • 2006
  • This study was conducted to improve the bond strength of plywood bonded with F/U molar ratio urea-formaldehyde (UF) resins modified with the selected FGMDI prepolymer contents for various purposes. The amount of FGMDI was mixed with liquid UF resin at 0 wt% (as control), 2 wt%, 5 wt%, 10 wt%, 25 wt%, and 50 wt% based on the resin solids. As results, in bonding strength, plywood with F/U molar ratio of 1.4 showed the highest value in Type 2 test and all molar ratio UF resins modified with over 25 wt% of the FGMDI showed more than $11kgf/cm^2$, which was satisfied the minimum requirement of KS standard, $7.5kgf/cm^2$, after Type1.5 testing. As F/U molar ratio was increased and the FGMDI addition in the UF resin was increased, average reduction rate of Type 1.5 bonding strength compared with Type 2 was significantly decreased.

Comparison of Flow Characteristics for the Development of a C-Type Strainer with Its Inlet and Outlet on a Straight Line (유입·유출구가 일직선상인 C형 스트레이너 개발을 위한 유동특성 비교)

  • Shin, Byung-kyun;Kwon, Chang-Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.257-265
    • /
    • 2016
  • The purpose of this study was to develop a strainer that could protect a flow system by blocking the introduction of foreign substances into the pipe of industrial or architectural facilities. Strainers are installed at the front tip of valves, machines, or pumps in the piping line of clean water, oil, or gas. There are Y-type, U-type, and T-type strainers. The study identified problems with the Y-type strainers, develop a "C-type strainer with its inlet and outlet on a straight line" as a more improved new model, and compared them in functions in a full-scale strainer test. The study conducted a full-scale strainer test according to four situations at the flow laboratory of Korea Research Institute of Standards and Science by using the old Y-type strainer and C-type strainer 50A. The test results show that the C-type strainer had a higher capacity coefficient(Kv) than the Y-type one, recording 74.9% when there was no screen, 54.5% when there were no foreign substances in the screen, 54.2% when there was a 15% accumulation of foreign substances, and 52.4% when there was a 30% accumulation of foreign substances. The investigator conducted a test only with the 50A type due to the limitations of life-size strainers, but the results demonstrate that the C-type strainer had better flow characteristics than the Y-type one.