• Title/Summary/Keyword: U-tubes

Search Result 135, Processing Time 0.027 seconds

Pharmacognostical Evaluation of Gymnema sylvestre R. Br.

  • Agnihotri, Adarsh Kumar;Khatoon, Sayyada;Agarwal, Manisha;Rawat, Ajay Kumar Singh;Mehrotra, Shanta;Pushpangadan, Palpu
    • Natural Product Sciences
    • /
    • v.10 no.4
    • /
    • pp.168-172
    • /
    • 2004
  • In India, Gymnema sylvestre due to the unique property of the plant to antagonize the sweet taste is known as 'Gur-mar'. It has several ethnomedicinal values as various tribals/traditional communities and rural peoples of India find diverse medicinal uses viz. antidiabetic, stomachic, diuretic, and is useful in cough and throat troubles. Besides, it has strong effect on reducing blood sugar. The present communication deals with the detailed pharmacognostical evaluation of the aerial parts of G. sylvestre collected from three places of the country-Varanasi (U.P), Panchmarhi (M.P), Salem (Tami Nadu) and commercial sample procured from local market. The botanical and physico-chemical parameters of all the samples were quite similar though little variations were observed in foaming index, alcohol and water soluble extractives of local sample. The microscopic characteristics of the drug are horse shoe shaped petiole with 3 amphicribal vascular bundles, sieve tubes well developed; anomocytic stomata only on the abaxial surface of the leaf, the fan shaped amphicribal vascular bundle, presence of intraxylary phloem. The TLC fingerprint profile of all the samples was more or less similar only the quantity of some of the compounds varied.

Location of pressure sensing holes in MPA flowmeter and discharge coefficients (MPA 유량계 압력감지공의 위치와 유출계수)

  • Kim, Raymond K.;Choi, Sung Kil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

Post Test Analysis to Natural Circulation Experiment on the BETHSY Facility Using the MARS 1.4 Code

  • Chung, Young-Jong;Kim, Hee-Cheol;Chang, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.638-651
    • /
    • 2001
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic code, MARS 1.4, for the analysis of thermal-hydraulic behavior in PWRs during natural circulation conditions. The code simulates a natural circulation test, BETHSY test 4. la, which was conducted on the integral test facility of BETHSY. The test represented the cooling states of the primary cooling system under single-phase natural circulation, two-phase natural circulation and the reflux condensation mode with conditions corresponding to the residual power, 2% of the rated core power value and 6.8 MPa at the secondary system. Based on MARS 1.4 calculations, the major thermal-hydraulic behaviors during natural circulation are evaluated and the differences between the experimental data and calculated results are identified. The calculated results show generally good behavior with regard to the experimental results; the region of single-phase natural circulation is 100-92% of the initial mass inventory, two-phase natural circulation is 84-63 %, and the reflux condensation mode occurred below 58 %. U-tubes empty and the core uncovery are obtained at 39 % and 34 % of the initial mass inventory, respectively.

  • PDF

Distributions of the velocity and pressure of the pulsatile laminar flow in a pipe with the various frequencies (주파수의 변화에 따른 원형관로내 층류맥동유동의 속도와 압력의 분포)

  • Bae, S.C.;Mo, Y.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.561-571
    • /
    • 1997
  • In this paper, the fundamental equations are developed for the pulsatile laminar flow generated by changing the oscillatory flow with $0{\leq}f{\leq}48Hz$ into a steady one with $0{\leq}Re{\leq}2500$ in a rigid circular pipe. Analytical solutions for the wave propagation factor k, the axial distributions of cross-sectional mean velocity $u_m$ and pressure p are schematically derived and confirmed experimentally. The axial distributions of centerline velocity and pressure were measured by using Pitot-static tubes and strain gauge type pressure transducers, respectively. The cross-sectional mean velocity was calculated from the centerline velocity by applying the parabolic distribution of the laminar flow and it was confirmed by using the ultrasonic flowmeter. It was found that the axial distributions of cross-sectional mean velocity and pressure agree well with theoretical ones and depend only on the Reynolds number Re and angular velocity $\omega$.

  • PDF

A Study on the Pressure Loss in Helically Coiled Tubes (나선코일 튜브 내에서의 압력손실에 관한 연구)

  • Han, K.I.;Bark, J.U.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF

Inelastic stability analysis of high strength rectangular concrete-filled steel tubular slender beam-columns

  • Patel, Vipulkumar Ishavarbhai;Liang, Qing Quan;Hadi, Muhammad N.S.
    • Interaction and multiscale mechanics
    • /
    • v.5 no.2
    • /
    • pp.91-104
    • /
    • 2012
  • There is relatively little numerical study on the behavior of eccentrically loaded high strength rectangular concrete-filled steel tubular (CFST) slender beam-columns with large depth-to-thickness ratios, which may undergo local and global buckling. This paper presents a multiscale numerical model for simulating the interaction local and global buckling behavior of high strength thin-walled rectangular CFST slender beam-columns under eccentric loading. The effects of progressive local buckling are taken into account in the mesoscale model based on fiber element formulations. Computational algorithms based on the M$\ddot{u}$ller's method are developed to obtain complete load-deflection responses of CFST slender beam-columns at the macroscale level. Performance indices are proposed to quantify the performance of CFST slender beam-columns. The accuracy of the multiscale numerical model is examined by comparisons of computer solutions with existing experimental results. The numerical model is utilized to investigate the effects of concrete compressive strength, depth-to-thickness ratio, loading eccentricity ratio and column slenderness ratio on the performance indices. The multiscale numerical model is shown to be accurate and efficient for predicting the interaction buckling behavior of high strength thin-walled CFST slender beam-columns.

Development and Validation of MARS-KS Input Model for SBLOCA Using PHWR Test Facility (중수로 실증 실험설비를 이용한 소형냉각재상실사고의 MARS-KS 입력모델 개발 및 검증계산)

  • Baek, Kyung Lok;Yu, Seon Oh
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.111-119
    • /
    • 2021
  • Multi-dimensional analysis of reactor safety-KINS standard (MARS-KS) is a thermal-hydraulic code to simulate multiple design basis accidents in reactors. The code has been essential to assess nuclear safety, but has mainly focused on light water reactors, which are in the majority in South Korea. Few previous studies considered pressurized heavy water reactor (PHWR) applications. To verify the code applicability for PHWRs, it is necessary to develop MARS-KS input decks under various transient conditions. This study proposes an input model to simulate small-break loss of coolant accidents for PHWRs. The input model includes major equipment and experimental conditions for test B9802. Calculation results for selected variables during steady-state closely follow test data within ±4%. We adopted the Henry-Fauske model to simulate break flow, with coefficients having similar trends to integrated break mass and trip time for the power supply. Transient calculation results for major thermal-hydraulic factors showed good agreement with experimental data, but further study is required to analyze heat transfer and void condensation inside steam generator u-tubes.

RELAP5 Analysis of the Loss-of-RHR Accident during the Mid-Loop Operation of Yonggwang Nuclear Units 3/4

  • J. J. Jeong;Kim, W. S.;Kim, K. D.;W. P. Chang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.403-410
    • /
    • 1995
  • A loss of the residual heat removal (RHR) accident during mid-loop operation of Yong-gwang Nuclear Units 3/4 was analyzed using the RELAP5/MOD3.1.2 code. In this work the following assumptions are used; (i) initially the reactor coolant system (RCS) above the hot leg center line is filled with nitrogen gas, (ii) two 3/4-inch diameter vent valves on the reactor vessel head and the top of pressurizer in the reactor coolant system are always open, and a level indicator is connected to the RMR suction line, (iii) the two steam generators are in wet layup status and the steam generator atmospheric dump valve assemblies are removed so that the secondary side pressure remains at nearly atmospheric condition throughout the accident, and (iv) the loss of RHR is presumed to occur at 48 hours after reactor shutdown. Findings from the RELAP5 calculations are (i) the core boiling begins at ∼5 min, (ii) the peak RCS pressure is ∼3.0 bar, which implies a possibility of temporary seal break, (iii) ∼94 % of the decay heat is removed by reflux condensation in the steam generator U-tubes in spite of the presence of noncondensable gas, (iv) the core uncovery time is evaluated to be 7.2 hours. Significant mass errors were observed in the calculations.

  • PDF

Identification and prevalence of trematode(Gen Azygia) and nematode(Gen Pingus) in Ophicephalus argus (가물치의 위장내 기생하는 흡충(Azygia속) 및 선충(Pingus속)의 동정과 감염상황)

  • Moon, Moo-hong;Lee, Eun-woo
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.1
    • /
    • pp.147-159
    • /
    • 1998
  • A survey of the internal parasites in 115 fishes of Ophicephalus argus was carried out in Kyungpook province during the period from January 1995 to November 1997. A species of trematode from the stomach and a species of nematode from the caeca of the fishes was discovered respectively. The trematode was identified as Azygia hwangtsinyi (Tsin, 1993) and the nematode as Pingus sinensis ($Hs\ddot{u}$, 1993). The fluke was pressed at thick of 0.1mm~0.2mm between slide glasses and fixed in 70% ethyl alcohol solution. The fluke was washed with tap water after fixation and stained with hematoxylin-carmin and mounted in balsam through routine methods. The nematode was fixed in 5% formalin solution and mounted with lactophnol or glycerine jelly. Morphology : Arygia hwantsinyi ; The fluke is elongate body with approximately parallel margins and rounded extremities in pressed preparations(Fig 1). The cuticle is unarmed. The oral sucker is ventro-subterminal in position. The ventral sucker is slightly smaller than oral sucker and positioned at 14.2% of body length from the oral sucker. The cirrus sac and genital pore is in mid-ventral line, slightly anterior to the ventral sucker. The oral sucker is succeeded by a well developed muscular pharynx. It is succeeded by a short inverted Y-shaped oesophagus. The inner wall of oesophagus is consisted of many fine folded membrane. The fine tubes of esophagus pass into the intestinal heads which are distended and presented a marked borderline between the fine tube and intestinal heads. The Intestinal heads start at level of pharynx and pass caudad in a zigzag course to end quite near caudal margin. The uterine coils occupy the intercecal area between the level of the cephalic margin of the ovary and about the level of the ventral sucker. The uterus is filled with many eggs. The testes are round or oval and placed one behind the other generally a little diagonally. The posterior testis is placed at level of 75.1% of body length. The ovary is oval, placed ahead the anterior testis. The shell gland not discernible outline is contacted with ovary ahead it. The vitelline glands are consisted of small oval vesicles. The vesicles occupy extracecal regions and between a little posterior of the ventral sucker and near caudal margin. Pingus sinensis : Female ; The cuticle is smooth and the cervical alae are well developed. The mouth opening is small, triangular, and without lips. The anterior end bears four sub-medial papillae. The oesophagus is divided into a muscular and glandular portion. The nerve ring is situated just at the junction of the muscular and glandular portions of the oesophagus. The vulva which has a prominent flap, is placed behind the middle of the body about one-third of the length of the worm from the posterior extremity. The vagina is strongly muscularised and after running anteriorly about $68{\mu}$, divides itself into two broad uterine tubes with an anterior and a posterior one. There are a few eggs in the uterine tubes. The tail is slender, straight and pointed. The ovary extends almost to the posterior extremity. Male : Male is smaller than female. The tail is pointed, curved and carrying well-developed caudal alae. A prominent muscular precloacal sucker is characteristic. The spicules are equal and short. There are four pairs of pedunculated pre-anal papillae, of which the most anterior pair are situated just at the level anterior to the muscular sucker. Two pairs of pedunculated papillae are present before the anus. There are five pairs of post-anal papillae of which the most anterior pair and the second counted from the posterior end are ventral and more marked than the ones which are situated laterally.

  • PDF

Forced Convection Modelling of a Solar Central Receiver using Nonisothermal Cylinders in Crossflow (비등온 실린더 모델을 이용한 태양로의 강제 대류에 의한 열 손실 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Jeon, Hong-Seok;Auh, P. Chung-Moo;Boehn, Robert F.
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.13-18
    • /
    • 1990
  • When nonuniform thermal boundary conditions are imposed on the surface of a circular cylinder in crossflow, the heat transfer characteristics can be quite different compared to what is found for isothermal or constant heat flux boundary conditions. In the present analysis, two kinds of nonuniform boundary conditions along the circumference of the cylinder are considered in a uniform stream of air: step changes and linear profiles. Step changes in temperature can arise on the surface of an external, cylindrical, solar central receiver. As the working fluid(water) flows through the vertical tubes that ring the circumference of Solar One(a solar central receiver in Barstow, California), the solar flux on the receiver heats the water from a liquid to a superheated state. In this process, portions of the receiver panels, and thus portions of the circumference of the cylinder, function as a preheater, boiler, or superheater. Hence the surface temperature can vary significantly around the cylinder. Common engineering practice has been to use an average wall temperature with an isothermal cylinder heat transfer coefficient when estimating the convective loss in these kinds of situations.

  • PDF