• 제목/요약/키워드: U-cooler

검색결과 21건 처리시간 0.027초

FAST irradiations and initial post irradiation examinations - Part I

  • G. Beausoleil;L. Capriotti;B. Curnutt;R. Fielding;S. Hayes;D. Wachs
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4084-4094
    • /
    • 2022
  • The Advanced Fuels Campaign Fission Accelerated Steady-state Test (FAST) at Idaho National Laboratory (INL) completed its first irradiation cycle within the Advanced Test Reactor (ATR). The test focused on the irradiation of alloy fuel forms for use in sodium fast reactors. The first cycle of FAST testing was completed and four rodlets were removed for the initial post irradiation examination (PIE). The rodlet design and irradiation conditions were evaluated using Monte Carlo N-Particle (MCNP) for as-run power history and COMSOL for temperature analysis. These rodlets include a set of low burnups (~2.5 % fissions per initial metal atoms [%FIMA]), control rodlets, and a helium-bonded annular rodlet (4.7 %FIMA). Nondestructive PIE has been completed and includes visual inspection, neutron radiography and gamma scanning of the FAST capsules and rodlets. Radiography confirmed the integrity of the experiments, revealed that the annulus in the annular fuel was filled at a modest burnup (4.7 %FIMA), and indicated potential slumping of the cooler rodlets at lower burnup. Precision gamma scanning indicated mostly usual fission product behavior, except for cesium in the He-bonded annular fuel. Future destructive PIE will be necessary to fully interpret the effects of accelerated irradiation on U-Zr metallic fuel behavior.

UBV Light Curves of AR Lacertae During 1980-'81 and 1981-'82

  • Nha, Il-Seong;Park, Hong-Suh;Kang, Young-Woon;Wood, Frank-Bradshaw;Williamon, Richard-M.;Leviton, Douglas-B.
    • Journal of Astronomy and Space Sciences
    • /
    • 제2권2호
    • /
    • pp.69-99
    • /
    • 1985
  • The UBV observations of the Brightest RS CVn-type eclipsing binary star AR Lac were made at four observatories, two in Korean and two in the U.S. in the 1980-81 and 1981-82 seasons. As a result of the cooperation, two light curves in the yellow and in the blue were completed for each observing seasons. Ultraviolet observations were also made at three of the four observatories. The orbital period of AR Lac apparantly decreased around 1977. An analysis of our yellow light curves together with five other yellow curves available in the literature since 1975 shows that there seems no periodicity in the migration of the distortion waves. There is a gradual decrease of at least 0.m1 between 1976 and 1982 in the brightness of the cooler component if one assumes that the hotter component is constant.

  • PDF

기술현황분석 - 가스 바이패스(Gas Bypass) 사이클을 적용한 오일쿨러(Oil cooler) 연구

  • 염한길;이승우;박길종
    • 기계와재료
    • /
    • 제22권1호
    • /
    • pp.54-64
    • /
    • 2010
  • 공작기계의 고속화, 다축화, 복잡화에 따른 열변형 오차가 공작기계에서 발생하는 오차의 대부분을 차지하고 있다. 이러한 열변형 오차를 최소화 하기 위해 공작기계의 발열부에 차가운 오일을 공급하여 냉각함으로써, 열변형을 제거하는 장치가 오일쿨러이다. 오일쿨러는 제어 방법에 따라 On-off, 가스 바이패스, 인버터 방식 등이 사용된다. 초정밀 공작기계에는 주로 가스 바이패스 및 인버터 방식이 사용되는데, 인버터 방식의 경우 고가(高價)인 관계로 주로 옵션 형태로 사용된다. 가스 바이패스 방식 오일쿨러는 인버터 방식에 비해 가격이 저렴하고 구조가 간다하며 정밀한 온도제어를 할 수 있지만 부하가 낮은 경우 구조적인 한계로 인해 온도제어 불안정을 발생시킨다. 본 연구에서는 기존 바이패스 방식 오일쿨러에서 나타나는 문제점을 해결하고 보다 정밀한 온도제어를 위해 2개의 전자밸브를 갖는 듀얼 밸브 방식 오일쿨러 시스템을 개발하였다. 개발된 듀얼 밸브 오일쿨러 시스템의 성능검증을 위해 정격운전, DIN 8602 규격, ISO/DIS 230-3 운전모드에서 성능을 비교/분석하였다.

  • PDF

CO2 압축기의 운전조건과 오일토출의 상관분석에 관한 실험적 연구 (An Experimental Study on Correlation between Oil Discharge and Various Operating Conditions of a CO2 Compressor)

  • 이익수;강병하
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 2011
  • A portion of oil for lubrication of compressor flows together with refrigerant in the refrigeration system. If the oil discharge from a compressor is increased in the refrigeration system, not only pressure drop is increased in other components, such as evaporator and gas cooler, but also heat transfer coefficient in the heat exchangers is decreased. Oil discharge rate from a compressor may strongly depend on operating conditions of a compressor. In this study, one stage single rotary compressor is employed for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Oil circulation ratio(OCR) can be estimated by measured mixture density. The results obtained indicate that the oil circulation ratio(OCR) is increased as the suction temperature or compressor operating frequency is increased. Oil circulation ratio(OCR) correlation of the compressor is also suggested.

폐기물 열분해 합성가스를 이용한 발전용 엔진구동에 대한 실험적 연구 (An Experimental Study on the Operation of a Power Generation Engine with Syngas from RPF)

  • 정효재;이정우;이재욱;문지홍;최인수;박상신;황정호;류태우;이은도
    • 한국연소학회지
    • /
    • 제15권3호
    • /
    • pp.48-56
    • /
    • 2010
  • Performances of power generation engine were investigated with syngas from RPF. A stoker type, multi-staged pyrolysis-gasification system, was employed for syngas generation and the syngas was refined with the sequential cleaning processes composed of a gas cooler, a bag filter and a wet scrubber. 20 kWe commercial syngas power generation engine was adopted to burn the cleaned syngas which is mainly composed of hydrogen, carbon monoxide, carbon dioxide and methane. The performance of the engine was tested with various syngas compositions and the results were compared to LNG case. Electric power output, exhaust gas temperature, and emission characteristics were measured, and the efficiency of engine generation was investigated as a function of load of power generation.

$CO_2$ 냉동시스템에서 압축기의 흡입온도와 운전주파수가 오일 순환량에 미치는 영향 (Effect of Suction Temperature and Compressor Frequency on Oil Circulation Ratio in a $CO_2$ Refrigeration System)

  • 김경재;이익수;강병하;김석현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.893-898
    • /
    • 2009
  • The quantity of discharged oil from a compressor is one of the most important issues for proper operation of refrigeration system. If the oil is increased in the system not only pressure drop is increased in other components, such as evaporator and gas cooler but also heat transfer coefficient in the heat exchangers is decreased. In addition, the lack of oil in the compressor may cause a critical of the system failure. In this study, one stage single rotary compressor is used for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Characteristics of oil circulation ratio have been investigated for $CO_2$ rotary compressor in the range of operation frequency 45 Hz to 63 Hz and the suction temperature range of $0^{\circ}C$ to $15^{\circ}C$. The results obtained indicate that the oil circulation ratio is increased as the suction temperature or compressor operating frequency is increased.

  • PDF

글라스가 와인 테이스팅에 미치는 영향 -리델 글라스를 중심으로- (A Study on the Effect of Wineglass to the Wine Tasting -Focussing on Riedel Glass-)

  • 이유주
    • 한국조리학회지
    • /
    • 제10권1호
    • /
    • pp.64-81
    • /
    • 2004
  • Recently, the demand for utensils related to wine business has been growing from the wine consumers in Korea in order to enjoy flavor of wine more profoundly. This study propose a theory about the five senses that had been issued frequently in wine world attracting an attention of ever-changing food culture. In addition, it is to help sommeliers and devotes to learn the knowledge about the wine. To fully appreciate the different grape varieties and the subtle characteristics of wines, it is essential to have a glass with shape if fine-tuned for the purpose. The shape is responsible for the quality and intensity of the bouquet and the flow of the wine. This study has been performed with Riedel glass that has been appreciated as one of the finest wineglass in the world to investigate the effect of glass to the wine tasting. This study should be followed by further study with other tasting glass such as INAO and Le Taster glass to be generalized. The study is also needed about not only wineglass but wine accessories such as cork-screw, decanting and wine cooler.

  • PDF

색의 속성에 따른 지각된 온도감과 판단 왜곡 (The effect of color on apparent warmth and judgment distortion)

  • 김문주;한광희;이주환
    • 감성과학
    • /
    • 제9권4호
    • /
    • pp.341-351
    • /
    • 2006
  • 색은 인간에게 어떤 느낌을 전달하기도 하고 행동에 영향을 미치기도 한다. 특히 적절히 적용된 색은 제품의 품질과 사용성을 향상시키기 때문에 색의 효과에 대한 이해와 신중한 사용이 중요하다. 그러므로 본 연구에서는 온도감에 대한 색의 3요소(색상, 명도, 채도)의 효과와 그 관계를 정확히 이해하고 정보 디스플레이에 적용할 수 있는 응용적 가치를 탐색하고자 하였다. 색상환에 따른 10가지 색상의 온도감은 U 모양으로 나타났는데 빨강에서 가장 높고 파랑과 남색에서 가장 낮았으며, 채도는 색상이 가지는 온도감의 특징을 더 두드러지게 한 반면, 명도의 효과는 없었다. 이 결과는 색의 사용에 제한이 있는 상황에서도 채도의 다른 요소를 조절함으로써 온도감에 변화를 줄 수 있음을 보여준다. 한색과 난색의 구분은 명확하였으며 이러한 색의 주관적 온도감 차이로 인해 참가자들은 그래프 판독에서 실제의 온도보다 더 따뜻하거나 더 차갑다고 보고하는 온도계 측정에서의 판단 왜곡을 보였다. 이런 차이는 과제와 디스플레이 특성에 맞게 색의 구성요소들의 민감도를 조절하는데 적용할 수 있을 것이다.

  • PDF

MIRIS 지구관측 적외선카메라 인증모델 성능 시험 및 Field Test

  • 문봉곤;박영식;이창희;박성준;차상목;이대희;정웅섭;남욱원;박장현;육인수;가능현;이미현;이덕행;양순철;김영주;이기훈;정한;이승우;한원용
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2009년도 한국우주과학회보 제18권2호
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 과학기술위성 3호의 주탑재체인 MIRIS (Multi-purpose InfraRed Imaging System)는 우주관측카메라 (Space Observation Camera, SOC)와 지구관측카메라 (Earth Observation Camera, EOC)가 독립적인 시스템으로 구성되어 있다. 지구관측카메라는 유효 구경 100 mm, F/5의 광학계로 3-5 마이크론 파장영역을 관측하며, 국내에서 개발된 적외선 검출기의 우주 인증 시험과 유사시 한반도 적외선 감시를 주요 목적으로 하고 있다. 고도 700km에서 지상을 볼 때 약 42m/pixel의 공간분해능을 나타낼 것으로 기대하고 있다. 지구관측카메라의 인증 모델(Qualification Model)은 냉동기를 제외한 모든 부품이 국내기술로 제작되었으며, 미러 본딩 및 릴레이 렌즈 조립 기술, 적외선 영상 검교정 기술 등 다양한 경험과 도전을 제공했다. 이 발표에서는 지구관측카메라 인증모델을 이용하여 수행한 주요 시험 과정을 소개한다. 국내 회사 (주)i3 system에서 제작된 적외선 검출기는 $320\times256$ HgCdTe array (평균 양자효율 80% 이상) 이며 77K에서 정상적으로 운영된다. Micro Stirling Cooler에 의해 듀어는 전원을 켠 후 5분 이내에 검출기 운영온도인 77K까지 내려간다. 적외선 광학계의 정렬, 시스템 MTF 측정, 흑체 측정 및 검교정 작업을 수행한 후 야외에서 다양한 경우에 대해 Field Test를 진행했다. 이 발표에서는 Field Test 과정과 이를 통해 얻은 결과를 발표하고, FM (Flight Model) 제작에 있어 수정해야 할 사항들을 제안해 본다.

  • PDF

MIRIS 우주관측카메라의 기계부 개발 (DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC)

  • 문봉곤;정웅섭;차상목;이창희;박성준;이대희;육인수;박영식;박장현;남욱원;;;양순철;이선희;이승우;한원용
    • 천문학논총
    • /
    • 제24권1호
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.