• Title/Summary/Keyword: U-beam

Search Result 481, Processing Time 0.027 seconds

Post etch process using CO/NH3 and Reactive Ion Beam for STT-MRAM device

  • Park, Seong-U;Yang, Gyeong-Chae;Jeon, Min-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.38-38
    • /
    • 2015
  • 차세대 메모리로 각광받고 있는 STT-MRAM의 동작특성을 향상시키기 위하여 식각 시 재 증착되는 식각 부산물을 저 손상을 제거하였다.

  • PDF

A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy (확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구)

  • Lee, Jeong-U;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

Experimental study on replaceable precast concrete beam-column connections

  • Seung-Ho Choi;Sang-Hoon Lee;Jae-Hyun Kim;Inwook Heo;Hoseong Jeong;Kang Su Kim
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2024
  • The purpose of this study was to develop a system capable of restoring the seismic performance of a precast concrete (PC) connection damaged by an earthquake. The developed PC connection consists of a top-and-seat angle, post-tensioning (PT) tendons, and U-shaped steel. The PC beam can be replaced by cutting the PT tendons in the event of damage. In addition, the seismic performance of the developed PC beam-column connection was evaluated experimentally. A PC beam-column connection specimen was fabricated, and a quasistatic cyclic loading test was conducted to a maximum drift ratio of 2.3%. Subsequently, the PC beam was replaced by a new PC beam, and the repaired PC connection was loaded to a maximum drift ratio of 5.1%. The structural performance of the repaired PC connection was then compared with that of the original PC connection. The difference in the load at the drift ratio of 2.3% between the original and the repaired PC specimens was only 0.2%. The residual drift ratio in the repaired PC specimen did not exceed 1.0% at the 2.0 % drift ratio cycles, which satisfies the life safety performance level specified in ACI 374.2R-13. When the developed PC connection system is used, structural performance can be restored by rapidly replacing the damaged elements.

A Stability Analysis for Vehicle Impact in U-Channel Segmental Concrete Bridges (U-채널 세그멘탈 콘크리트 교량의 차량충돌에 대한 안전성 분석)

  • Choi, Dong-Ho;Na, Ho-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.17-25
    • /
    • 2010
  • This paper studied on stability of the U-channel segmental concrete bridge under vehicle-impact loads. The U-channel bridge has advantages in that it reduces an additional dead load and the edge beams role as a barrier. But it has a dangerous factor which collapses the bridge structure when the edge beams are ruptured. Therefore, it is necessary to verify behaviors of the bridge system under vehicle-impact loads. Static and dynamic vehicle impact simulations were carried out on the basis of AASHTO LRFD design specifications. In case of the static analysis, equivalent static loads specified in the AASHTO codes are loaded on the edge beams and in case of the dynamic analysis, FEM vehicle models are modeled by applying the dynamic test specifications of AASHTO codes. As a result, it is shown that U-channel bridge system has sufficient safety against static and dynamic impact loads specified in the AASHTO LRFD design specifications.

Finite Element Analysis for Electron Optical System of a Thermionic SEM (열전자방사형 주사전자 현미경 전자광학계의 유한요소해석)

  • Park, Keun;Jung, Huen-U.;Kim, Dong-Hwan;Jang, Dong-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1288-1293
    • /
    • 2007
  • The present study covers the design and analysis of a thermionic scanning electron microscope (SEM) column. The SEM column contains an electron optical system in which electrons are emitted and moved to form a focused beam, and this generates secondary electrons from the specimen surfaces, eventually making an image. The electron optical system mainly consists of a thermionic electron gun as the beam source, the lens system, the electron control unit, and the vacuum unit. In the design process, the dimension and capacity of the SEM components need to be optimally determined with the aid of finite element analyses. Considering the geometry of the filament, a three-dimensional (3D) finite element analysis is utilized. Through the analysis, the beam emission characteristics and relevant trajectories are predicted from which a systematic design of the electron optical system is enabled. The validity of the proposed 3D analysis is also discussed by comparing the directional beam spot radius. As a result, a prototype of a thermionic SEM is successfully developed with a relatively short time and low investment costs, which proves the adoptability of the proposed 3D analysis.

  • PDF

Facet Growth of InGaAs on GaAs(100) by Chemical Beam Epitaxy Using Unprecracked Monoethylarsine (GaAs(100) 기판에 사전 열분해하지 않은 Monoethylarsine을 사용하는 Chemical Beam Epitaxy방법에 의한 InGaAs박막의 Facet 성장에 관한 연구)

  • 김성복;박성주;노정래;이일항
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.199-205
    • /
    • 1996
  • InGaAs eqitaxial layers have been selectively grown on patterned GaAs(100) substrates by chemical beam epitaxy (CBE) using triethylgallium (TEGa), trimethylindium (TMIn), and unprecracked monoethylarsine (MEAs). Facet growth of InGaAs epilayers has also been investigated at the various growth temperatures and Si4N4 dielectric pattern directions. In [011] jirection of mask, the change from (311), (377) and (111) facets to (311) facet with increasing growth temperature was observed. In [011] direction, however, the change from (011) and (111) facets to (111) facet with increasing growth temperature was observed. These results are attributed to the sidewall growth caused by different surface migration lengths of reactants. The formation of U-shaped (100) top surface is also discussed in terms of dangling bond model.

  • PDF

Improvement for Hearing Aids System Using Adaptive Beam-forming Algorithm (적응 빔포밍 기법을 적용한 보청기 시스템의 성능 향상에 관한 연구)

  • 이채욱;오신범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5C
    • /
    • pp.673-682
    • /
    • 2004
  • The adaptive beam-forming is promising approach for noise reduction in hearing aids. This approach has come in the focus of interest only recently, because of the availability of new and powerful digital signal processors. The adaptation U using usually a Least Mean Squares algorithm, updates the weight vector. In this Paper, we propose a fast wavelet based adaptive algorithm using variable step size algorithm which varies adaptive constant by the change of signal environment. We compared the performance of the proposed algorithm with the known adaptive algorithm using computer simulation of multi channel adaptive bemformer in hearing aids. As the result the proposed algorithm is suitable for adaptive signal processing area using hearing aids and has advantages reducing computational complexity. And we show the beam-forming system using proposed algorithm converges stably in a sudden change of system environment.

Chemical and Crystalline Properties of Polyimide Film Deposited by Ionized Cluster Beam (Ionizied Cluster Beam 방법으로 제작된 Polyimide 박막의 화학적 성질과 결정성)

  • K.W. Kim;S.C. Choi;S.S. Kim;S.J. Cho;S.Y. Hong;K.H. Jeong;J.N. Whang
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.139-144
    • /
    • 1992
  • Abstract-Polyimide (PI) thin films were deposited by the ionized cluster beam deposition (ICBD) technique. Imidization and crystallization of PI films were investigated using transmission electron microscopy (TEM) and Fourier transform infrared spectroscopy (FT-IR). PI films deposited under optimum conditions showed a maximum imidization and good crystal structure, which are superior to those of the films fabricated by other techniques.

  • PDF